Cargando…

Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox

Explosive penetration of veno-arterial extracorporeal life support in everyday practice has drawn awareness to complications of peripheral cannulation, resulting in recommendations to use smaller size cannulae. However, using smaller cannulae may limit the effectiveness of extracorporeal support and...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganushchak, Yuri M, Kurniawati, Eva R, Maessen, Jos G, Weerwind, Patrick W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7263036/
https://www.ncbi.nlm.nih.gov/pubmed/31709887
http://dx.doi.org/10.1177/0267659119885586
_version_ 1783540734535663616
author Ganushchak, Yuri M
Kurniawati, Eva R
Maessen, Jos G
Weerwind, Patrick W
author_facet Ganushchak, Yuri M
Kurniawati, Eva R
Maessen, Jos G
Weerwind, Patrick W
author_sort Ganushchak, Yuri M
collection PubMed
description Explosive penetration of veno-arterial extracorporeal life support in everyday practice has drawn awareness to complications of peripheral cannulation, resulting in recommendations to use smaller size cannulae. However, using smaller cannulae may limit the effectiveness of extracorporeal support and thereby the specific needs of the patient. Selection of proper size cannulae may therefore pose a dilemma, especially since pressure-flow characteristics at different hematocrits are lacking. This study evaluates the precision of cannula pressure drop prediction with increase of fluid viscosity from water flow-pressure charts by M-number, dynamic similarity law, and via fitted parabolic equation. Thirteen commercially available peripheral cannulae were used in this in vitro study. Pressure drop and flow were recorded using water and a water-glycerol solution as a surrogate for blood, at ambient temperature. Subsequently, pressure-flow curves were modeled with increased fluid viscosity (0.0031 N s m(−2)), and then compared by M-number, dynamic similarity law, and fitted parabolic equation. The agreement of predicted and measured values were significantly higher when the M-number (concordance correlation = 0.948), and the dynamic similarity law method (concordance correlation = 0.947) was used in comparison to the fitted parabolic equation (concordance correlation = 0.898, p < 0.01). The M-number and dynamic similarity based model allow for reliable prediction of peripheral cannula pressure drop with changes of fluid viscosity and could therefore aid in well-thought-out selection of cannulae for extracorporeal life support.
format Online
Article
Text
id pubmed-7263036
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-72630362020-06-23 Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox Ganushchak, Yuri M Kurniawati, Eva R Maessen, Jos G Weerwind, Patrick W Perfusion Original Papers Explosive penetration of veno-arterial extracorporeal life support in everyday practice has drawn awareness to complications of peripheral cannulation, resulting in recommendations to use smaller size cannulae. However, using smaller cannulae may limit the effectiveness of extracorporeal support and thereby the specific needs of the patient. Selection of proper size cannulae may therefore pose a dilemma, especially since pressure-flow characteristics at different hematocrits are lacking. This study evaluates the precision of cannula pressure drop prediction with increase of fluid viscosity from water flow-pressure charts by M-number, dynamic similarity law, and via fitted parabolic equation. Thirteen commercially available peripheral cannulae were used in this in vitro study. Pressure drop and flow were recorded using water and a water-glycerol solution as a surrogate for blood, at ambient temperature. Subsequently, pressure-flow curves were modeled with increased fluid viscosity (0.0031 N s m(−2)), and then compared by M-number, dynamic similarity law, and fitted parabolic equation. The agreement of predicted and measured values were significantly higher when the M-number (concordance correlation = 0.948), and the dynamic similarity law method (concordance correlation = 0.947) was used in comparison to the fitted parabolic equation (concordance correlation = 0.898, p < 0.01). The M-number and dynamic similarity based model allow for reliable prediction of peripheral cannula pressure drop with changes of fluid viscosity and could therefore aid in well-thought-out selection of cannulae for extracorporeal life support. SAGE Publications 2019-11-10 2020-05 /pmc/articles/PMC7263036/ /pubmed/31709887 http://dx.doi.org/10.1177/0267659119885586 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Papers
Ganushchak, Yuri M
Kurniawati, Eva R
Maessen, Jos G
Weerwind, Patrick W
Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title_full Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title_fullStr Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title_full_unstemmed Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title_short Peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
title_sort peripheral cannulae selection for veno-arterial extracorporeal life support: a paradox
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7263036/
https://www.ncbi.nlm.nih.gov/pubmed/31709887
http://dx.doi.org/10.1177/0267659119885586
work_keys_str_mv AT ganushchakyurim peripheralcannulaeselectionforvenoarterialextracorporeallifesupportaparadox
AT kurniawatievar peripheralcannulaeselectionforvenoarterialextracorporeallifesupportaparadox
AT maessenjosg peripheralcannulaeselectionforvenoarterialextracorporeallifesupportaparadox
AT weerwindpatrickw peripheralcannulaeselectionforvenoarterialextracorporeallifesupportaparadox