Cargando…

Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))

BACKGROUND: Considering the excellent results already achieved in total hip arthroplasty (THA), new implants must be at least as safe as currently used implants and lead to longer survival. A new cementless femoral stem, SP-CL(®), has been introduced. The aim of this study is to evaluate intraoperat...

Descripción completa

Detalles Bibliográficos
Autores principales: Tootsi, Kaspar, Lees, Loviisa, Geiko, Boris, Märtson, Aare
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7248161/
https://www.ncbi.nlm.nih.gov/pubmed/32451636
http://dx.doi.org/10.1186/s10195-020-00548-6
_version_ 1783538308498849792
author Tootsi, Kaspar
Lees, Loviisa
Geiko, Boris
Märtson, Aare
author_facet Tootsi, Kaspar
Lees, Loviisa
Geiko, Boris
Märtson, Aare
author_sort Tootsi, Kaspar
collection PubMed
description BACKGROUND: Considering the excellent results already achieved in total hip arthroplasty (THA), new implants must be at least as safe as currently used implants and lead to longer survival. A new cementless femoral stem, SP-CL(®), has been introduced. The aim of this study is to evaluate intraoperative complications and assess the risk factors of THA with the SP-CL(®) implant. MATERIALS AND METHODS: All THA patients who were operated on using the SP-CL(®) (LINK, Hamburg, Germany) implant between 2015 and 2018 were included in the analysis. Data were collected from medical records from national and hospital electronic databases. Radiological measurements were made from standard pre- and postoperative radiographs. RESULTS: A total of 222 THA were performed using the SP-CL(®) implant. The average age of the patients was 56 years (14–77 years). There were 1 transient sciatic nerve injury, 1 acetabular fracture, and 11 (5.0%) intraoperative femoral fractures (IFF), of which 7 were treated with cerclage wire or titanium band during the operation while the other fractures were treated conservatively. None of the IFF patients were revised due to fracture during the follow-up period (one revision due to infection). The radiographic morphology of proximal femur was associated with increased risk of IFF (p = 0.02). CONCLUSIONS: The results of the current study demonstrate a 5% incidence of IFF when using the LINK SP-CL(®) femoral stem in THA. The radiographic morphology of the proximal femur was an important predictor of IFF and should be assessed when using SP-CL(®). LEVEL OF EVIDENCE: Level 4.
format Online
Article
Text
id pubmed-7248161
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-72481612020-06-05 Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®)) Tootsi, Kaspar Lees, Loviisa Geiko, Boris Märtson, Aare J Orthop Traumatol Original Article BACKGROUND: Considering the excellent results already achieved in total hip arthroplasty (THA), new implants must be at least as safe as currently used implants and lead to longer survival. A new cementless femoral stem, SP-CL(®), has been introduced. The aim of this study is to evaluate intraoperative complications and assess the risk factors of THA with the SP-CL(®) implant. MATERIALS AND METHODS: All THA patients who were operated on using the SP-CL(®) (LINK, Hamburg, Germany) implant between 2015 and 2018 were included in the analysis. Data were collected from medical records from national and hospital electronic databases. Radiological measurements were made from standard pre- and postoperative radiographs. RESULTS: A total of 222 THA were performed using the SP-CL(®) implant. The average age of the patients was 56 years (14–77 years). There were 1 transient sciatic nerve injury, 1 acetabular fracture, and 11 (5.0%) intraoperative femoral fractures (IFF), of which 7 were treated with cerclage wire or titanium band during the operation while the other fractures were treated conservatively. None of the IFF patients were revised due to fracture during the follow-up period (one revision due to infection). The radiographic morphology of proximal femur was associated with increased risk of IFF (p = 0.02). CONCLUSIONS: The results of the current study demonstrate a 5% incidence of IFF when using the LINK SP-CL(®) femoral stem in THA. The radiographic morphology of the proximal femur was an important predictor of IFF and should be assessed when using SP-CL(®). LEVEL OF EVIDENCE: Level 4. Springer International Publishing 2020-05-25 2020-12 /pmc/articles/PMC7248161/ /pubmed/32451636 http://dx.doi.org/10.1186/s10195-020-00548-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Tootsi, Kaspar
Lees, Loviisa
Geiko, Boris
Märtson, Aare
Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title_full Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title_fullStr Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title_full_unstemmed Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title_short Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(®))
title_sort intraoperative complications in total hip arthroplasty using a new cementless femoral implant (sp-cl(®))
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7248161/
https://www.ncbi.nlm.nih.gov/pubmed/32451636
http://dx.doi.org/10.1186/s10195-020-00548-6
work_keys_str_mv AT tootsikaspar intraoperativecomplicationsintotalhiparthroplastyusinganewcementlessfemoralimplantspcl
AT leesloviisa intraoperativecomplicationsintotalhiparthroplastyusinganewcementlessfemoralimplantspcl
AT geikoboris intraoperativecomplicationsintotalhiparthroplastyusinganewcementlessfemoralimplantspcl
AT martsonaare intraoperativecomplicationsintotalhiparthroplastyusinganewcementlessfemoralimplantspcl