Cargando…

Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data

Ventricular arrhythmias are common in the early period after myocardial infarction (MI), with the highest risk occurring in the immediate postinfarct window. The wearable cardioverter-defibrillator (WCD) has been proven to have efficacy in treating sudden cardiac arrest in patients soon after MI. Ho...

Descripción completa

Detalles Bibliográficos
Autores principales: Clark, Mary Ann, Szymkiewicz, Steven J., Volosin, Kent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252700/
https://www.ncbi.nlm.nih.gov/pubmed/32477706
http://dx.doi.org/10.19102/icrm.2019.101007
_version_ 1783539199540985856
author Clark, Mary Ann
Szymkiewicz, Steven J.
Volosin, Kent
author_facet Clark, Mary Ann
Szymkiewicz, Steven J.
Volosin, Kent
author_sort Clark, Mary Ann
collection PubMed
description Ventricular arrhythmias are common in the early period after myocardial infarction (MI), with the highest risk occurring in the immediate postinfarct window. The wearable cardioverter-defibrillator (WCD) has been proven to have efficacy in treating sudden cardiac arrest in patients soon after MI. However, data concerning clinical and health economic outcomes of WCD usage among Medicare patients have not been evaluated. The aim of this study was therefore to investigate the clinical and health economic impacts of WCD use among Medicare patients hospitalized for MI. A 5% sample of Medicare’s Standard Analytical Files (2010–2012) was used to identify patients. Beneficiaries with an acute inpatient admission for acute MI were stratified by WCD presence and absence, respectively. Baseline clinical history, all-cause mortality, and the total cost of health-care expenditures over one year were collected. In total, 16,935 patients were included in the final analysis; of these, 89 were placed in the WCD group and 16,846 were placed in the non-WCD group. Overall, WCD patients were younger (70 versus 74 years of age; p < 0.001), more likely to be male (74.2% versus 57.4%; p = 0.002), and more likely to have congestive heart failure and/or ventricular arrhythmias prior to the indexed acute MI. At 30 days, the mortality rate in the WCD group (not reported due to volume < 11 Medicare beneficiaries) was lower in comparison with the non-WCD group (10.4%; p = 0.18). At one year, the adjusted mortality rates were 11.5% for the WCD group and 19.8% for the non-WCD group (hazard ratio: 0.46; p = 0.017). For the WCD group, the one-year incremental cost-effectiveness ratio was $12,373 per life-year gained. Among Medicare beneficiaries, WCD use after an acute MI was associated with better 30-day and one-year survival. Thus, our findings indicate that WCD use was cost-effective in the present sample of Medicare patients.
format Online
Article
Text
id pubmed-7252700
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-72527002020-05-28 Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data Clark, Mary Ann Szymkiewicz, Steven J. Volosin, Kent J Innov Card Rhythm Manag Original Research Ventricular arrhythmias are common in the early period after myocardial infarction (MI), with the highest risk occurring in the immediate postinfarct window. The wearable cardioverter-defibrillator (WCD) has been proven to have efficacy in treating sudden cardiac arrest in patients soon after MI. However, data concerning clinical and health economic outcomes of WCD usage among Medicare patients have not been evaluated. The aim of this study was therefore to investigate the clinical and health economic impacts of WCD use among Medicare patients hospitalized for MI. A 5% sample of Medicare’s Standard Analytical Files (2010–2012) was used to identify patients. Beneficiaries with an acute inpatient admission for acute MI were stratified by WCD presence and absence, respectively. Baseline clinical history, all-cause mortality, and the total cost of health-care expenditures over one year were collected. In total, 16,935 patients were included in the final analysis; of these, 89 were placed in the WCD group and 16,846 were placed in the non-WCD group. Overall, WCD patients were younger (70 versus 74 years of age; p < 0.001), more likely to be male (74.2% versus 57.4%; p = 0.002), and more likely to have congestive heart failure and/or ventricular arrhythmias prior to the indexed acute MI. At 30 days, the mortality rate in the WCD group (not reported due to volume < 11 Medicare beneficiaries) was lower in comparison with the non-WCD group (10.4%; p = 0.18). At one year, the adjusted mortality rates were 11.5% for the WCD group and 19.8% for the non-WCD group (hazard ratio: 0.46; p = 0.017). For the WCD group, the one-year incremental cost-effectiveness ratio was $12,373 per life-year gained. Among Medicare beneficiaries, WCD use after an acute MI was associated with better 30-day and one-year survival. Thus, our findings indicate that WCD use was cost-effective in the present sample of Medicare patients. MediaSphere Medical 2019-10-15 /pmc/articles/PMC7252700/ /pubmed/32477706 http://dx.doi.org/10.19102/icrm.2019.101007 Text en Copyright: © 2019 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Clark, Mary Ann
Szymkiewicz, Steven J.
Volosin, Kent
Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title_full Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title_fullStr Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title_full_unstemmed Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title_short Mortality and Costs Associated with Wearable Cardioverter-defibrillators after Acute Myocardial Infarction: A Retrospective Cohort Analysis of Medicare Claims Data
title_sort mortality and costs associated with wearable cardioverter-defibrillators after acute myocardial infarction: a retrospective cohort analysis of medicare claims data
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252700/
https://www.ncbi.nlm.nih.gov/pubmed/32477706
http://dx.doi.org/10.19102/icrm.2019.101007
work_keys_str_mv AT clarkmaryann mortalityandcostsassociatedwithwearablecardioverterdefibrillatorsafteracutemyocardialinfarctionaretrospectivecohortanalysisofmedicareclaimsdata
AT szymkiewiczstevenj mortalityandcostsassociatedwithwearablecardioverterdefibrillatorsafteracutemyocardialinfarctionaretrospectivecohortanalysisofmedicareclaimsdata
AT volosinkent mortalityandcostsassociatedwithwearablecardioverterdefibrillatorsafteracutemyocardialinfarctionaretrospectivecohortanalysisofmedicareclaimsdata