Cargando…
Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Syste...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246067/ https://www.ncbi.nlm.nih.gov/pubmed/31927580 http://dx.doi.org/10.1093/jrr/rrz082 |
_version_ | 1783537874284576768 |
---|---|
author | Isono, Masaru Akino, Yuichi Mizuno, Hirokazu Tanaka, Yoshihiro Masai, Norihisa Yamamoto, Toshijiro |
author_facet | Isono, Masaru Akino, Yuichi Mizuno, Hirokazu Tanaka, Yoshihiro Masai, Norihisa Yamamoto, Toshijiro |
author_sort | Isono, Masaru |
collection | PubMed |
description | Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Systems) treatment planning system. However, RBD does not provide multi-leaf collimator (MLC) parameters, such as MLC leaf transmission factor (LTF) and dosimetric leaf gap (DLG). We performed a web-based multi-institutional survey to investigate these parameters as well as the measurement protocols and customization of the parameters for intensity-modulated radiotherapy (IMRT) and/or volumetric modulated radiotherapy (VMAT) commissioning. We collected 69 sets of linear accelerator (linac) data from 58 institutions. In order to measure MLC parameters, most institutions used farmer-type ionization chambers with a sensitive volume of 0.6 cm(3), water phantoms, source surface distance of 90 cm with 10 cm depth, and a vendor-provided plan. The LTF showed small inter-unit variabilities, although the DLG showed large variations. For optimization of the parameters for IMRT/VMAT calculations, DLG values were upwardly adjusted at many institutions, whereas the LTF values were modestly changed. We clarified that MLC parameters were measured under the same conditions at more than half of the facilities. Most institutions customized parameters in a similar manner for IMRT/VMAT. The median measured and customized values obtained in our study will be valuable to verify MLC installation accuracy and to shorten the iterative processes of finding the optimal values. |
format | Online Article Text |
id | pubmed-7246067 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-72460672020-05-28 Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey Isono, Masaru Akino, Yuichi Mizuno, Hirokazu Tanaka, Yoshihiro Masai, Norihisa Yamamoto, Toshijiro J Radiat Res Regular Paper Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Systems) treatment planning system. However, RBD does not provide multi-leaf collimator (MLC) parameters, such as MLC leaf transmission factor (LTF) and dosimetric leaf gap (DLG). We performed a web-based multi-institutional survey to investigate these parameters as well as the measurement protocols and customization of the parameters for intensity-modulated radiotherapy (IMRT) and/or volumetric modulated radiotherapy (VMAT) commissioning. We collected 69 sets of linear accelerator (linac) data from 58 institutions. In order to measure MLC parameters, most institutions used farmer-type ionization chambers with a sensitive volume of 0.6 cm(3), water phantoms, source surface distance of 90 cm with 10 cm depth, and a vendor-provided plan. The LTF showed small inter-unit variabilities, although the DLG showed large variations. For optimization of the parameters for IMRT/VMAT calculations, DLG values were upwardly adjusted at many institutions, whereas the LTF values were modestly changed. We clarified that MLC parameters were measured under the same conditions at more than half of the facilities. Most institutions customized parameters in a similar manner for IMRT/VMAT. The median measured and customized values obtained in our study will be valuable to verify MLC installation accuracy and to shorten the iterative processes of finding the optimal values. Oxford University Press 2020-01-11 /pmc/articles/PMC7246067/ /pubmed/31927580 http://dx.doi.org/10.1093/jrr/rrz082 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Regular Paper Isono, Masaru Akino, Yuichi Mizuno, Hirokazu Tanaka, Yoshihiro Masai, Norihisa Yamamoto, Toshijiro Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title | Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title_full | Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title_fullStr | Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title_full_unstemmed | Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title_short | Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey |
title_sort | inter-unit variability of multi-leaf collimator parameters for imrt and vmat treatment planning: a multi-institutional survey |
topic | Regular Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246067/ https://www.ncbi.nlm.nih.gov/pubmed/31927580 http://dx.doi.org/10.1093/jrr/rrz082 |
work_keys_str_mv | AT isonomasaru interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey AT akinoyuichi interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey AT mizunohirokazu interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey AT tanakayoshihiro interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey AT masainorihisa interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey AT yamamototoshijiro interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey |