Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey

Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Syste...

Descripción completa

Detalles Bibliográficos
Autores principales: Isono, Masaru, Akino, Yuichi, Mizuno, Hirokazu, Tanaka, Yoshihiro, Masai, Norihisa, Yamamoto, Toshijiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246067/
https://www.ncbi.nlm.nih.gov/pubmed/31927580
http://dx.doi.org/10.1093/jrr/rrz082
_version_ 1783537874284576768
author Isono, Masaru
Akino, Yuichi
Mizuno, Hirokazu
Tanaka, Yoshihiro
Masai, Norihisa
Yamamoto, Toshijiro
author_facet Isono, Masaru
Akino, Yuichi
Mizuno, Hirokazu
Tanaka, Yoshihiro
Masai, Norihisa
Yamamoto, Toshijiro
author_sort Isono, Masaru
collection PubMed
description Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Systems) treatment planning system. However, RBD does not provide multi-leaf collimator (MLC) parameters, such as MLC leaf transmission factor (LTF) and dosimetric leaf gap (DLG). We performed a web-based multi-institutional survey to investigate these parameters as well as the measurement protocols and customization of the parameters for intensity-modulated radiotherapy (IMRT) and/or volumetric modulated radiotherapy (VMAT) commissioning. We collected 69 sets of linear accelerator (linac) data from 58 institutions. In order to measure MLC parameters, most institutions used farmer-type ionization chambers with a sensitive volume of 0.6 cm(3), water phantoms, source surface distance of 90 cm with 10 cm depth, and a vendor-provided plan. The LTF showed small inter-unit variabilities, although the DLG showed large variations. For optimization of the parameters for IMRT/VMAT calculations, DLG values were upwardly adjusted at many institutions, whereas the LTF values were modestly changed. We clarified that MLC parameters were measured under the same conditions at more than half of the facilities. Most institutions customized parameters in a similar manner for IMRT/VMAT. The median measured and customized values obtained in our study will be valuable to verify MLC installation accuracy and to shorten the iterative processes of finding the optimal values.
format Online
Article
Text
id pubmed-7246067
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-72460672020-05-28 Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey Isono, Masaru Akino, Yuichi Mizuno, Hirokazu Tanaka, Yoshihiro Masai, Norihisa Yamamoto, Toshijiro J Radiat Res Regular Paper Modern treatment machines have shown small inter-unit variability regarding beam data. Recently, vendor-provided average beam data, such as the Representative Beam Data (RBD) of the TrueBeam (Varian Medical Systems, Palo Alto, CA, USA), has been used for modeling of the Eclipse (Varian Medical Systems) treatment planning system. However, RBD does not provide multi-leaf collimator (MLC) parameters, such as MLC leaf transmission factor (LTF) and dosimetric leaf gap (DLG). We performed a web-based multi-institutional survey to investigate these parameters as well as the measurement protocols and customization of the parameters for intensity-modulated radiotherapy (IMRT) and/or volumetric modulated radiotherapy (VMAT) commissioning. We collected 69 sets of linear accelerator (linac) data from 58 institutions. In order to measure MLC parameters, most institutions used farmer-type ionization chambers with a sensitive volume of 0.6 cm(3), water phantoms, source surface distance of 90 cm with 10 cm depth, and a vendor-provided plan. The LTF showed small inter-unit variabilities, although the DLG showed large variations. For optimization of the parameters for IMRT/VMAT calculations, DLG values were upwardly adjusted at many institutions, whereas the LTF values were modestly changed. We clarified that MLC parameters were measured under the same conditions at more than half of the facilities. Most institutions customized parameters in a similar manner for IMRT/VMAT. The median measured and customized values obtained in our study will be valuable to verify MLC installation accuracy and to shorten the iterative processes of finding the optimal values. Oxford University Press 2020-01-11 /pmc/articles/PMC7246067/ /pubmed/31927580 http://dx.doi.org/10.1093/jrr/rrz082 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regular Paper
Isono, Masaru
Akino, Yuichi
Mizuno, Hirokazu
Tanaka, Yoshihiro
Masai, Norihisa
Yamamoto, Toshijiro
Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title_full Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title_fullStr Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title_full_unstemmed Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title_short Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey
title_sort inter-unit variability of multi-leaf collimator parameters for imrt and vmat treatment planning: a multi-institutional survey
topic Regular Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246067/
https://www.ncbi.nlm.nih.gov/pubmed/31927580
http://dx.doi.org/10.1093/jrr/rrz082
work_keys_str_mv AT isonomasaru interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey
AT akinoyuichi interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey
AT mizunohirokazu interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey
AT tanakayoshihiro interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey
AT masainorihisa interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey
AT yamamototoshijiro interunitvariabilityofmultileafcollimatorparametersforimrtandvmattreatmentplanningamultiinstitutionalsurvey