Cargando…

Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique

PURPOSE: The purpose of this study is to evaluate and compare the correlation between changes in vision and HD Analyzer dual-pass metrics versus changes in vision and conventional subjective slit lamp gradings in pseudophakic patients with posterior capsular opacity undergoing neodymium:yttrium-alum...

Descripción completa

Detalles Bibliográficos
Autores principales: Zafar, Abu-Bakar, Chu, Richard C, Bishara, Miranda N, Qazi, Mujtaba A, Mahmoud, Ashraf M, Pepose, Jay S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7266399/
https://www.ncbi.nlm.nih.gov/pubmed/32546948
http://dx.doi.org/10.2147/OPTH.S248286
_version_ 1783541300679671808
author Zafar, Abu-Bakar
Chu, Richard C
Bishara, Miranda N
Qazi, Mujtaba A
Mahmoud, Ashraf M
Pepose, Jay S
author_facet Zafar, Abu-Bakar
Chu, Richard C
Bishara, Miranda N
Qazi, Mujtaba A
Mahmoud, Ashraf M
Pepose, Jay S
author_sort Zafar, Abu-Bakar
collection PubMed
description PURPOSE: The purpose of this study is to evaluate and compare the correlation between changes in vision and HD Analyzer dual-pass metrics versus changes in vision and conventional subjective slit lamp gradings in pseudophakic patients with posterior capsular opacity undergoing neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy. PATIENTS AND METHODS: High contrast (HC) and low contrast (LC) best spectacle-corrected distance visual acuity (BCVA) and HD Analyzer evaluation were prospectively performed on patients with mild-to-moderate posterior capsular opacification (PCO) and monofocal and accommodating intraocular lens implants. Differences between pre- and post-operative measurements were calculated, along with the correlation of HD Analyzer metrics and slit lamp grading to changes in visual acuity. RESULTS: Following Nd:YAG capsulotomy (n=29), there was statistically significant improvement in HC-BCVA and LC-BCVA, decrease in optical scatter, and corresponding improvement in Strehl ratio and HD Analyzer values at all contrast levels tested (p≤0.05). Pearson test showed a high correlation between the improvement in HC-BCVA (r coefficient = 0.78) and LC-BCVA (r coefficient = 0.71) to the improvement in Objective Scatter Index (OSI). There was a higher correlation of change in HC-BCVA to pre-op OSI  (r(2)=0.61) than to the subjective PCO grading score (r(2) = 0.19). There was also a higher correlation of change in LC-BCVA to pre-op OSI (r(2) = 0.49) than to subjective grading (r(2) = 0.16). CONCLUSION: The HD Analyzer provides objective measurements of forward light scatter (ie, light directed towards the retina) that can assist with both PCO grading and prediction of improvement of visual quality after YAG laser capsulotomy with higher accuracy than conventional slit lamp assessment based upon backscatter (ie, light traveling to the observer) in patients tested with monofocal and accommodating intraocular lens implants.
format Online
Article
Text
id pubmed-7266399
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-72663992020-06-15 Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique Zafar, Abu-Bakar Chu, Richard C Bishara, Miranda N Qazi, Mujtaba A Mahmoud, Ashraf M Pepose, Jay S Clin Ophthalmol Original Research PURPOSE: The purpose of this study is to evaluate and compare the correlation between changes in vision and HD Analyzer dual-pass metrics versus changes in vision and conventional subjective slit lamp gradings in pseudophakic patients with posterior capsular opacity undergoing neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy. PATIENTS AND METHODS: High contrast (HC) and low contrast (LC) best spectacle-corrected distance visual acuity (BCVA) and HD Analyzer evaluation were prospectively performed on patients with mild-to-moderate posterior capsular opacification (PCO) and monofocal and accommodating intraocular lens implants. Differences between pre- and post-operative measurements were calculated, along with the correlation of HD Analyzer metrics and slit lamp grading to changes in visual acuity. RESULTS: Following Nd:YAG capsulotomy (n=29), there was statistically significant improvement in HC-BCVA and LC-BCVA, decrease in optical scatter, and corresponding improvement in Strehl ratio and HD Analyzer values at all contrast levels tested (p≤0.05). Pearson test showed a high correlation between the improvement in HC-BCVA (r coefficient = 0.78) and LC-BCVA (r coefficient = 0.71) to the improvement in Objective Scatter Index (OSI). There was a higher correlation of change in HC-BCVA to pre-op OSI  (r(2)=0.61) than to the subjective PCO grading score (r(2) = 0.19). There was also a higher correlation of change in LC-BCVA to pre-op OSI (r(2) = 0.49) than to subjective grading (r(2) = 0.16). CONCLUSION: The HD Analyzer provides objective measurements of forward light scatter (ie, light directed towards the retina) that can assist with both PCO grading and prediction of improvement of visual quality after YAG laser capsulotomy with higher accuracy than conventional slit lamp assessment based upon backscatter (ie, light traveling to the observer) in patients tested with monofocal and accommodating intraocular lens implants. Dove 2020-05-26 /pmc/articles/PMC7266399/ /pubmed/32546948 http://dx.doi.org/10.2147/OPTH.S248286 Text en © 2020 Zafar et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Zafar, Abu-Bakar
Chu, Richard C
Bishara, Miranda N
Qazi, Mujtaba A
Mahmoud, Ashraf M
Pepose, Jay S
Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title_full Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title_fullStr Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title_full_unstemmed Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title_short Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique
title_sort objective quantification of image quality and optical scatter before and after nd:yag capsulotomy using a double-pass technique
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7266399/
https://www.ncbi.nlm.nih.gov/pubmed/32546948
http://dx.doi.org/10.2147/OPTH.S248286
work_keys_str_mv AT zafarabubakar objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique
AT churichardc objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique
AT bisharamirandan objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique
AT qazimujtabaa objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique
AT mahmoudashrafm objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique
AT peposejays objectivequantificationofimagequalityandopticalscatterbeforeandafterndyagcapsulotomyusingadoublepasstechnique