Cargando…

Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †

The quality of processed workpieces is affected directly by the precision of the linear stage. Therefore, the linear displacement calibration of machine tools must be implemented before delivery and after employment for a period of time. How to perform a precise calibration with high inspection effi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shih, Yi-Chieh, Tung, Pi-Cheng, Wang, Yung-Cheng, Shyu, Lih-Horng, Manske, Eberhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249654/
https://www.ncbi.nlm.nih.gov/pubmed/32357499
http://dx.doi.org/10.3390/s20092462
_version_ 1783538630417973248
author Shih, Yi-Chieh
Tung, Pi-Cheng
Wang, Yung-Cheng
Shyu, Lih-Horng
Manske, Eberhard
author_facet Shih, Yi-Chieh
Tung, Pi-Cheng
Wang, Yung-Cheng
Shyu, Lih-Horng
Manske, Eberhard
author_sort Shih, Yi-Chieh
collection PubMed
description The quality of processed workpieces is affected directly by the precision of the linear stage. Therefore, the linear displacement calibration of machine tools must be implemented before delivery and after employment for a period of time. How to perform a precise calibration with high inspection efficiency is a critical issue in the precision mechanical engineering industry. In this study, the self-developed system integrated by the measurement module based on the common path Fabry–Pérot interferometer for linear displacement and the auto-alignment module for optical axes was proposed to realize the automatic linear displacement calibration of the linear stages. The measurement performance of the developed structure was verified experimentally. With the auto-alignment module, the cosine error was reduced to 0.36 nm and the entire procedure accomplished within 75 s without the limitation of the perceived resolution of the human eye, operational experience, and the risk of misalignment and broken cable. According to the comparison of experimental results for the linear displacement, the repeatability of the proposed measurement module was less than 0.171 μm. After the compensation procedure according to the linear displacement calibration, the systematic positional deviation, repeatability, and accuracy of the linear axis could be improved to 4 μm, 1 μm, and 5 μm respectively. Hence, the calibration efficiency can be improved by 80% with the proposed compact system, which is beneficial for the linear displacement calibration of machine tools in the precision mechanical engineering industry.
format Online
Article
Text
id pubmed-7249654
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72496542020-06-10 Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes † Shih, Yi-Chieh Tung, Pi-Cheng Wang, Yung-Cheng Shyu, Lih-Horng Manske, Eberhard Sensors (Basel) Article The quality of processed workpieces is affected directly by the precision of the linear stage. Therefore, the linear displacement calibration of machine tools must be implemented before delivery and after employment for a period of time. How to perform a precise calibration with high inspection efficiency is a critical issue in the precision mechanical engineering industry. In this study, the self-developed system integrated by the measurement module based on the common path Fabry–Pérot interferometer for linear displacement and the auto-alignment module for optical axes was proposed to realize the automatic linear displacement calibration of the linear stages. The measurement performance of the developed structure was verified experimentally. With the auto-alignment module, the cosine error was reduced to 0.36 nm and the entire procedure accomplished within 75 s without the limitation of the perceived resolution of the human eye, operational experience, and the risk of misalignment and broken cable. According to the comparison of experimental results for the linear displacement, the repeatability of the proposed measurement module was less than 0.171 μm. After the compensation procedure according to the linear displacement calibration, the systematic positional deviation, repeatability, and accuracy of the linear axis could be improved to 4 μm, 1 μm, and 5 μm respectively. Hence, the calibration efficiency can be improved by 80% with the proposed compact system, which is beneficial for the linear displacement calibration of machine tools in the precision mechanical engineering industry. MDPI 2020-04-26 /pmc/articles/PMC7249654/ /pubmed/32357499 http://dx.doi.org/10.3390/s20092462 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shih, Yi-Chieh
Tung, Pi-Cheng
Wang, Yung-Cheng
Shyu, Lih-Horng
Manske, Eberhard
Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title_full Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title_fullStr Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title_full_unstemmed Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title_short Linear Displacement Calibration System Integrated with a Novel Auto-Alignment Module for Optical Axes †
title_sort linear displacement calibration system integrated with a novel auto-alignment module for optical axes †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249654/
https://www.ncbi.nlm.nih.gov/pubmed/32357499
http://dx.doi.org/10.3390/s20092462
work_keys_str_mv AT shihyichieh lineardisplacementcalibrationsystemintegratedwithanovelautoalignmentmoduleforopticalaxes
AT tungpicheng lineardisplacementcalibrationsystemintegratedwithanovelautoalignmentmoduleforopticalaxes
AT wangyungcheng lineardisplacementcalibrationsystemintegratedwithanovelautoalignmentmoduleforopticalaxes
AT shyulihhorng lineardisplacementcalibrationsystemintegratedwithanovelautoalignmentmoduleforopticalaxes
AT manskeeberhard lineardisplacementcalibrationsystemintegratedwithanovelautoalignmentmoduleforopticalaxes