Cargando…

Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review

Background: Although pericardial effusion/cardiac tamponade (PCE/CT) is a rare complication of peripherally inserted central catheters (PICCs), with an incidence of 0. 07–2%, it is associated with high mortality and is often life threatening. We sought to improve understanding of PICC-induced PCE/CT...

Descripción completa

Detalles Bibliográficos
Autores principales: Hou, Ana, Fu, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7242726/
https://www.ncbi.nlm.nih.gov/pubmed/32500049
http://dx.doi.org/10.3389/fped.2020.00235
_version_ 1783537283970891776
author Hou, Ana
Fu, Jianhua
author_facet Hou, Ana
Fu, Jianhua
author_sort Hou, Ana
collection PubMed
description Background: Although pericardial effusion/cardiac tamponade (PCE/CT) is a rare complication of peripherally inserted central catheters (PICCs), with an incidence of 0. 07–2%, it is associated with high mortality and is often life threatening. We sought to improve understanding of PICC-induced PCE/CT among pediatricians. Case presentation: The clinical data of PICC-associated PCE/CT in a very low birth weight (VLBW) infant were summarized, and the relevant literature was also reviewed. Conclusions: In VLBW infants with a PICC, if unstable respiratory circulatory system states are observed that cannot be explained, such as tachycardia, bradycardia, apnea, hypotension, and metabolic acidosis, PICC-induced PCE/CT should be considered. Early diagnosis and pericardial puncture are key to saving infants' lives.
format Online
Article
Text
id pubmed-7242726
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-72427262020-06-03 Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review Hou, Ana Fu, Jianhua Front Pediatr Pediatrics Background: Although pericardial effusion/cardiac tamponade (PCE/CT) is a rare complication of peripherally inserted central catheters (PICCs), with an incidence of 0. 07–2%, it is associated with high mortality and is often life threatening. We sought to improve understanding of PICC-induced PCE/CT among pediatricians. Case presentation: The clinical data of PICC-associated PCE/CT in a very low birth weight (VLBW) infant were summarized, and the relevant literature was also reviewed. Conclusions: In VLBW infants with a PICC, if unstable respiratory circulatory system states are observed that cannot be explained, such as tachycardia, bradycardia, apnea, hypotension, and metabolic acidosis, PICC-induced PCE/CT should be considered. Early diagnosis and pericardial puncture are key to saving infants' lives. Frontiers Media S.A. 2020-05-15 /pmc/articles/PMC7242726/ /pubmed/32500049 http://dx.doi.org/10.3389/fped.2020.00235 Text en Copyright © 2020 Hou and Fu. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Hou, Ana
Fu, Jianhua
Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title_full Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title_fullStr Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title_full_unstemmed Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title_short Pericardial Effusion/Cardiac Tamponade Induced by Peripherally Inserted Central Catheters in Very Low Birth Weight Infants: A Case Report and Literature Review
title_sort pericardial effusion/cardiac tamponade induced by peripherally inserted central catheters in very low birth weight infants: a case report and literature review
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7242726/
https://www.ncbi.nlm.nih.gov/pubmed/32500049
http://dx.doi.org/10.3389/fped.2020.00235
work_keys_str_mv AT houana pericardialeffusioncardiactamponadeinducedbyperipherallyinsertedcentralcathetersinverylowbirthweightinfantsacasereportandliteraturereview
AT fujianhua pericardialeffusioncardiactamponadeinducedbyperipherallyinsertedcentralcathetersinverylowbirthweightinfantsacasereportandliteraturereview