Cargando…

Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler

We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interfer...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Soongho, Lee, Juhyung, Kim, Younggue, Lee, Byeong Ha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249211/
https://www.ncbi.nlm.nih.gov/pubmed/32392780
http://dx.doi.org/10.3390/s20092665
_version_ 1783538551965614080
author Park, Soongho
Lee, Juhyung
Kim, Younggue
Lee, Byeong Ha
author_facet Park, Soongho
Lee, Juhyung
Kim, Younggue
Lee, Byeong Ha
author_sort Park, Soongho
collection PubMed
description We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interference signal could be reconstructed with two interference signals measured at two return ports of the coupler. The intrinsic phase difference between the return ports was utilized to obtain the quadratic part of the interference signal, which allowed one to reconstruct the entire complex interference signal. However, the two measured signals were appreciably affected by the unequal detector gains and non-uniform intrinsic phases of the coupler. Fortunately, we could find that the Lissajous curve plotted by the two signals of the interferometric system would form an ellipse. Therefore, by fitting the measured Lissajous curve to an ellipse, we could extract the parameters characterizing the actual system, which allowed the nanometer-scale measurement. Experimental results showed that a 20 kHz sinusoidal vibration with an amplitude of 1.5 nm could be measured with a standard deviation of 0.4 nm.
format Online
Article
Text
id pubmed-7249211
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72492112020-06-10 Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler Park, Soongho Lee, Juhyung Kim, Younggue Lee, Byeong Ha Sensors (Basel) Article We propose a nanometer-scale displacement or vibration measurement system, using an optical quadrature interferometer and the post-processing technique that extracts the parameters necessary for characterizing the interferometric system. Using a 3 × 3 fiber-optic coupler, the entire complex interference signal could be reconstructed with two interference signals measured at two return ports of the coupler. The intrinsic phase difference between the return ports was utilized to obtain the quadratic part of the interference signal, which allowed one to reconstruct the entire complex interference signal. However, the two measured signals were appreciably affected by the unequal detector gains and non-uniform intrinsic phases of the coupler. Fortunately, we could find that the Lissajous curve plotted by the two signals of the interferometric system would form an ellipse. Therefore, by fitting the measured Lissajous curve to an ellipse, we could extract the parameters characterizing the actual system, which allowed the nanometer-scale measurement. Experimental results showed that a 20 kHz sinusoidal vibration with an amplitude of 1.5 nm could be measured with a standard deviation of 0.4 nm. MDPI 2020-05-07 /pmc/articles/PMC7249211/ /pubmed/32392780 http://dx.doi.org/10.3390/s20092665 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Soongho
Lee, Juhyung
Kim, Younggue
Lee, Byeong Ha
Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title_full Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title_fullStr Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title_full_unstemmed Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title_short Nanometer-Scale Vibration Measurement Using an Optical Quadrature Interferometer Based on 3 × 3 Fiber-Optic Coupler
title_sort nanometer-scale vibration measurement using an optical quadrature interferometer based on 3 × 3 fiber-optic coupler
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249211/
https://www.ncbi.nlm.nih.gov/pubmed/32392780
http://dx.doi.org/10.3390/s20092665
work_keys_str_mv AT parksoongho nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler
AT leejuhyung nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler
AT kimyounggue nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler
AT leebyeongha nanometerscalevibrationmeasurementusinganopticalquadratureinterferometerbasedon33fiberopticcoupler