Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System
The increasing prevalence of antimicrobial resistance is a serious threat to global public health. One of the most concerning trends is the rapid spread of Carbapenemase-Producing Organisms (CPO), where colistin has become the last-resort antibiotic treatment. The emergence of colistin resistance, i...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7242339/ https://www.ncbi.nlm.nih.gov/pubmed/32439986 http://dx.doi.org/10.1038/s41598-020-64612-1 |
_version_ | 1783537218746318848 |
---|---|
author | Rodriguez-Manzano, Jesus Moser, Nicolas Malpartida-Cardenas, Kenny Moniri, Ahmad Fisarova, Lenka Pennisi, Ivana Boonyasiri, Adhiratha Jauneikaite, Elita Abdolrasouli, Alireza Otter, Jonathan A. Bolt, Frances Davies, Frances Didelot, Xavier Holmes, Alison Georgiou, Pantelis |
author_facet | Rodriguez-Manzano, Jesus Moser, Nicolas Malpartida-Cardenas, Kenny Moniri, Ahmad Fisarova, Lenka Pennisi, Ivana Boonyasiri, Adhiratha Jauneikaite, Elita Abdolrasouli, Alireza Otter, Jonathan A. Bolt, Frances Davies, Frances Didelot, Xavier Holmes, Alison Georgiou, Pantelis |
author_sort | Rodriguez-Manzano, Jesus |
collection | PubMed |
description | The increasing prevalence of antimicrobial resistance is a serious threat to global public health. One of the most concerning trends is the rapid spread of Carbapenemase-Producing Organisms (CPO), where colistin has become the last-resort antibiotic treatment. The emergence of colistin resistance, including the spread of mobilized colistin resistance (mcr) genes, raises the possibility of untreatable bacterial infections and motivates the development of improved diagnostics for the detection of colistin-resistant organisms. This work demonstrates a rapid response for detecting the most recently reported mcr gene, mcr−9, using a portable and affordable lab-on-a-chip (LoC) platform, offering a promising alternative to conventional laboratory-based instruments such as real-time PCR (qPCR). The platform combines semiconductor technology, for non-optical real-time DNA sensing, with a smartphone application for data acquisition, visualization and cloud connectivity. This technology is enabled by using loop-mediated isothermal amplification (LAMP) as the chemistry for targeted DNA detection, by virtue of its high sensitivity, specificity, yield, and manageable temperature requirements. Here, we have developed the first LAMP assay for mcr−9 - showing high sensitivity (down to 100 genomic copies/reaction) and high specificity (no cross-reactivity with other mcr variants). This assay is demonstrated through supporting a hospital investigation where we analyzed nucleic acids extracted from 128 carbapenemase-producing bacteria isolated from clinical and screening samples and found that 41 carried mcr−9 (validated using whole genome sequencing). Average positive detection times were 6.58 ± 0.42 min when performing the experiments on a conventional qPCR instrument (n = 41). For validating the translation of the LAMP assay onto a LoC platform, a subset of the samples were tested (n = 20), showing average detection times of 6.83 ± 0.92 min for positive isolates (n = 14). All experiments detected mcr−9 in under 10 min, and both platforms showed no statistically significant difference (p-value > 0.05). When sample preparation and throughput capabilities are integrated within this LoC platform, the adoption of this technology for the rapid detection and surveillance of antimicrobial resistance genes will decrease the turnaround time for DNA detection and resistotyping, improving diagnostic capabilities, patient outcomes, and the management of infectious diseases. |
format | Online Article Text |
id | pubmed-7242339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-72423392020-05-29 Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System Rodriguez-Manzano, Jesus Moser, Nicolas Malpartida-Cardenas, Kenny Moniri, Ahmad Fisarova, Lenka Pennisi, Ivana Boonyasiri, Adhiratha Jauneikaite, Elita Abdolrasouli, Alireza Otter, Jonathan A. Bolt, Frances Davies, Frances Didelot, Xavier Holmes, Alison Georgiou, Pantelis Sci Rep Article The increasing prevalence of antimicrobial resistance is a serious threat to global public health. One of the most concerning trends is the rapid spread of Carbapenemase-Producing Organisms (CPO), where colistin has become the last-resort antibiotic treatment. The emergence of colistin resistance, including the spread of mobilized colistin resistance (mcr) genes, raises the possibility of untreatable bacterial infections and motivates the development of improved diagnostics for the detection of colistin-resistant organisms. This work demonstrates a rapid response for detecting the most recently reported mcr gene, mcr−9, using a portable and affordable lab-on-a-chip (LoC) platform, offering a promising alternative to conventional laboratory-based instruments such as real-time PCR (qPCR). The platform combines semiconductor technology, for non-optical real-time DNA sensing, with a smartphone application for data acquisition, visualization and cloud connectivity. This technology is enabled by using loop-mediated isothermal amplification (LAMP) as the chemistry for targeted DNA detection, by virtue of its high sensitivity, specificity, yield, and manageable temperature requirements. Here, we have developed the first LAMP assay for mcr−9 - showing high sensitivity (down to 100 genomic copies/reaction) and high specificity (no cross-reactivity with other mcr variants). This assay is demonstrated through supporting a hospital investigation where we analyzed nucleic acids extracted from 128 carbapenemase-producing bacteria isolated from clinical and screening samples and found that 41 carried mcr−9 (validated using whole genome sequencing). Average positive detection times were 6.58 ± 0.42 min when performing the experiments on a conventional qPCR instrument (n = 41). For validating the translation of the LAMP assay onto a LoC platform, a subset of the samples were tested (n = 20), showing average detection times of 6.83 ± 0.92 min for positive isolates (n = 14). All experiments detected mcr−9 in under 10 min, and both platforms showed no statistically significant difference (p-value > 0.05). When sample preparation and throughput capabilities are integrated within this LoC platform, the adoption of this technology for the rapid detection and surveillance of antimicrobial resistance genes will decrease the turnaround time for DNA detection and resistotyping, improving diagnostic capabilities, patient outcomes, and the management of infectious diseases. Nature Publishing Group UK 2020-05-21 /pmc/articles/PMC7242339/ /pubmed/32439986 http://dx.doi.org/10.1038/s41598-020-64612-1 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Rodriguez-Manzano, Jesus Moser, Nicolas Malpartida-Cardenas, Kenny Moniri, Ahmad Fisarova, Lenka Pennisi, Ivana Boonyasiri, Adhiratha Jauneikaite, Elita Abdolrasouli, Alireza Otter, Jonathan A. Bolt, Frances Davies, Frances Didelot, Xavier Holmes, Alison Georgiou, Pantelis Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title | Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title_full | Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title_fullStr | Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title_full_unstemmed | Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title_short | Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System |
title_sort | rapid detection of mobilized colistin resistance using a nucleic acid based lab-on-a-chip diagnostic system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7242339/ https://www.ncbi.nlm.nih.gov/pubmed/32439986 http://dx.doi.org/10.1038/s41598-020-64612-1 |
work_keys_str_mv | AT rodriguezmanzanojesus rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT mosernicolas rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT malpartidacardenaskenny rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT moniriahmad rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT fisarovalenka rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT pennisiivana rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT boonyasiriadhiratha rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT jauneikaiteelita rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT abdolrasoulialireza rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT otterjonathana rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT boltfrances rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT daviesfrances rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT didelotxavier rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT holmesalison rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem AT georgioupantelis rapiddetectionofmobilizedcolistinresistanceusinganucleicacidbasedlabonachipdiagnosticsystem |