Cargando…

Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon

Intact retrograde ventriculoatrial (VA) conduction in the presence of complete atrioventricular (AV) heart block has been well-documented in the past. We sought to describe the prevalence and clinical significance of intact VA conduction accompanied by complete antegrade AV block in patients with im...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhir, Sumer, Gould, Grant E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252768/
https://www.ncbi.nlm.nih.gov/pubmed/32477725
http://dx.doi.org/10.19102/icrm.2019.100408
_version_ 1783539215403843584
author Dhir, Sumer
Gould, Grant E.
author_facet Dhir, Sumer
Gould, Grant E.
author_sort Dhir, Sumer
collection PubMed
description Intact retrograde ventriculoatrial (VA) conduction in the presence of complete atrioventricular (AV) heart block has been well-documented in the past. We sought to describe the prevalence and clinical significance of intact VA conduction accompanied by complete antegrade AV block in patients with implanted cardiac rhythm management (CRM) devices. During routine follow-up of CRM devices in our device clinic, 42 patients were found to be in a state of complete heart block. All patients presented in sinus rhythm. The patients’ underlying rhythms were tested with the inhibition of pacing and documented AV dissociation. Subsequently, retrograde VA conduction was tested with ventricular pacing. In the 42 patients with complete heart block as the underlying rhythm, five patients demonstrated retrograde VA conduction. In conclusion, the prevalence of intact of VA conduction was 11.9% in our study. The implications of this phenomenon can have noteworthy clinical significance. The occurrence of pacemaker-mediated tachycardia and repetitive nonreentrant VA synchrony are discussed herein. All patients, even those with a device indication of complete heart block, should be tested for retrograde conduction at implantation and during routine follow-up.
format Online
Article
Text
id pubmed-7252768
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-72527682020-05-28 Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon Dhir, Sumer Gould, Grant E. J Innov Card Rhythm Manag Original Research Intact retrograde ventriculoatrial (VA) conduction in the presence of complete atrioventricular (AV) heart block has been well-documented in the past. We sought to describe the prevalence and clinical significance of intact VA conduction accompanied by complete antegrade AV block in patients with implanted cardiac rhythm management (CRM) devices. During routine follow-up of CRM devices in our device clinic, 42 patients were found to be in a state of complete heart block. All patients presented in sinus rhythm. The patients’ underlying rhythms were tested with the inhibition of pacing and documented AV dissociation. Subsequently, retrograde VA conduction was tested with ventricular pacing. In the 42 patients with complete heart block as the underlying rhythm, five patients demonstrated retrograde VA conduction. In conclusion, the prevalence of intact of VA conduction was 11.9% in our study. The implications of this phenomenon can have noteworthy clinical significance. The occurrence of pacemaker-mediated tachycardia and repetitive nonreentrant VA synchrony are discussed herein. All patients, even those with a device indication of complete heart block, should be tested for retrograde conduction at implantation and during routine follow-up. MediaSphere Medical 2019-04-15 /pmc/articles/PMC7252768/ /pubmed/32477725 http://dx.doi.org/10.19102/icrm.2019.100408 Text en Copyright: © 2019 Innovations in Cardiac Rhythm Management http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Dhir, Sumer
Gould, Grant E.
Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title_full Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title_fullStr Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title_full_unstemmed Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title_short Complete Atrioventricular Block with Intact Retrograde Conduction in Cardiac Rhythm Management Devices: Implications of the Phenomenon
title_sort complete atrioventricular block with intact retrograde conduction in cardiac rhythm management devices: implications of the phenomenon
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252768/
https://www.ncbi.nlm.nih.gov/pubmed/32477725
http://dx.doi.org/10.19102/icrm.2019.100408
work_keys_str_mv AT dhirsumer completeatrioventricularblockwithintactretrogradeconductionincardiacrhythmmanagementdevicesimplicationsofthephenomenon
AT gouldgrante completeatrioventricularblockwithintactretrogradeconductionincardiacrhythmmanagementdevicesimplicationsofthephenomenon