Biological Monitoring of Metal Ions Released from Hip Prostheses

The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), grou...

Descripción completa

Detalles Bibliográficos
Autores principales: Nicolli, Annamaria, Trevisan, Andrea, Bortoletti, Isabella, Pozzuoli, Assunta, Ruggieri, Pietro, Martinelli, Andrea, Gambalunga, Alberto, Carrieri, Mariella
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246585/
https://www.ncbi.nlm.nih.gov/pubmed/32384733
http://dx.doi.org/10.3390/ijerph17093223
_version_ 1783537980877570048
author Nicolli, Annamaria
Trevisan, Andrea
Bortoletti, Isabella
Pozzuoli, Assunta
Ruggieri, Pietro
Martinelli, Andrea
Gambalunga, Alberto
Carrieri, Mariella
author_facet Nicolli, Annamaria
Trevisan, Andrea
Bortoletti, Isabella
Pozzuoli, Assunta
Ruggieri, Pietro
Martinelli, Andrea
Gambalunga, Alberto
Carrieri, Mariella
author_sort Nicolli, Annamaria
collection PubMed
description The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), group A, 25 patients; total Met-Met System Lima(®), group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals.
format Online
Article
Text
id pubmed-7246585
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72465852020-06-10 Biological Monitoring of Metal Ions Released from Hip Prostheses Nicolli, Annamaria Trevisan, Andrea Bortoletti, Isabella Pozzuoli, Assunta Ruggieri, Pietro Martinelli, Andrea Gambalunga, Alberto Carrieri, Mariella Int J Environ Res Public Health Article The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy(®), group A, 25 patients; total Met-Met System Lima(®), group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals. MDPI 2020-05-06 2020-05 /pmc/articles/PMC7246585/ /pubmed/32384733 http://dx.doi.org/10.3390/ijerph17093223 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nicolli, Annamaria
Trevisan, Andrea
Bortoletti, Isabella
Pozzuoli, Assunta
Ruggieri, Pietro
Martinelli, Andrea
Gambalunga, Alberto
Carrieri, Mariella
Biological Monitoring of Metal Ions Released from Hip Prostheses
title Biological Monitoring of Metal Ions Released from Hip Prostheses
title_full Biological Monitoring of Metal Ions Released from Hip Prostheses
title_fullStr Biological Monitoring of Metal Ions Released from Hip Prostheses
title_full_unstemmed Biological Monitoring of Metal Ions Released from Hip Prostheses
title_short Biological Monitoring of Metal Ions Released from Hip Prostheses
title_sort biological monitoring of metal ions released from hip prostheses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7246585/
https://www.ncbi.nlm.nih.gov/pubmed/32384733
http://dx.doi.org/10.3390/ijerph17093223
work_keys_str_mv AT nicolliannamaria biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT trevisanandrea biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT bortolettiisabella biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT pozzuoliassunta biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT ruggieripietro biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT martinelliandrea biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT gambalungaalberto biologicalmonitoringofmetalionsreleasedfromhipprostheses
AT carrierimariella biologicalmonitoringofmetalionsreleasedfromhipprostheses