Using force data to self-pace an instrumented treadmill and measure self-selected walking speed

BACKGROUND: Self-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. METHODS: We adapted a previously proposed self-pacing...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Seungmoon, Choi, Hojung, Collins, Steven H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7268460/
https://www.ncbi.nlm.nih.gov/pubmed/32493426
http://dx.doi.org/10.1186/s12984-020-00683-5
Descripción
Sumario:BACKGROUND: Self-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. METHODS: We adapted a previously proposed self-pacing controller for force-instrumented treadmills and validated its use for measuring self-selected speeds. We first evaluated the controller’s estimation of subject speed and position from the force-plates by comparing it to those from motion capture data. We then compared five tests of self-selected speed. Ten healthy adults completed a standard 10-meter walk test, a 150-meter walk test, a commonly used manual treadmill speed selection test, a two-minute self-paced treadmill test, and a 150-meter self-paced treadmill test. In each case, subjects were instructed to walk at or select their comfortable speed. We also assessed the time taken for a trial and a survey on comfort and ease of choosing a speed in all the tests. RESULTS: The self-pacing algorithm estimated subject speed and position accurately, with root mean square differences compared to motion capture of 0.023 m s (−1) and 0.014 m, respectively. Self-selected speeds from both self-paced treadmill tests correlated well with those from the 10-meter walk test (R>0.93,p<1×10(−13)). Subjects walked slower on average in the self-paced treadmill tests (1.23±0.27 ms(−1)) than in the 10-meter walk test (1.32±0.18 ms(−1)) but the speed differences within subjects were consistent. These correlations and walking speeds are comparable to those from the manual treadmill speed selection test (R=0.89,p=3×10(−11);1.18±0.24 ms(−1)). Comfort and ease of speed selection were similar in the self-paced tests and the manual speed selection test, but the self-paced tests required only about a third of the time to complete. Our results demonstrate that these self-paced treadmill tests can be a strong alternative to the commonly used manual treadmill speed selection test. CONCLUSIONS: The self-paced force-instrumented treadmill well adapts to subject walking speed and reliably measures self-selected walking speeds. We provide the self-pacing software to facilitate use by gait researchers and clinicians.