Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting

Liquid-borne particles sampling and cantilever-based mass detection are widely applied in many industrial and scientific fields e.g., in the detection of physical, chemical, and biological particles, and disease diagnostics, etc. Microscopic analysis of particles-adsorbed cantilever-samples can prov...

Descripción completa

Detalles Bibliográficos
Autores principales: Nyang’au, Wilson Ombati, Setiono, Andi, Schmidt, Angelika, Bosse, Harald, Peiner, Erwin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249213/
https://www.ncbi.nlm.nih.gov/pubmed/32354176
http://dx.doi.org/10.3390/s20092508
_version_ 1783538552436424704
author Nyang’au, Wilson Ombati
Setiono, Andi
Schmidt, Angelika
Bosse, Harald
Peiner, Erwin
author_facet Nyang’au, Wilson Ombati
Setiono, Andi
Schmidt, Angelika
Bosse, Harald
Peiner, Erwin
author_sort Nyang’au, Wilson Ombati
collection PubMed
description Liquid-borne particles sampling and cantilever-based mass detection are widely applied in many industrial and scientific fields e.g., in the detection of physical, chemical, and biological particles, and disease diagnostics, etc. Microscopic analysis of particles-adsorbed cantilever-samples can provide a good basis for measurement comparison. However, when a particles-laden droplet on a solid surface is vaporized, a cluster-ring deposit is often yielded which makes particles counting difficult or impractical. Nevertheless, in this study, we present an approach, i.e., on-cantilever particles imprinting, which effectively defies such odds to sample and deposit countable single particles on a sensing surface. Initially, we designed and fabricated a triangular microcantilever sensor whose mass m(0), total beam-length L, and clamped-end beam-width w are equivalent to that of a rectangular/normal cantilever but with a higher resonant frequency (271 kHz), enhanced sensitivity (0.13 Hz/pg), and quality factor (~3000). To imprint particles on these cantilever sensors, various calibrated stainless steel dispensing tips were utilized to pioneer this study by dipping and retracting each tip from a small particle-laden droplet (resting on a hydrophobic n-type silicon substrate), followed by tip-sensor-contact (at a target point on the sensing area) to detach the solution (from the tip) and adsorb the particles, and ultimately determine the particles mass concentration. Upon imprinting/adsorbing the particles on the sensor, resonant frequency response measurements were made to determine the mass (or number of particles). A minimum detectable mass of ~0.05 pg was demonstrated. To further validate and compare such results, cantilever samples (containing adsorbed particles) were imaged by scanning electron microscopy (SEM) to determine the number of particles through counting (from which, the lowest count of about 11 magnetic polystyrene particles was obtained). The practicality of particle counting was essentially due to monolayer particle arrangement on the sensing surface. Moreover, in this work, the main measurement process influences are also explicitly examined.
format Online
Article
Text
id pubmed-7249213
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72492132020-06-10 Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting Nyang’au, Wilson Ombati Setiono, Andi Schmidt, Angelika Bosse, Harald Peiner, Erwin Sensors (Basel) Article Liquid-borne particles sampling and cantilever-based mass detection are widely applied in many industrial and scientific fields e.g., in the detection of physical, chemical, and biological particles, and disease diagnostics, etc. Microscopic analysis of particles-adsorbed cantilever-samples can provide a good basis for measurement comparison. However, when a particles-laden droplet on a solid surface is vaporized, a cluster-ring deposit is often yielded which makes particles counting difficult or impractical. Nevertheless, in this study, we present an approach, i.e., on-cantilever particles imprinting, which effectively defies such odds to sample and deposit countable single particles on a sensing surface. Initially, we designed and fabricated a triangular microcantilever sensor whose mass m(0), total beam-length L, and clamped-end beam-width w are equivalent to that of a rectangular/normal cantilever but with a higher resonant frequency (271 kHz), enhanced sensitivity (0.13 Hz/pg), and quality factor (~3000). To imprint particles on these cantilever sensors, various calibrated stainless steel dispensing tips were utilized to pioneer this study by dipping and retracting each tip from a small particle-laden droplet (resting on a hydrophobic n-type silicon substrate), followed by tip-sensor-contact (at a target point on the sensing area) to detach the solution (from the tip) and adsorb the particles, and ultimately determine the particles mass concentration. Upon imprinting/adsorbing the particles on the sensor, resonant frequency response measurements were made to determine the mass (or number of particles). A minimum detectable mass of ~0.05 pg was demonstrated. To further validate and compare such results, cantilever samples (containing adsorbed particles) were imaged by scanning electron microscopy (SEM) to determine the number of particles through counting (from which, the lowest count of about 11 magnetic polystyrene particles was obtained). The practicality of particle counting was essentially due to monolayer particle arrangement on the sensing surface. Moreover, in this work, the main measurement process influences are also explicitly examined. MDPI 2020-04-28 /pmc/articles/PMC7249213/ /pubmed/32354176 http://dx.doi.org/10.3390/s20092508 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nyang’au, Wilson Ombati
Setiono, Andi
Schmidt, Angelika
Bosse, Harald
Peiner, Erwin
Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title_full Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title_fullStr Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title_full_unstemmed Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title_short Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
title_sort sampling and mass detection of a countable number of microparticles using on-cantilever imprinting
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249213/
https://www.ncbi.nlm.nih.gov/pubmed/32354176
http://dx.doi.org/10.3390/s20092508
work_keys_str_mv AT nyangauwilsonombati samplingandmassdetectionofacountablenumberofmicroparticlesusingoncantileverimprinting
AT setionoandi samplingandmassdetectionofacountablenumberofmicroparticlesusingoncantileverimprinting
AT schmidtangelika samplingandmassdetectionofacountablenumberofmicroparticlesusingoncantileverimprinting
AT bosseharald samplingandmassdetectionofacountablenumberofmicroparticlesusingoncantileverimprinting
AT peinererwin samplingandmassdetectionofacountablenumberofmicroparticlesusingoncantileverimprinting