Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients

PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Jinhai, Zhao, Yuyu, Savini, Giacomo, Yu, Guanshun, Yu, Jinjin, Chen, Zhongxing, Tu, Ruixue, Zhao, Yune
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246393/
https://www.ncbi.nlm.nih.gov/pubmed/32509343
http://dx.doi.org/10.1155/2020/8946364
_version_ 1783537935507783680
author Huang, Jinhai
Zhao, Yuyu
Savini, Giacomo
Yu, Guanshun
Yu, Jinjin
Chen, Zhongxing
Tu, Ruixue
Zhao, Yune
author_facet Huang, Jinhai
Zhao, Yuyu
Savini, Giacomo
Yu, Guanshun
Yu, Jinjin
Chen, Zhongxing
Tu, Ruixue
Zhao, Yune
author_sort Huang, Jinhai
collection PubMed
description PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland–Altman method. RESULTS: The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27–0.44 mm; ICC, 0.86–0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 μm, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 μm, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. CONCLUSION: Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients.
format Online
Article
Text
id pubmed-7246393
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-72463932020-06-06 Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients Huang, Jinhai Zhao, Yuyu Savini, Giacomo Yu, Guanshun Yu, Jinjin Chen, Zhongxing Tu, Ruixue Zhao, Yune J Ophthalmol Research Article PURPOSE: To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. METHODS: A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland–Altman method. RESULTS: The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27–0.44 mm; ICC, 0.86–0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 μm, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 μm, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. CONCLUSION: Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients. Hindawi 2020-05-15 /pmc/articles/PMC7246393/ /pubmed/32509343 http://dx.doi.org/10.1155/2020/8946364 Text en Copyright © 2020 Jinhai Huang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Jinhai
Zhao, Yuyu
Savini, Giacomo
Yu, Guanshun
Yu, Jinjin
Chen, Zhongxing
Tu, Ruixue
Zhao, Yune
Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title_full Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title_fullStr Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title_full_unstemmed Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title_short Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients
title_sort reliability of a new swept-source optical coherence tomography biometer in healthy children, adults, and cataract patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246393/
https://www.ncbi.nlm.nih.gov/pubmed/32509343
http://dx.doi.org/10.1155/2020/8946364
work_keys_str_mv AT huangjinhai reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT zhaoyuyu reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT savinigiacomo reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT yuguanshun reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT yujinjin reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT chenzhongxing reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT turuixue reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients
AT zhaoyune reliabilityofanewsweptsourceopticalcoherencetomographybiometerinhealthychildrenadultsandcataractpatients