P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients

Implantable loop recorders are commonly used to sense arrhythmias. The purpose of this study is to assess the P- and R-wave amplitudes at implantation (I) and follow-up (F) following insertion of the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) in an institutional review boar...

Descripción completa

Detalles Bibliográficos
Autores principales: D’Souza, Roshan, Thomas, Elizabeth, Macicek, Scott, Aziz, Peter, Shivapour, Jill K., Snyder, Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252757/
https://www.ncbi.nlm.nih.gov/pubmed/32477753
http://dx.doi.org/10.19102/icrm.2017.080102
_version_ 1783539212791840768
author D’Souza, Roshan
Thomas, Elizabeth
Macicek, Scott
Aziz, Peter
Shivapour, Jill K.
Snyder, Christopher
author_facet D’Souza, Roshan
Thomas, Elizabeth
Macicek, Scott
Aziz, Peter
Shivapour, Jill K.
Snyder, Christopher
author_sort D’Souza, Roshan
collection PubMed
description Implantable loop recorders are commonly used to sense arrhythmias. The purpose of this study is to assess the P- and R-wave amplitudes at implantation (I) and follow-up (F) following insertion of the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) in an institutional review board-approved, multicenter study performed on pediatric patients younger than 18 years old. Collected data included demographics, presence of congenital heart disease (CHD), P- and R-wave-sensed amplitude at I and F, and the method of implant (i.e. mapping or standard.) P waves were manually measured and R-wave sensing was recorded by the device. A total of 87 patients had a Reveal LINQ™ (Medtronic, Minneapolis, MN) device implanted; the mean patient age was 11.8 years (0.5 years to 18 years) with 48% of patients being female and 19% of patients having CHD; mapping was used in 43% of patients. The Reveal LINQ™ (Medtronic, Minneapolis, MN) experienced no change in average sensed R-wave amplitude at either I or F (1.28 mV vs 1.26 mV, p = NS). There was no difference in sensed R-wave amplitude noted with or without mapping used at I (1.29 mV vs 1.26 mV, p = NS) or F (1.48 mV vs 1.18 mV, p = NS). Additionally, no difference could be found in R-wave sensing of patients with CHD or without CHD at I (1.26 mV vs 1.4 mV, p = NS) or F (1.32 mV vs 1.32 mV, p = NS). R-wave sensing trended towards being inversely proportional to patient body surface area (BSA) (p = NS). P waves were detected on 48% of tracings in all patients at I and/or F, irrespective of whether the Reveal LINQ™ (Medtronic, Minneapolis, MN) device was placed with mapping. The R wave was (0.37–3.5 mV) at I and (0.3–3 mV) (p = NS) at F when P waves were detected. From these results, it can be said that the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) has an excellent ability to sense R-wave amplitude in pediatric patients. No significant difference in the sensing ability of the device could be identified with respect to the presence of CHD, use of mapping or BSA. P waves tended to be identified when there was a higher baseline R-wave amplitude.
format Online
Article
Text
id pubmed-7252757
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-72527572020-05-28 P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients D’Souza, Roshan Thomas, Elizabeth Macicek, Scott Aziz, Peter Shivapour, Jill K. Snyder, Christopher J Innov Card Rhythm Manag Original Research Implantable loop recorders are commonly used to sense arrhythmias. The purpose of this study is to assess the P- and R-wave amplitudes at implantation (I) and follow-up (F) following insertion of the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) in an institutional review board-approved, multicenter study performed on pediatric patients younger than 18 years old. Collected data included demographics, presence of congenital heart disease (CHD), P- and R-wave-sensed amplitude at I and F, and the method of implant (i.e. mapping or standard.) P waves were manually measured and R-wave sensing was recorded by the device. A total of 87 patients had a Reveal LINQ™ (Medtronic, Minneapolis, MN) device implanted; the mean patient age was 11.8 years (0.5 years to 18 years) with 48% of patients being female and 19% of patients having CHD; mapping was used in 43% of patients. The Reveal LINQ™ (Medtronic, Minneapolis, MN) experienced no change in average sensed R-wave amplitude at either I or F (1.28 mV vs 1.26 mV, p = NS). There was no difference in sensed R-wave amplitude noted with or without mapping used at I (1.29 mV vs 1.26 mV, p = NS) or F (1.48 mV vs 1.18 mV, p = NS). Additionally, no difference could be found in R-wave sensing of patients with CHD or without CHD at I (1.26 mV vs 1.4 mV, p = NS) or F (1.32 mV vs 1.32 mV, p = NS). R-wave sensing trended towards being inversely proportional to patient body surface area (BSA) (p = NS). P waves were detected on 48% of tracings in all patients at I and/or F, irrespective of whether the Reveal LINQ™ (Medtronic, Minneapolis, MN) device was placed with mapping. The R wave was (0.37–3.5 mV) at I and (0.3–3 mV) (p = NS) at F when P waves were detected. From these results, it can be said that the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) has an excellent ability to sense R-wave amplitude in pediatric patients. No significant difference in the sensing ability of the device could be identified with respect to the presence of CHD, use of mapping or BSA. P waves tended to be identified when there was a higher baseline R-wave amplitude. MediaSphere Medical 2017-01-15 /pmc/articles/PMC7252757/ /pubmed/32477753 http://dx.doi.org/10.19102/icrm.2017.080102 Text en Copyright: © 2017 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
D’Souza, Roshan
Thomas, Elizabeth
Macicek, Scott
Aziz, Peter
Shivapour, Jill K.
Snyder, Christopher
P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title_full P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title_fullStr P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title_full_unstemmed P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title_short P- and R-wave Amplitude Sensed by Reveal LINQ™ Loop Recorder in Pediatric Patients
title_sort p- and r-wave amplitude sensed by reveal linq™ loop recorder in pediatric patients
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252757/
https://www.ncbi.nlm.nih.gov/pubmed/32477753
http://dx.doi.org/10.19102/icrm.2017.080102
work_keys_str_mv AT dsouzaroshan pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients
AT thomaselizabeth pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients
AT macicekscott pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients
AT azizpeter pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients
AT shivapourjillk pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients
AT snyderchristopher pandrwaveamplitudesensedbyreveallinqlooprecorderinpediatricpatients