Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246393/ https://www.ncbi.nlm.nih.gov/pubmed/32509343 http://dx.doi.org/10.1155/2020/8946364 |
_version_ | 1783537935507783680 |
---|---|
author | Huang, Jinhai Zhao, Yuyu Savini, Giacomo Yu, Guanshun Yu, Jinjin Chen, Zhongxing Tu, Ruixue Zhao, Yune |
author_facet | Huang, Jinhai Zhao, Yuyu Savini, Giacomo Yu, Guanshun Yu, Jinjin Chen, Zhongxing Tu, Ruixue Zhao, Yune |
author_sort | Huang, Jinhai |
collection | PubMed |
description | PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland–Altman method. RESULTS: The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27–0.44 mm; ICC, 0.86–0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 μm, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 μm, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. CONCLUSION: Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients. |
format | Online Article Text |
id | pubmed-7246393 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-72463932020-06-06 Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients Huang, Jinhai Zhao, Yuyu Savini, Giacomo Yu, Guanshun Yu, Jinjin Chen, Zhongxing Tu, Ruixue Zhao, Yune J Ophthalmol Research Article PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland–Altman method. RESULTS: The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27–0.44 mm; ICC, 0.86–0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 μm, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 μm, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. CONCLUSION: Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients. Hindawi 2020-05-15 /pmc/articles/PMC7246393/ /pubmed/32509343 http://dx.doi.org/10.1155/2020/8946364 Text en Copyright © 2020 Jinhai Huang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Huang, Jinhai Zhao, Yuyu Savini, Giacomo Yu, Guanshun Yu, Jinjin Chen, Zhongxing Tu, Ruixue Zhao, Yune Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title | Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title_full | Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title_fullStr | Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title_full_unstemmed | Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title_short | Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients |
title_sort | reliability of a new swept-source optical coherence tomography biometer in healthy children, adults, and cataract patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246393/ https://www.ncbi.nlm.nih.gov/pubmed/32509343 http://dx.doi.org/10.1155/2020/8946364 |
work_keys_str_mv | AT huangjinhai reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT zhaoyuyu reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT savinigiacomo reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT yuguanshun reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT yujinjin reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT chenzhongxing reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT turuixue reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients AT zhaoyune reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients |