Cargando…

Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()

BACKGROUND: Patients with Tetralogy of Fallot (TOF) are at increased risk for sudden cardiac death, often undergo implantable cardioverter defibrillator (ICD) implantation at younger ages, and are at greater risk of experiencing inappropriate shocks. We investigated occurrences of ICD shocks in TOF...

Descripción completa

Detalles Bibliográficos
Autores principales: L.Goldenthal, Isaac, Rosenbaum, Marlon S., Lewis, Matthew, Sciacca, Robert R., Garan, Hasan, Biviano, Angelo B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7256636/
https://www.ncbi.nlm.nih.gov/pubmed/32490149
http://dx.doi.org/10.1016/j.ijcha.2020.100543
_version_ 1783539955132268544
author L.Goldenthal, Isaac
Rosenbaum, Marlon S.
Lewis, Matthew
Sciacca, Robert R.
Garan, Hasan
Biviano, Angelo B.
author_facet L.Goldenthal, Isaac
Rosenbaum, Marlon S.
Lewis, Matthew
Sciacca, Robert R.
Garan, Hasan
Biviano, Angelo B.
author_sort L.Goldenthal, Isaac
collection PubMed
description BACKGROUND: Patients with Tetralogy of Fallot (TOF) are at increased risk for sudden cardiac death, often undergo implantable cardioverter defibrillator (ICD) implantation at younger ages, and are at greater risk of experiencing inappropriate shocks. We investigated occurrences of ICD shocks in TOF patients to identify prevalence, characteristics associated with inappropriate shocks, and therapeutic interventions after inappropriate shocks. METHODS: Records of patients with repaired TOF and ICD implantation who were followed at Columbia University Irving Medical Center between 1/1/2000 and 5/1/2019 were analyzed. RESULTS: 44 patients with repaired TOF and ICD implantation were reviewed. Mean age at implantation was 39 ± 13 years. Eight (18%) patients received both appropriate and inappropriate shocks, 6 (14%) received only appropriate shocks, and 3 (7%) received only inappropriate shocks. Three patients received inappropriate shocks for sinus tachycardia, 7 for atrial arrhythmias, and 1 for noise artifact. Inappropriately shocked patients had lower beat per minute (bpm) cutoff values for ICD therapy (mean = 162 ± 24 bpm vs. 182 ± 16 bpm, p = 0.007). After inappropriate shocks, 1 patient underwent lead replacement, 1 had the VT cutoff increased, and 6 were treated with medications. CONCLUSIONS: One quarter of TOF patients with ICDs experienced inappropriate shock therapy, the timing of which was most often clustered within the first two years after implant or years later. Lower shock therapy zones were associated with increased risk for inappropriate shocks, and the majority of inappropriate shocks resulted from atrial arrhythmias with rapid ventricular response. Treatments for inappropriate shocks included increasing VT therapy bpm and rhythm and/or rate control medications.
format Online
Article
Text
id pubmed-7256636
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72566362020-06-01 Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms() L.Goldenthal, Isaac Rosenbaum, Marlon S. Lewis, Matthew Sciacca, Robert R. Garan, Hasan Biviano, Angelo B. Int J Cardiol Heart Vasc Original Paper BACKGROUND: Patients with Tetralogy of Fallot (TOF) are at increased risk for sudden cardiac death, often undergo implantable cardioverter defibrillator (ICD) implantation at younger ages, and are at greater risk of experiencing inappropriate shocks. We investigated occurrences of ICD shocks in TOF patients to identify prevalence, characteristics associated with inappropriate shocks, and therapeutic interventions after inappropriate shocks. METHODS: Records of patients with repaired TOF and ICD implantation who were followed at Columbia University Irving Medical Center between 1/1/2000 and 5/1/2019 were analyzed. RESULTS: 44 patients with repaired TOF and ICD implantation were reviewed. Mean age at implantation was 39 ± 13 years. Eight (18%) patients received both appropriate and inappropriate shocks, 6 (14%) received only appropriate shocks, and 3 (7%) received only inappropriate shocks. Three patients received inappropriate shocks for sinus tachycardia, 7 for atrial arrhythmias, and 1 for noise artifact. Inappropriately shocked patients had lower beat per minute (bpm) cutoff values for ICD therapy (mean = 162 ± 24 bpm vs. 182 ± 16 bpm, p = 0.007). After inappropriate shocks, 1 patient underwent lead replacement, 1 had the VT cutoff increased, and 6 were treated with medications. CONCLUSIONS: One quarter of TOF patients with ICDs experienced inappropriate shock therapy, the timing of which was most often clustered within the first two years after implant or years later. Lower shock therapy zones were associated with increased risk for inappropriate shocks, and the majority of inappropriate shocks resulted from atrial arrhythmias with rapid ventricular response. Treatments for inappropriate shocks included increasing VT therapy bpm and rhythm and/or rate control medications. Elsevier 2020-05-26 /pmc/articles/PMC7256636/ /pubmed/32490149 http://dx.doi.org/10.1016/j.ijcha.2020.100543 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Paper
L.Goldenthal, Isaac
Rosenbaum, Marlon S.
Lewis, Matthew
Sciacca, Robert R.
Garan, Hasan
Biviano, Angelo B.
Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title_full Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title_fullStr Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title_full_unstemmed Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title_short Inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: Prevalence and electrophysiological mechanisms()
title_sort inappropriate implantable cardioverter-defibrillator shocks in repaired tetralogy of fallot patients: prevalence and electrophysiological mechanisms()
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7256636/
https://www.ncbi.nlm.nih.gov/pubmed/32490149
http://dx.doi.org/10.1016/j.ijcha.2020.100543
work_keys_str_mv AT lgoldenthalisaac inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms
AT rosenbaummarlons inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms
AT lewismatthew inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms
AT sciaccarobertr inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms
AT garanhasan inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms
AT bivianoangelob inappropriateimplantablecardioverterdefibrillatorshocksinrepairedtetralogyoffallotpatientsprevalenceandelectrophysiologicalmechanisms