Cargando…
SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal
Atrial fibrillation is the most common arrhythmia and is associated with high morbidity and mortality from stroke, heart failure, myocardial infarction, and cerebral thrombosis. Effective and rapid detection of atrial fibrillation is critical to reducing morbidity and mortality in patients. Screenin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7251457/ https://www.ncbi.nlm.nih.gov/pubmed/32509259 http://dx.doi.org/10.1155/2020/7526825 |
_version_ | 1783538970525696000 |
---|---|
author | Zhang, Hongpo He, Renke Dai, Honghua Xu, Mingliang Wang, Zongmin |
author_facet | Zhang, Hongpo He, Renke Dai, Honghua Xu, Mingliang Wang, Zongmin |
author_sort | Zhang, Hongpo |
collection | PubMed |
description | Atrial fibrillation is the most common arrhythmia and is associated with high morbidity and mortality from stroke, heart failure, myocardial infarction, and cerebral thrombosis. Effective and rapid detection of atrial fibrillation is critical to reducing morbidity and mortality in patients. Screening atrial fibrillation quickly and efficiently remains a challenging task. In this paper, we propose SS-SWT and SI-CNN: an atrial fibrillation detection framework for the time-frequency ECG signal. First, specific-scale stationary wavelet transform (SS-SWT) is used to decompose a 5-s ECG signal into 8 scales. We select specific scales of coefficients as valid time-frequency features and abandon the other coefficients. The selected coefficients are fed to the scale-independent convolutional neural network (SI-CNN) as a two-dimensional (2D) matrix. In SI-CNN, a convolution kernel specifically for the time-frequency characteristics of ECG signals is designed. During the convolution process, the independence between each scale of coefficient is preserved, and the time domain and the frequency domain characteristics of the ECG signal are effectively extracted, and finally the atrial fibrillation signal is quickly and accurately identified. In this study, experiments are performed using the MIT-BIH AFDB data in 5-s data segments. We achieve 99.03% sensitivity, 99.35% specificity, and 99.23% overall accuracy. The SS-SWT and SI-CNN we propose simplify the feature extraction step, effectively extracts the features of ECG, and reduces the feature redundancy that may be caused by wavelet transform. The results shows that the method can effectively detect atrial fibrillation signals and has potential in clinical application. |
format | Online Article Text |
id | pubmed-7251457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-72514572020-06-06 SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal Zhang, Hongpo He, Renke Dai, Honghua Xu, Mingliang Wang, Zongmin J Healthc Eng Research Article Atrial fibrillation is the most common arrhythmia and is associated with high morbidity and mortality from stroke, heart failure, myocardial infarction, and cerebral thrombosis. Effective and rapid detection of atrial fibrillation is critical to reducing morbidity and mortality in patients. Screening atrial fibrillation quickly and efficiently remains a challenging task. In this paper, we propose SS-SWT and SI-CNN: an atrial fibrillation detection framework for the time-frequency ECG signal. First, specific-scale stationary wavelet transform (SS-SWT) is used to decompose a 5-s ECG signal into 8 scales. We select specific scales of coefficients as valid time-frequency features and abandon the other coefficients. The selected coefficients are fed to the scale-independent convolutional neural network (SI-CNN) as a two-dimensional (2D) matrix. In SI-CNN, a convolution kernel specifically for the time-frequency characteristics of ECG signals is designed. During the convolution process, the independence between each scale of coefficient is preserved, and the time domain and the frequency domain characteristics of the ECG signal are effectively extracted, and finally the atrial fibrillation signal is quickly and accurately identified. In this study, experiments are performed using the MIT-BIH AFDB data in 5-s data segments. We achieve 99.03% sensitivity, 99.35% specificity, and 99.23% overall accuracy. The SS-SWT and SI-CNN we propose simplify the feature extraction step, effectively extracts the features of ECG, and reduces the feature redundancy that may be caused by wavelet transform. The results shows that the method can effectively detect atrial fibrillation signals and has potential in clinical application. Hindawi 2020-05-18 /pmc/articles/PMC7251457/ /pubmed/32509259 http://dx.doi.org/10.1155/2020/7526825 Text en Copyright © 2020 Hongpo Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Hongpo He, Renke Dai, Honghua Xu, Mingliang Wang, Zongmin SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title | SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title_full | SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title_fullStr | SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title_full_unstemmed | SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title_short | SS-SWT and SI-CNN: An Atrial Fibrillation Detection Framework for Time-Frequency ECG Signal |
title_sort | ss-swt and si-cnn: an atrial fibrillation detection framework for time-frequency ecg signal |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7251457/ https://www.ncbi.nlm.nih.gov/pubmed/32509259 http://dx.doi.org/10.1155/2020/7526825 |
work_keys_str_mv | AT zhanghongpo ssswtandsicnnanatrialfibrillationdetectionframeworkfortimefrequencyecgsignal AT herenke ssswtandsicnnanatrialfibrillationdetectionframeworkfortimefrequencyecgsignal AT daihonghua ssswtandsicnnanatrialfibrillationdetectionframeworkfortimefrequencyecgsignal AT xumingliang ssswtandsicnnanatrialfibrillationdetectionframeworkfortimefrequencyecgsignal AT wangzongmin ssswtandsicnnanatrialfibrillationdetectionframeworkfortimefrequencyecgsignal |