Cargando…

Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits

BACKGROUND: Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) and diffusion tensor imaging (DTI) are useful methods for investigating the morphology and function of the kidneys, including revealing unilateral renal damage. Nevertheless, these techniques have not yet been applie...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Zhiqiang, Liu, Hongxu, Meng, Heng, Zhang, Duo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7268285/
https://www.ncbi.nlm.nih.gov/pubmed/32493274
http://dx.doi.org/10.1186/s12882-020-01857-y
_version_ 1783541583384150016
author Wang, Zhiqiang
Liu, Hongxu
Meng, Heng
Zhang, Duo
author_facet Wang, Zhiqiang
Liu, Hongxu
Meng, Heng
Zhang, Duo
author_sort Wang, Zhiqiang
collection PubMed
description BACKGROUND: Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) and diffusion tensor imaging (DTI) are useful methods for investigating the morphology and function of the kidneys, including revealing unilateral renal damage. Nevertheless, these techniques have not yet been applied for bilateral renal function. The aim of this study was to investigate whether the combination of DTI and BOLD could be used to examine different degrees of contrast-induced acute kidney injury (CI-AKI) in bilateral kidneys compared to standard methods such as serum creatinine (SCr) detection. METHODS: Forty-Two New Zealand white rabbits were divided into two groups: the experimental group and the control group. Physiological saline and iodine contrast agent (iohexol, 1.0 g iodine/kg, 1.0 ml/sec) were injected via the right renal artery. DTI and BOLD-MR data were acquired longitudinally at the baseline and 1, 24, 48, and 72 h after high-pressure syringe injection to measure the apparent diffusion coefficient (ADC), fractional anisotropy (FA) and relative transverse relaxation rate (R2*). After the MR scan at each time point, three rabbits in each group were sacrificed, and changes in SCr and hypoxia-inducible factor-1α (HIF-1α) were analyzed using histopathology and immunochemistry. RESULTS: Twenty-four hours after iohexol administration, the values of ADC and FA decreased significantly (P < 0.05), while R2* values increased (P < 0.05) in the renal cortex (CO), outer medulla (OM) and inner medulla (IM). Besides, significant negative correlations were observed among ADC, FA, and R2* in CO, OM, and IM (all P < 0.001, r = − 0.654–0.828). CONCLUSIONS: DTI and BOLD can simultaneously and non-invasively assess different degrees of CI-AKI in bilateral kidneys.
format Online
Article
Text
id pubmed-7268285
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72682852020-06-07 Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits Wang, Zhiqiang Liu, Hongxu Meng, Heng Zhang, Duo BMC Nephrol Research Article BACKGROUND: Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) and diffusion tensor imaging (DTI) are useful methods for investigating the morphology and function of the kidneys, including revealing unilateral renal damage. Nevertheless, these techniques have not yet been applied for bilateral renal function. The aim of this study was to investigate whether the combination of DTI and BOLD could be used to examine different degrees of contrast-induced acute kidney injury (CI-AKI) in bilateral kidneys compared to standard methods such as serum creatinine (SCr) detection. METHODS: Forty-Two New Zealand white rabbits were divided into two groups: the experimental group and the control group. Physiological saline and iodine contrast agent (iohexol, 1.0 g iodine/kg, 1.0 ml/sec) were injected via the right renal artery. DTI and BOLD-MR data were acquired longitudinally at the baseline and 1, 24, 48, and 72 h after high-pressure syringe injection to measure the apparent diffusion coefficient (ADC), fractional anisotropy (FA) and relative transverse relaxation rate (R2*). After the MR scan at each time point, three rabbits in each group were sacrificed, and changes in SCr and hypoxia-inducible factor-1α (HIF-1α) were analyzed using histopathology and immunochemistry. RESULTS: Twenty-four hours after iohexol administration, the values of ADC and FA decreased significantly (P < 0.05), while R2* values increased (P < 0.05) in the renal cortex (CO), outer medulla (OM) and inner medulla (IM). Besides, significant negative correlations were observed among ADC, FA, and R2* in CO, OM, and IM (all P < 0.001, r = − 0.654–0.828). CONCLUSIONS: DTI and BOLD can simultaneously and non-invasively assess different degrees of CI-AKI in bilateral kidneys. BioMed Central 2020-06-03 /pmc/articles/PMC7268285/ /pubmed/32493274 http://dx.doi.org/10.1186/s12882-020-01857-y Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Wang, Zhiqiang
Liu, Hongxu
Meng, Heng
Zhang, Duo
Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title_full Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title_fullStr Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title_full_unstemmed Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title_short Application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by Iohexol in rabbits
title_sort application of diffusion tensor imaging and blood oxygenation level-dependent magnetic resonance imaging to assess bilateral renal function induced by iohexol in rabbits
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7268285/
https://www.ncbi.nlm.nih.gov/pubmed/32493274
http://dx.doi.org/10.1186/s12882-020-01857-y
work_keys_str_mv AT wangzhiqiang applicationofdiffusiontensorimagingandbloodoxygenationleveldependentmagneticresonanceimagingtoassessbilateralrenalfunctioninducedbyiohexolinrabbits
AT liuhongxu applicationofdiffusiontensorimagingandbloodoxygenationleveldependentmagneticresonanceimagingtoassessbilateralrenalfunctioninducedbyiohexolinrabbits
AT mengheng applicationofdiffusiontensorimagingandbloodoxygenationleveldependentmagneticresonanceimagingtoassessbilateralrenalfunctioninducedbyiohexolinrabbits
AT zhangduo applicationofdiffusiontensorimagingandbloodoxygenationleveldependentmagneticresonanceimagingtoassessbilateralrenalfunctioninducedbyiohexolinrabbits