Cargando…

Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India

BACKGROUND: Accurate diagnosis of anemia by community workers using a point-of-care device is a challenge. The objective of the study was to establish the diagnostic accuracy of point-of-care devices for detecting anemia in community settings. METHODS: It was diagnostic accuracy study with cross-sec...

Descripción completa

Detalles Bibliográficos
Autores principales: Neogi, Sutapa Bandyopadhyay, Sharma, Jyoti, Pandey, Shivam, Zaidi, Nausheen, Bhattacharya, Maitreyee, Kar, Rakhee, Kar, Sitanshu Sekhar, Purohit, Abhishek, Bandyopadhyay, Sanjib, Saxena, Renu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249358/
https://www.ncbi.nlm.nih.gov/pubmed/32456639
http://dx.doi.org/10.1186/s12913-020-05329-9
_version_ 1783538575499853824
author Neogi, Sutapa Bandyopadhyay
Sharma, Jyoti
Pandey, Shivam
Zaidi, Nausheen
Bhattacharya, Maitreyee
Kar, Rakhee
Kar, Sitanshu Sekhar
Purohit, Abhishek
Bandyopadhyay, Sanjib
Saxena, Renu
author_facet Neogi, Sutapa Bandyopadhyay
Sharma, Jyoti
Pandey, Shivam
Zaidi, Nausheen
Bhattacharya, Maitreyee
Kar, Rakhee
Kar, Sitanshu Sekhar
Purohit, Abhishek
Bandyopadhyay, Sanjib
Saxena, Renu
author_sort Neogi, Sutapa Bandyopadhyay
collection PubMed
description BACKGROUND: Accurate diagnosis of anemia by community workers using a point-of-care device is a challenge. The objective of the study was to establish the diagnostic accuracy of point-of-care devices for detecting anemia in community settings. METHODS: It was diagnostic accuracy study with cross-sectional design on adult patients attending the outpatient department of rural/ urban health centres of Medical colleges from India. The index tests were HemoCue, TrueHb, Massimo’s device and spectroscopic device, compared against autoanalyzer (gold standard). Accuracy was expressed by sensitivity, specificity, likelihood ratios, predictive values, area under the curve (AUC) and levels of agreement. For the diagnostic accuracy component, 1407 participants were recruited with a minimum of 600 for each device. An additional 200 participants were considered to elucidate the performance of devices in different weather conditions. RESULTS: HemoCue and TrueHb performed better than Massimo and spectroscopic devices. Detection of anemia by technicians was similar between TrueHb and HemoCue (AUC 0.92 v/s 0.90, p > 0.05). Community workers performed better with Hemocue for detecting anemia compared to TrueHb (AUC 0.92 v/s 0.90, p < 0.05). For detection of severe anemia, accuracy of TrueHb was significantly better with technicians (AUC 0.91 v/s 0.70; p < 0.05) and community workers (AUC 0.91 v/s 0.73; p < 0.05). HemoCue showed a bias or mean difference (95%CI) of 0.47 g/dl (0.42, 0.52) for all values, and 0.92 g/dl (0.82, 1.03) for severe anemia. For TrueHb, it was − 0.28 g/dl (− 0.37, − 0.20) for all readings, and 0.06 g/dl (− 0.52, 0.63) for severe anemia. TrueHb appeared to be more consistent across different weather conditions, although it overestimated Hb in extreme cold weather conditions. CONCLUSION: For detection of anemia, True Hb and HemoCue were comparable. For severe anemia, True Hb seemed to be a better and feasible point-of-care device for detecting anemia in the community settings.
format Online
Article
Text
id pubmed-7249358
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72493582020-06-04 Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India Neogi, Sutapa Bandyopadhyay Sharma, Jyoti Pandey, Shivam Zaidi, Nausheen Bhattacharya, Maitreyee Kar, Rakhee Kar, Sitanshu Sekhar Purohit, Abhishek Bandyopadhyay, Sanjib Saxena, Renu BMC Health Serv Res Research Article BACKGROUND: Accurate diagnosis of anemia by community workers using a point-of-care device is a challenge. The objective of the study was to establish the diagnostic accuracy of point-of-care devices for detecting anemia in community settings. METHODS: It was diagnostic accuracy study with cross-sectional design on adult patients attending the outpatient department of rural/ urban health centres of Medical colleges from India. The index tests were HemoCue, TrueHb, Massimo’s device and spectroscopic device, compared against autoanalyzer (gold standard). Accuracy was expressed by sensitivity, specificity, likelihood ratios, predictive values, area under the curve (AUC) and levels of agreement. For the diagnostic accuracy component, 1407 participants were recruited with a minimum of 600 for each device. An additional 200 participants were considered to elucidate the performance of devices in different weather conditions. RESULTS: HemoCue and TrueHb performed better than Massimo and spectroscopic devices. Detection of anemia by technicians was similar between TrueHb and HemoCue (AUC 0.92 v/s 0.90, p > 0.05). Community workers performed better with Hemocue for detecting anemia compared to TrueHb (AUC 0.92 v/s 0.90, p < 0.05). For detection of severe anemia, accuracy of TrueHb was significantly better with technicians (AUC 0.91 v/s 0.70; p < 0.05) and community workers (AUC 0.91 v/s 0.73; p < 0.05). HemoCue showed a bias or mean difference (95%CI) of 0.47 g/dl (0.42, 0.52) for all values, and 0.92 g/dl (0.82, 1.03) for severe anemia. For TrueHb, it was − 0.28 g/dl (− 0.37, − 0.20) for all readings, and 0.06 g/dl (− 0.52, 0.63) for severe anemia. TrueHb appeared to be more consistent across different weather conditions, although it overestimated Hb in extreme cold weather conditions. CONCLUSION: For detection of anemia, True Hb and HemoCue were comparable. For severe anemia, True Hb seemed to be a better and feasible point-of-care device for detecting anemia in the community settings. BioMed Central 2020-05-26 /pmc/articles/PMC7249358/ /pubmed/32456639 http://dx.doi.org/10.1186/s12913-020-05329-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Neogi, Sutapa Bandyopadhyay
Sharma, Jyoti
Pandey, Shivam
Zaidi, Nausheen
Bhattacharya, Maitreyee
Kar, Rakhee
Kar, Sitanshu Sekhar
Purohit, Abhishek
Bandyopadhyay, Sanjib
Saxena, Renu
Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title_full Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title_fullStr Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title_full_unstemmed Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title_short Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India
title_sort diagnostic accuracy of point-of-care devices for detection of anemia in community settings in india
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249358/
https://www.ncbi.nlm.nih.gov/pubmed/32456639
http://dx.doi.org/10.1186/s12913-020-05329-9
work_keys_str_mv AT neogisutapabandyopadhyay diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT sharmajyoti diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT pandeyshivam diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT zaidinausheen diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT bhattacharyamaitreyee diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT karrakhee diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT karsitanshusekhar diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT purohitabhishek diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT bandyopadhyaysanjib diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia
AT saxenarenu diagnosticaccuracyofpointofcaredevicesfordetectionofanemiaincommunitysettingsinindia