Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interfer...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249211/ https://www.ncbi.nlm.nih.gov/pubmed/32392780 http://dx.doi.org/10.3390/s20092665 |
_version_ | 1783538551965614080 |
---|---|
author | Park, Soongho Lee, Juhyung Kim, Younggue Lee, Byeong Ha |
author_facet | Park, Soongho Lee, Juhyung Kim, Younggue Lee, Byeong Ha |
author_sort | Park, Soongho |
collection | PubMed |
description | We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interference signal could be reconstructed with two interference signals measured at two return ports of the coupler. The intrinsic phase difference between the return ports was utilized to obtain the quadratic part of the interference signal, which allowed one to reconstruct the entire complex interference signal. However, the two measured signals were appreciably affected by the unequal detector gains and non-uniform intrinsic phases of the coupler. Fortunately, we could find that the Lissajous curve plotted by the two signals of the interferometric system would form an ellipse. Therefore, by fitting the measured Lissajous curve to an ellipse, we could extract the parameters characterizing the actual system, which allowed the nanometer-scale measurement. Experimental results showed that a 20 kHz sinusoidal vibration with an amplitude of 1.5 nm could be measured with a standard deviation of 0.4 nm. |
format | Online Article Text |
id | pubmed-7249211 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72492112020-06-10 Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler Park, Soongho Lee, Juhyung Kim, Younggue Lee, Byeong Ha Sensors (Basel) Article We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interference signal could be reconstructed with two interference signals measured at two return ports of the coupler. The intrinsic phase difference between the return ports was utilized to obtain the quadratic part of the interference signal, which allowed one to reconstruct the entire complex interference signal. However, the two measured signals were appreciably affected by the unequal detector gains and non-uniform intrinsic phases of the coupler. Fortunately, we could find that the Lissajous curve plotted by the two signals of the interferometric system would form an ellipse. Therefore, by fitting the measured Lissajous curve to an ellipse, we could extract the parameters characterizing the actual system, which allowed the nanometer-scale measurement. Experimental results showed that a 20 kHz sinusoidal vibration with an amplitude of 1.5 nm could be measured with a standard deviation of 0.4 nm. MDPI 2020-05-07 /pmc/articles/PMC7249211/ /pubmed/32392780 http://dx.doi.org/10.3390/s20092665 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Soongho Lee, Juhyung Kim, Younggue Lee, Byeong Ha Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title | Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title_full | Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title_fullStr | Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title_full_unstemmed | Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title_short | Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler |
title_sort | nanometer-scale vibration measurement using an optical quadrature interferometer based on 3 × 3 fiber-optic coupler |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249211/ https://www.ncbi.nlm.nih.gov/pubmed/32392780 http://dx.doi.org/10.3390/s20092665 |
work_keys_str_mv | AT parksoongho nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler AT leejuhyung nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler AT kimyounggue nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler AT leebyeongha nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler |