Cargando…

Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China

OBJECTIVE: Sino-implant (II) is a contraceptive implant approved for 4 years of use in China. We evaluated the contraceptive efficacy during the third, fourth and fifth year, and assessed additional pharmacokinetics (PK), safety, and acceptability endpoints. STUDY DESIGN: We enrolled a cohort of 255...

Descripción completa

Detalles Bibliográficos
Autores principales: Che, Y, Taylor, D, Luo, D, Maldonado, LY, Wang, M, Wevill, S, Vahdat, H, Han, X, Halpern, V, Dorflinger, L, Steiner, MJ
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252427/
https://www.ncbi.nlm.nih.gov/pubmed/32494773
http://dx.doi.org/10.1016/j.conx.2019.100008
_version_ 1783539159957241856
author Che, Y
Taylor, D
Luo, D
Maldonado, LY
Wang, M
Wevill, S
Vahdat, H
Han, X
Halpern, V
Dorflinger, L
Steiner, MJ
author_facet Che, Y
Taylor, D
Luo, D
Maldonado, LY
Wang, M
Wevill, S
Vahdat, H
Han, X
Halpern, V
Dorflinger, L
Steiner, MJ
author_sort Che, Y
collection PubMed
description OBJECTIVE: Sino-implant (II) is a contraceptive implant approved for 4 years of use in China. We evaluated the contraceptive efficacy during the third, fourth and fifth year, and assessed additional pharmacokinetics (PK), safety, and acceptability endpoints. STUDY DESIGN: We enrolled a cohort of 255 current Sino-Implant (II) users entering their third year and a second cohort of 243 users entering their fourth year. We followed these two cohorts for 12 and 24 months, respectively. To characterize PK endpoints (i.e. levonorgestrel (LNG), sex hormone binding globulin and free LNG index) over 5 years, we collected blood samples in a subset of 50 participants we followed during the third, fourth and fifth year. We also enrolled small cohorts (n = 20) of Sino-implant (II) users entering their sixth month and second year and followed them each for up to 6 months. Our primary efficacy measures were the pregnancy Pearl Indices during Year 3 and 4. Secondary objectives included assessments of PK, safety, acceptability and efficacy in the fifth year. RESULTS: We recorded four pregnancies, with a higher pregnancy rate during Year 3 [1.34 (95% CI: 0.28–3.93)] than Year 4 [0.44 (95% CI: 0.01–2.47)] or Year 5 [0.00 (95% CI: 0.00–2.02)]. The overall pregnancy rate for the third, fourth and fifth years of product use was 0.63 per 100 WY; 95% CI: (0.17–1.62). Mean LNG concentrations remained well above 200 pg/mL (Year 3 = 280.9; Year 4 = 233.6; Year 5 = 270.6). Most participants (93.7%) described their bleeding pattern as acceptable. CONCLUSION: Sino-implant (II) is a highly effective contraceptive method in this population of Chinese women over 5 years. IMPLICATIONS: Sino-implant (II) is a highly effective contraceptive method with an estimated Pearl Index of less than 1% over the third, fourth and fifth years of use in a population of Chinese women of reproductive age.
format Online
Article
Text
id pubmed-7252427
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72524272020-06-01 Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China Che, Y Taylor, D Luo, D Maldonado, LY Wang, M Wevill, S Vahdat, H Han, X Halpern, V Dorflinger, L Steiner, MJ Contracept X Article OBJECTIVE: Sino-implant (II) is a contraceptive implant approved for 4 years of use in China. We evaluated the contraceptive efficacy during the third, fourth and fifth year, and assessed additional pharmacokinetics (PK), safety, and acceptability endpoints. STUDY DESIGN: We enrolled a cohort of 255 current Sino-Implant (II) users entering their third year and a second cohort of 243 users entering their fourth year. We followed these two cohorts for 12 and 24 months, respectively. To characterize PK endpoints (i.e. levonorgestrel (LNG), sex hormone binding globulin and free LNG index) over 5 years, we collected blood samples in a subset of 50 participants we followed during the third, fourth and fifth year. We also enrolled small cohorts (n = 20) of Sino-implant (II) users entering their sixth month and second year and followed them each for up to 6 months. Our primary efficacy measures were the pregnancy Pearl Indices during Year 3 and 4. Secondary objectives included assessments of PK, safety, acceptability and efficacy in the fifth year. RESULTS: We recorded four pregnancies, with a higher pregnancy rate during Year 3 [1.34 (95% CI: 0.28–3.93)] than Year 4 [0.44 (95% CI: 0.01–2.47)] or Year 5 [0.00 (95% CI: 0.00–2.02)]. The overall pregnancy rate for the third, fourth and fifth years of product use was 0.63 per 100 WY; 95% CI: (0.17–1.62). Mean LNG concentrations remained well above 200 pg/mL (Year 3 = 280.9; Year 4 = 233.6; Year 5 = 270.6). Most participants (93.7%) described their bleeding pattern as acceptable. CONCLUSION: Sino-implant (II) is a highly effective contraceptive method in this population of Chinese women over 5 years. IMPLICATIONS: Sino-implant (II) is a highly effective contraceptive method with an estimated Pearl Index of less than 1% over the third, fourth and fifth years of use in a population of Chinese women of reproductive age. Elsevier 2019-06-20 /pmc/articles/PMC7252427/ /pubmed/32494773 http://dx.doi.org/10.1016/j.conx.2019.100008 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Che, Y
Taylor, D
Luo, D
Maldonado, LY
Wang, M
Wevill, S
Vahdat, H
Han, X
Halpern, V
Dorflinger, L
Steiner, MJ
Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title_full Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title_fullStr Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title_full_unstemmed Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title_short Cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in China
title_sort cohort study to evaluate efficacy, safety and acceptability of a two-rod contraceptive implant during third, fourth and fifth year of product use in china
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252427/
https://www.ncbi.nlm.nih.gov/pubmed/32494773
http://dx.doi.org/10.1016/j.conx.2019.100008
work_keys_str_mv AT chey cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT taylord cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT luod cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT maldonadoly cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT wangm cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT wevills cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT vahdath cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT hanx cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT halpernv cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT dorflingerl cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina
AT steinermj cohortstudytoevaluateefficacysafetyandacceptabilityofatworodcontraceptiveimplantduringthirdfourthandfifthyearofproductuseinchina