Biological Monitoring of Metal Ions Released from Hip Prostheses
The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), grou...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246585/ https://www.ncbi.nlm.nih.gov/pubmed/32384733 http://dx.doi.org/10.3390/ijerph17093223 |
_version_ | 1783537980877570048 |
---|---|
author | Nicolli, Annamaria Trevisan, Andrea Bortoletti, Isabella Pozzuoli, Assunta Ruggieri, Pietro Martinelli, Andrea Gambalunga, Alberto Carrieri, Mariella |
author_facet | Nicolli, Annamaria Trevisan, Andrea Bortoletti, Isabella Pozzuoli, Assunta Ruggieri, Pietro Martinelli, Andrea Gambalunga, Alberto Carrieri, Mariella |
author_sort | Nicolli, Annamaria |
collection | PubMed |
description | The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), group A, 25 patients; total Met-Met System Lima(®), group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals. |
format | Online Article Text |
id | pubmed-7246585 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72465852020-06-10 Biological Monitoring of Metal Ions Released from Hip Prostheses Nicolli, Annamaria Trevisan, Andrea Bortoletti, Isabella Pozzuoli, Assunta Ruggieri, Pietro Martinelli, Andrea Gambalunga, Alberto Carrieri, Mariella Int J Environ Res Public Health Article The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), group A, 25 patients; total Met-Met System Lima(®), group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals. MDPI 2020-05-06 2020-05 /pmc/articles/PMC7246585/ /pubmed/32384733 http://dx.doi.org/10.3390/ijerph17093223 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nicolli, Annamaria Trevisan, Andrea Bortoletti, Isabella Pozzuoli, Assunta Ruggieri, Pietro Martinelli, Andrea Gambalunga, Alberto Carrieri, Mariella Biological Monitoring of Metal Ions Released from Hip Prostheses |
title | Biological Monitoring of Metal Ions Released from Hip Prostheses |
title_full | Biological Monitoring of Metal Ions Released from Hip Prostheses |
title_fullStr | Biological Monitoring of Metal Ions Released from Hip Prostheses |
title_full_unstemmed | Biological Monitoring of Metal Ions Released from Hip Prostheses |
title_short | Biological Monitoring of Metal Ions Released from Hip Prostheses |
title_sort | biological monitoring of metal ions released from hip prostheses |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246585/ https://www.ncbi.nlm.nih.gov/pubmed/32384733 http://dx.doi.org/10.3390/ijerph17093223 |
work_keys_str_mv | AT nicolliannamaria biologicalmonitoringofmetalionsreleasedfromhipprostheses AT trevisanandrea biologicalmonitoringofmetalionsreleasedfromhipprostheses AT bortolettiisabella biologicalmonitoringofmetalionsreleasedfromhipprostheses AT pozzuoliassunta biologicalmonitoringofmetalionsreleasedfromhipprostheses AT ruggieripietro biologicalmonitoringofmetalionsreleasedfromhipprostheses AT martinelliandrea biologicalmonitoringofmetalionsreleasedfromhipprostheses AT gambalungaalberto biologicalmonitoringofmetalionsreleasedfromhipprostheses AT carrierimariella biologicalmonitoringofmetalionsreleasedfromhipprostheses |