Cargando…

Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor

The association between ventricular arrhythmia (VA) burden or defibrillator therapy and pulmonary artery pressure (PAP) has not been characterized in an ambulatory setting; thus, we sought in the present research to determine the relationship between ambulatory PAP and VA burden. A retrospective coh...

Descripción completa

Detalles Bibliográficos
Autores principales: Doshi, Rahul N., Carlson, Steven, Agarwal, Rahul, Bharmi, Rupinder, Adamson, Philip B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252698/
https://www.ncbi.nlm.nih.gov/pubmed/32477750
http://dx.doi.org/10.19102/icrm.2019.100903
_version_ 1783539199310299136
author Doshi, Rahul N.
Carlson, Steven
Agarwal, Rahul
Bharmi, Rupinder
Adamson, Philip B.
author_facet Doshi, Rahul N.
Carlson, Steven
Agarwal, Rahul
Bharmi, Rupinder
Adamson, Philip B.
author_sort Doshi, Rahul N.
collection PubMed
description The association between ventricular arrhythmia (VA) burden or defibrillator therapy and pulmonary artery pressure (PAP) has not been characterized in an ambulatory setting; thus, we sought in the present research to determine the relationship between ambulatory PAP and VA burden. A retrospective cohort study involving patients with an implantable cardiac defibrillator and CardioMEMS™ PAP sensor (Abbott Laboratories, Chicago, IL, USA) both transmitting remotely into the Merlin.net™ patient care network (Abbott Laboratories, Chicago, IL, USA) was conducted. VA and therapy burden in the six months following sensor implant were stratified by the baseline mean PAP. Patients with PAPs of 25 mmHg to 35 mmHg and those with PAPs of 35 mmHg or more were compared with individuals with PAPs of less than 25 mmHg. The change in VA burden was reported using the averaged mean PAP reduction during the first three months. A total of 162 patients aged 69.4 years ± 10.9 years were included (74% male) with a baseline mean PAP of 36.2 mmHg ± 10.4 mmHg. Twenty patients with a baseline mean PAP of less than 25 mmHg had no VAs over six months. For 61 patients with a baseline mean PAP of between 25 mmHg and 35 mmHg, the annualized number of days with ventricular tachycardia (VT)/ventricular fibrillation (VF) was 1.65/patient-year (p < 0.001), with 8% of patients having VT/VF events. For 81 patients with a baseline mean PAP of 35 mmHg or more, 19% of patients had a VT/VF event and an annualized number of days with VT/VF events of 1.45/patient-year (p < 0.001). When analyzing the treatment effect, a reduction of 3 mmHg or more in mean PAP over three months reduced arrhythmia burden over the next three months as compared with in patients without such an improvement. In conclusion, it is indicated that VAs are associated with high PAPs, and a reduction in PAP may lead to a reduction in VAs in real-world ambulatory patients.
format Online
Article
Text
id pubmed-7252698
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-72526982020-05-28 Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor Doshi, Rahul N. Carlson, Steven Agarwal, Rahul Bharmi, Rupinder Adamson, Philip B. J Innov Card Rhythm Manag Original Research The association between ventricular arrhythmia (VA) burden or defibrillator therapy and pulmonary artery pressure (PAP) has not been characterized in an ambulatory setting; thus, we sought in the present research to determine the relationship between ambulatory PAP and VA burden. A retrospective cohort study involving patients with an implantable cardiac defibrillator and CardioMEMS™ PAP sensor (Abbott Laboratories, Chicago, IL, USA) both transmitting remotely into the Merlin.net™ patient care network (Abbott Laboratories, Chicago, IL, USA) was conducted. VA and therapy burden in the six months following sensor implant were stratified by the baseline mean PAP. Patients with PAPs of 25 mmHg to 35 mmHg and those with PAPs of 35 mmHg or more were compared with individuals with PAPs of less than 25 mmHg. The change in VA burden was reported using the averaged mean PAP reduction during the first three months. A total of 162 patients aged 69.4 years ± 10.9 years were included (74% male) with a baseline mean PAP of 36.2 mmHg ± 10.4 mmHg. Twenty patients with a baseline mean PAP of less than 25 mmHg had no VAs over six months. For 61 patients with a baseline mean PAP of between 25 mmHg and 35 mmHg, the annualized number of days with ventricular tachycardia (VT)/ventricular fibrillation (VF) was 1.65/patient-year (p < 0.001), with 8% of patients having VT/VF events. For 81 patients with a baseline mean PAP of 35 mmHg or more, 19% of patients had a VT/VF event and an annualized number of days with VT/VF events of 1.45/patient-year (p < 0.001). When analyzing the treatment effect, a reduction of 3 mmHg or more in mean PAP over three months reduced arrhythmia burden over the next three months as compared with in patients without such an improvement. In conclusion, it is indicated that VAs are associated with high PAPs, and a reduction in PAP may lead to a reduction in VAs in real-world ambulatory patients. MediaSphere Medical 2019-09-15 /pmc/articles/PMC7252698/ /pubmed/32477750 http://dx.doi.org/10.19102/icrm.2019.100903 Text en Copyright: © 2019 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Doshi, Rahul N.
Carlson, Steven
Agarwal, Rahul
Bharmi, Rupinder
Adamson, Philip B.
Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title_full Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title_fullStr Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title_full_unstemmed Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title_short Association between Arrhythmia and Pulmonary Artery Pressure in Heart Failure Patients Implanted with a Cardiac Defibrillator and Ambulatory Pulmonary Artery Pressure Sensor
title_sort association between arrhythmia and pulmonary artery pressure in heart failure patients implanted with a cardiac defibrillator and ambulatory pulmonary artery pressure sensor
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252698/
https://www.ncbi.nlm.nih.gov/pubmed/32477750
http://dx.doi.org/10.19102/icrm.2019.100903
work_keys_str_mv AT doshirahuln associationbetweenarrhythmiaandpulmonaryarterypressureinheartfailurepatientsimplantedwithacardiacdefibrillatorandambulatorypulmonaryarterypressuresensor
AT carlsonsteven associationbetweenarrhythmiaandpulmonaryarterypressureinheartfailurepatientsimplantedwithacardiacdefibrillatorandambulatorypulmonaryarterypressuresensor
AT agarwalrahul associationbetweenarrhythmiaandpulmonaryarterypressureinheartfailurepatientsimplantedwithacardiacdefibrillatorandambulatorypulmonaryarterypressuresensor
AT bharmirupinder associationbetweenarrhythmiaandpulmonaryarterypressureinheartfailurepatientsimplantedwithacardiacdefibrillatorandambulatorypulmonaryarterypressuresensor
AT adamsonphilipb associationbetweenarrhythmiaandpulmonaryarterypressureinheartfailurepatientsimplantedwithacardiacdefibrillatorandambulatorypulmonaryarterypressuresensor