Evaluation of the commercially available LightMix® Modular E-gene kit using clinical and proficiency testing specimens for SARS-CoV-2 detection
BACKGROUND: Rapid and sensitive diagnostic assays for SARS-CoV-2 detection are required for prompt patient management and infection control. The analytical and clinical performances of LightMix® Modular SARS and Wuhan CoV E-gene kit, a widely used commercial assay for SARS-CoV-2 detection, have not...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7255195/ https://www.ncbi.nlm.nih.gov/pubmed/32516739 http://dx.doi.org/10.1016/j.jcv.2020.104476 |
Sumario: | BACKGROUND: Rapid and sensitive diagnostic assays for SARS-CoV-2 detection are required for prompt patient management and infection control. The analytical and clinical performances of LightMix® Modular SARS and Wuhan CoV E-gene kit, a widely used commercial assay for SARS-CoV-2 detection, have not been well studied. OBJECTIVE: To evaluate the performance characteristics of the LightMix® E-gene kit in comparison with well-validated in-house developed COVID-19 RT-PCR assays. STUDY DESIGN: Serial dilutions of SARS-CoV-2 culture isolate extracts were used for analytical sensitivity evaluation. A total of 289 clinical specimens from 186 patients with suspected COVID-19 and 8 proficiency testing (PT) samples were used to evaluate the diagnostic performance of the LightMix® E-gene kit against in-house developed COVID-19-RdRp/Hel and COVID-19-N RT-PCR assays. RESULTS: The LightMix® E-gene kit had a limit of detection of 1.8 × 10(−1) TCID(50)/mL, which was one log(10) lower than those of the two in-house RT-PCR assays. The LightMix® E-gene kit (149/289 [51.6%]) had similar sensitivity as the in-house assays (144/289 [49.8%] for RdRp/Hel and 146/289 [50.5%] for N). All three assays gave correct results for all the PT samples. Cycle threshold (Cp) values of the LightMix® E-gene kit and in-house assays showed excellent correlation. Reproducibility of the Cp values was satisfactory with intra- and inter-assay coefficient of variation values <5%. Importantly, the LightMix® E-gene kit, when used as a stand-alone assay, was equally sensitive as testing algorithms using multiple COVID-19 RT-PCR assays. CONCLUSIONS: The LightMix® E-gene kit is a rapid and sensitive assay for SARS-CoV-2 detection. It has fewer verification requirements compared to laboratory-developed tests. |
---|