Cargando…

Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods

Vessel diseases are often accompanied by abnormalities related to vascular shape and size. Therefore, a clear visualization of vasculature is of high clinical significance. Ultrasound color flow imaging (CFI) is one of the prominent techniques for flow visualization. However, clutter signals origina...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Naiyuan, Ashikuzzaman, Md, Rivaz, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7254711/
https://www.ncbi.nlm.nih.gov/pubmed/32466753
http://dx.doi.org/10.1186/s12938-020-00778-z
_version_ 1783539594413735936
author Zhang, Naiyuan
Ashikuzzaman, Md
Rivaz, Hassan
author_facet Zhang, Naiyuan
Ashikuzzaman, Md
Rivaz, Hassan
author_sort Zhang, Naiyuan
collection PubMed
description Vessel diseases are often accompanied by abnormalities related to vascular shape and size. Therefore, a clear visualization of vasculature is of high clinical significance. Ultrasound color flow imaging (CFI) is one of the prominent techniques for flow visualization. However, clutter signals originating from slow-moving tissue are one of the main obstacles to obtain a clear view of the vascular network. Enhancement of the vasculature by suppressing the clutters is a significant and irreplaceable step for many applications of ultrasound CFI. Currently, this task is often performed by singular value decomposition (SVD) of the data matrix. This approach exhibits two well-known limitations. First, the performance of SVD is sensitive to the proper manual selection of the ranks corresponding to clutter and blood subspaces. Second, SVD is prone to failure in the presence of large random noise in the dataset. A potential solution to these issues is using decomposition into low-rank and sparse matrices (DLSM) framework. SVD is one of the algorithms for solving the minimization problem under the DLSM framework. Many other algorithms under DLSM avoid full SVD and use approximated SVD or SVD-free ideas which may have better performance with higher robustness and less computing time. In practice, these models separate blood from clutter based on the assumption that steady clutter represents a low-rank structure and that the moving blood component is sparse. In this paper, we present a comprehensive review of ultrasound clutter suppression techniques and exploit the feasibility of low-rank and sparse decomposition schemes in ultrasound clutter suppression. We conduct this review study by adapting 106 DLSM algorithms and validating them against simulation, phantom, and in vivo rat datasets. Two conventional quality metrics, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), are used for performance evaluation. In addition, computation times required by different algorithms for generating clutter suppressed images are reported. Our extensive analysis shows that the DLSM framework can be successfully applied to ultrasound clutter suppression.
format Online
Article
Text
id pubmed-7254711
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72547112020-06-07 Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods Zhang, Naiyuan Ashikuzzaman, Md Rivaz, Hassan Biomed Eng Online Review Vessel diseases are often accompanied by abnormalities related to vascular shape and size. Therefore, a clear visualization of vasculature is of high clinical significance. Ultrasound color flow imaging (CFI) is one of the prominent techniques for flow visualization. However, clutter signals originating from slow-moving tissue are one of the main obstacles to obtain a clear view of the vascular network. Enhancement of the vasculature by suppressing the clutters is a significant and irreplaceable step for many applications of ultrasound CFI. Currently, this task is often performed by singular value decomposition (SVD) of the data matrix. This approach exhibits two well-known limitations. First, the performance of SVD is sensitive to the proper manual selection of the ranks corresponding to clutter and blood subspaces. Second, SVD is prone to failure in the presence of large random noise in the dataset. A potential solution to these issues is using decomposition into low-rank and sparse matrices (DLSM) framework. SVD is one of the algorithms for solving the minimization problem under the DLSM framework. Many other algorithms under DLSM avoid full SVD and use approximated SVD or SVD-free ideas which may have better performance with higher robustness and less computing time. In practice, these models separate blood from clutter based on the assumption that steady clutter represents a low-rank structure and that the moving blood component is sparse. In this paper, we present a comprehensive review of ultrasound clutter suppression techniques and exploit the feasibility of low-rank and sparse decomposition schemes in ultrasound clutter suppression. We conduct this review study by adapting 106 DLSM algorithms and validating them against simulation, phantom, and in vivo rat datasets. Two conventional quality metrics, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), are used for performance evaluation. In addition, computation times required by different algorithms for generating clutter suppressed images are reported. Our extensive analysis shows that the DLSM framework can be successfully applied to ultrasound clutter suppression. BioMed Central 2020-05-28 /pmc/articles/PMC7254711/ /pubmed/32466753 http://dx.doi.org/10.1186/s12938-020-00778-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Zhang, Naiyuan
Ashikuzzaman, Md
Rivaz, Hassan
Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title_full Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title_fullStr Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title_full_unstemmed Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title_short Clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
title_sort clutter suppression in ultrasound: performance evaluation and review of low-rank and sparse matrix decomposition methods
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7254711/
https://www.ncbi.nlm.nih.gov/pubmed/32466753
http://dx.doi.org/10.1186/s12938-020-00778-z
work_keys_str_mv AT zhangnaiyuan cluttersuppressioninultrasoundperformanceevaluationandreviewoflowrankandsparsematrixdecompositionmethods
AT ashikuzzamanmd cluttersuppressioninultrasoundperformanceevaluationandreviewoflowrankandsparsematrixdecompositionmethods
AT rivazhassan cluttersuppressioninultrasoundperformanceevaluationandreviewoflowrankandsparsematrixdecompositionmethods