A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging

PURPOSE: To enable a preliminary assessment of the suitability of edge illumination (EI) x-ray phase contrast (XPC) micro x-ray computed tomography (micro-CT) to preclinical imaging. Specifically, to understand how different acquisition schemes and their combination with dedicated data processing af...

Descripción completa

Detalles Bibliográficos
Autores principales: Hagen, Charlotte K., Endrizzi, Marco, Towns, Rebecca, Meganck, Jeffrey A., Olivo, Alessandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7250795/
https://www.ncbi.nlm.nih.gov/pubmed/31250331
http://dx.doi.org/10.1007/s11307-019-01396-5
_version_ 1783538825308405760
author Hagen, Charlotte K.
Endrizzi, Marco
Towns, Rebecca
Meganck, Jeffrey A.
Olivo, Alessandro
author_facet Hagen, Charlotte K.
Endrizzi, Marco
Towns, Rebecca
Meganck, Jeffrey A.
Olivo, Alessandro
author_sort Hagen, Charlotte K.
collection PubMed
description PURPOSE: To enable a preliminary assessment of the suitability of edge illumination (EI) x-ray phase contrast (XPC) micro x-ray computed tomography (micro-CT) to preclinical imaging. Specifically, to understand how different acquisition schemes and their combination with dedicated data processing affect contrast-to-noise ratio (CNR) and spatial resolution, while providing control over scan time and radiation dose delivery. PROCEDURES: Deceased mice (n = 3) were scanned with an EI XPC micro-CT setup operated under different settings, leading to scan times between 18 h and 13 min. For the shortest scan, the entrance dose was measured with a calibrated PTW 23344 ion chamber. Different data processing methods were applied, retrieving either separate attenuation and phase images, or hybrid (combined attenuation and phase) images. A quantitative comparison was performed based on CNR and spatial resolution measurements for a soft tissue interface. RESULTS: All phase-based images have led to a higher CNR for the considered soft tissue interface than the attenuation image, independent of scan time. The best relative CNR (a sixfold increase) was observed in one of the hybrid images. Spatial resolution was found to be connected to scan time, with a resolution of approximately 20 μm and 60 μm achieved for the longest and shortest scans, respectively. An entrance dose of approximately 300 mGy was estimated for the scan performed within 13 min. CONCLUSIONS: Despite their preliminary nature, our results suggest that EI XPC bears potential for enhancing the utility of preclinical micro-CT, and, pending further research and development, could ultimately become a valuable technique in this field.
format Online
Article
Text
id pubmed-7250795
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-72507952020-06-03 A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging Hagen, Charlotte K. Endrizzi, Marco Towns, Rebecca Meganck, Jeffrey A. Olivo, Alessandro Mol Imaging Biol Research Article PURPOSE: To enable a preliminary assessment of the suitability of edge illumination (EI) x-ray phase contrast (XPC) micro x-ray computed tomography (micro-CT) to preclinical imaging. Specifically, to understand how different acquisition schemes and their combination with dedicated data processing affect contrast-to-noise ratio (CNR) and spatial resolution, while providing control over scan time and radiation dose delivery. PROCEDURES: Deceased mice (n = 3) were scanned with an EI XPC micro-CT setup operated under different settings, leading to scan times between 18 h and 13 min. For the shortest scan, the entrance dose was measured with a calibrated PTW 23344 ion chamber. Different data processing methods were applied, retrieving either separate attenuation and phase images, or hybrid (combined attenuation and phase) images. A quantitative comparison was performed based on CNR and spatial resolution measurements for a soft tissue interface. RESULTS: All phase-based images have led to a higher CNR for the considered soft tissue interface than the attenuation image, independent of scan time. The best relative CNR (a sixfold increase) was observed in one of the hybrid images. Spatial resolution was found to be connected to scan time, with a resolution of approximately 20 μm and 60 μm achieved for the longest and shortest scans, respectively. An entrance dose of approximately 300 mGy was estimated for the scan performed within 13 min. CONCLUSIONS: Despite their preliminary nature, our results suggest that EI XPC bears potential for enhancing the utility of preclinical micro-CT, and, pending further research and development, could ultimately become a valuable technique in this field. Springer International Publishing 2019-06-27 2020 /pmc/articles/PMC7250795/ /pubmed/31250331 http://dx.doi.org/10.1007/s11307-019-01396-5 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research Article
Hagen, Charlotte K.
Endrizzi, Marco
Towns, Rebecca
Meganck, Jeffrey A.
Olivo, Alessandro
A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title_full A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title_fullStr A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title_full_unstemmed A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title_short A Preliminary Investigation into the Use of Edge Illumination X-ray Phase Contrast Micro-CT for Preclinical Imaging
title_sort preliminary investigation into the use of edge illumination x-ray phase contrast micro-ct for preclinical imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7250795/
https://www.ncbi.nlm.nih.gov/pubmed/31250331
http://dx.doi.org/10.1007/s11307-019-01396-5
work_keys_str_mv AT hagencharlottek apreliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT endrizzimarco apreliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT townsrebecca apreliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT meganckjeffreya apreliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT olivoalessandro apreliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT hagencharlottek preliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT endrizzimarco preliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT townsrebecca preliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT meganckjeffreya preliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging
AT olivoalessandro preliminaryinvestigationintotheuseofedgeilluminationxrayphasecontrastmicroctforpreclinicalimaging