Cargando…
Selective His-bundle Pacing May Preserve Intrinsic Repolarization as Well as Depolarization
A 79-year-old man with chronic atrial fibrillation underwent single-chamber His-bundle pacemaker implantation. The post-implant electrocardiogram (ECG) demonstrated selective His-bundle capture, with a narrow paced QRS and repolarization pattern similar to that of the baseline ECG. Furthermore, repo...
Autores principales: | Chinitz, Jason S., Scheinbach, Alan, Ong, Lawrence, Stephenson, Kent |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MediaSphere Medical
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7252784/ https://www.ncbi.nlm.nih.gov/pubmed/32477771 http://dx.doi.org/10.19102/icrm.2017.080301 |
Ejemplares similares
-
Commentary: Selective His-Bundle Pacing May Preserve Intrinsic Repolarization as Well as Depolarization
por: Tondo, Claudio
Publicado: (2017) -
His-bundle Pacing to Left Bundle Branch Pacing: Evolution of His-Purkinje Conduction System Pacing
por: Vijayaraman, Pugazhendhi
Publicado: (2019) -
Depolarization and repolarization dynamics after His‐bundle pacing: Comparison with right ventricular pacing and native ventricular conduction
por: Yanagisawa, Satoshi, et al.
Publicado: (2022) -
Depolarization-repolarization synchrony after right ventricular and left bundle branch area pacing
por: Sales Belles, C, et al.
Publicado: (2023) -
Direct His-bundle Pacing in a Patient with a Persistent Left Superior Vena Cava
por: Deshmukh, Amrish, et al.
Publicado: (2019)