The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty

BACKGROUND: The failure of porous tantalum rods applied to patients with osteonecrosis of the femoral head (ONFH) has been increasingly reported during the last few years. Very few studies have reported methods for implant removal. This study aimed at comparing 2 procedures used for the removal of a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Fengchao, Zheng, Li, Cheng, Qi, Hu, Weifan, Wang, Bailiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7245062/
https://www.ncbi.nlm.nih.gov/pubmed/32404862
http://dx.doi.org/10.12659/MSM.921459
_version_ 1783537687671603200
author Zhao, Fengchao
Zheng, Li
Cheng, Qi
Hu, Weifan
Wang, Bailiang
author_facet Zhao, Fengchao
Zheng, Li
Cheng, Qi
Hu, Weifan
Wang, Bailiang
author_sort Zhao, Fengchao
collection PubMed
description BACKGROUND: The failure of porous tantalum rods applied to patients with osteonecrosis of the femoral head (ONFH) has been increasingly reported during the last few years. Very few studies have reported methods for implant removal. This study aimed at comparing 2 procedures used for the removal of a failed tantalum rod during conversion to total hip arthroplasty (THA). MATERIAL/METHODS: A total of 65 patients (65 hips), who underwent THA after failed implantation of a tantalum rod between June 2007 and December 2016, were retrospectively evaluated. These patients were classified into 2 groups depending on whether the antegrade approach (removal of the tantalum rod from the tip to the butt at the lateral femoral cortex, n=27) or retrograde approach (removal of the tantalum rod from the butt at the lateral femoral cortex to the proximal tip, n=38) was used for rod extraction. These 2 groups were compared for incision length, operation time, blood loss, fracture, tantalum debris, Harris hip scores, and the presence of osteolysis and/or radiolucency. RESULTS: These 2 groups did not present any significant differences in terms of Harris hip score and incision length. However, the operation time (P=0.000), blood loss (P=0.000), amount of tantalum debris (P=0.000), and presence of radiolucency (P=0.046) were greater for the retrograde approach than for the antegrade approach. CONCLUSIONS: The risk of conversion to THA following failed tantalum rod implantation is high. In such cases, the antegrade procedure was found to be a simple and efficient method for removing the trabecular metal rod with the use of a trephine.
format Online
Article
Text
id pubmed-7245062
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-72450622020-06-01 The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty Zhao, Fengchao Zheng, Li Cheng, Qi Hu, Weifan Wang, Bailiang Med Sci Monit Clinical Research BACKGROUND: The failure of porous tantalum rods applied to patients with osteonecrosis of the femoral head (ONFH) has been increasingly reported during the last few years. Very few studies have reported methods for implant removal. This study aimed at comparing 2 procedures used for the removal of a failed tantalum rod during conversion to total hip arthroplasty (THA). MATERIAL/METHODS: A total of 65 patients (65 hips), who underwent THA after failed implantation of a tantalum rod between June 2007 and December 2016, were retrospectively evaluated. These patients were classified into 2 groups depending on whether the antegrade approach (removal of the tantalum rod from the tip to the butt at the lateral femoral cortex, n=27) or retrograde approach (removal of the tantalum rod from the butt at the lateral femoral cortex to the proximal tip, n=38) was used for rod extraction. These 2 groups were compared for incision length, operation time, blood loss, fracture, tantalum debris, Harris hip scores, and the presence of osteolysis and/or radiolucency. RESULTS: These 2 groups did not present any significant differences in terms of Harris hip score and incision length. However, the operation time (P=0.000), blood loss (P=0.000), amount of tantalum debris (P=0.000), and presence of radiolucency (P=0.046) were greater for the retrograde approach than for the antegrade approach. CONCLUSIONS: The risk of conversion to THA following failed tantalum rod implantation is high. In such cases, the antegrade procedure was found to be a simple and efficient method for removing the trabecular metal rod with the use of a trephine. International Scientific Literature, Inc. 2020-05-14 /pmc/articles/PMC7245062/ /pubmed/32404862 http://dx.doi.org/10.12659/MSM.921459 Text en © Med Sci Monit, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Zhao, Fengchao
Zheng, Li
Cheng, Qi
Hu, Weifan
Wang, Bailiang
The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title_full The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title_fullStr The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title_full_unstemmed The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title_short The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty
title_sort comparative analysis of antegrade versus retrograde approach for a failed porous tantalum rod removal during conversion to total hip arthroplasty
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7245062/
https://www.ncbi.nlm.nih.gov/pubmed/32404862
http://dx.doi.org/10.12659/MSM.921459
work_keys_str_mv AT zhaofengchao thecomparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT zhengli thecomparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT chengqi thecomparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT huweifan thecomparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT wangbailiang thecomparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT zhaofengchao comparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT zhengli comparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT chengqi comparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT huweifan comparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty
AT wangbailiang comparativeanalysisofantegradeversusretrogradeapproachforafailedporoustantalumrodremovalduringconversiontototalhiparthroplasty