Cargando…
Corrosion Behavior of Surface-Treated Metallic Implant Materials
Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7254368/ https://www.ncbi.nlm.nih.gov/pubmed/32344822 http://dx.doi.org/10.3390/ma13092011 |
_version_ | 1783539528852570112 |
---|---|
author | Bormann, Therese Mai, Phuong Thao Gibmeier, Jens Sonntag, Robert Müller, Ulrike Kretzer, J. Philippe |
author_facet | Bormann, Therese Mai, Phuong Thao Gibmeier, Jens Sonntag, Robert Müller, Ulrike Kretzer, J. Philippe |
author_sort | Bormann, Therese |
collection | PubMed |
description | Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments. |
format | Online Article Text |
id | pubmed-7254368 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72543682020-06-10 Corrosion Behavior of Surface-Treated Metallic Implant Materials Bormann, Therese Mai, Phuong Thao Gibmeier, Jens Sonntag, Robert Müller, Ulrike Kretzer, J. Philippe Materials (Basel) Article Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments. MDPI 2020-04-25 /pmc/articles/PMC7254368/ /pubmed/32344822 http://dx.doi.org/10.3390/ma13092011 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bormann, Therese Mai, Phuong Thao Gibmeier, Jens Sonntag, Robert Müller, Ulrike Kretzer, J. Philippe Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title | Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title_full | Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title_fullStr | Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title_full_unstemmed | Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title_short | Corrosion Behavior of Surface-Treated Metallic Implant Materials |
title_sort | corrosion behavior of surface-treated metallic implant materials |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7254368/ https://www.ncbi.nlm.nih.gov/pubmed/32344822 http://dx.doi.org/10.3390/ma13092011 |
work_keys_str_mv | AT bormanntherese corrosionbehaviorofsurfacetreatedmetallicimplantmaterials AT maiphuongthao corrosionbehaviorofsurfacetreatedmetallicimplantmaterials AT gibmeierjens corrosionbehaviorofsurfacetreatedmetallicimplantmaterials AT sonntagrobert corrosionbehaviorofsurfacetreatedmetallicimplantmaterials AT mullerulrike corrosionbehaviorofsurfacetreatedmetallicimplantmaterials AT kretzerjphilippe corrosionbehaviorofsurfacetreatedmetallicimplantmaterials |