Cargando…

Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial

AIMS AND OBJECTIVES: The use of polyaxial locking plates is an established technique for the treatment of proximal tibia fractures. At the moment different polyaxial locking implants from numerous manufactures are available, though at the moment there are no clinical trials regarding their differenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Völk, Dominik, Neumaier, Markus, Einhellig, Heike, Biberthaler, Peter, Hanschen, Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7268569/
http://dx.doi.org/10.1177/2325967120S00316
_version_ 1783541645712556032
author Völk, Dominik
Neumaier, Markus
Einhellig, Heike
Biberthaler, Peter
Hanschen, Marc
author_facet Völk, Dominik
Neumaier, Markus
Einhellig, Heike
Biberthaler, Peter
Hanschen, Marc
author_sort Völk, Dominik
collection PubMed
description AIMS AND OBJECTIVES: The use of polyaxial locking plates is an established technique for the treatment of proximal tibia fractures. At the moment different polyaxial locking implants from numerous manufactures are available, though at the moment there are no clinical trials regarding their differences. In this prospective clinical trail we compared the NCB-PT® (Zimmer) and the VA-LCP® (Synthes) by analysing primary and secondary quality criteria of the osteosynthesis (clinical and radiological). MATERIALS AND METHODS: This study enrolled 28 patients suffering from a proximal tibia fracture (AO/ASIF 41 B-C). The follow-up examinations were conducted over 12 months after the surgery. Clinical (e.g. range of motion, Rasmussen score, Tegner score) as well as radiological parameters (e.g. primary and secondary loss of reduction, fracture healing) were collected. For the analysis of continuous parametric variables the Student’s t-test was used and for non-parametric variables the Mann-Whitney U test. For binominal variables the Fisher’s exact test was preformed. In all analysis the significance level was set at a p-value <0,05. RESULTS: Comparing the epidemiologic data of both groups only very small or no differences with no statistical significance could be found. The intraoperative data showed a significant longer surgery duration for the NCB-group (NCB-PT® 196,3 min vs. VA-LCP® 121,7 min, p-value 0,0335). Furthermore the median length of implants used in each group proved to be significant longer in the NCB-group (NCB-PT® 8,1 holes vs. VA-LCP® 5,1 holes, p-value 0,0007), most likely because of the imbalance of severe fractures in between the groups (type C fractures: NCB-PT® 78% vs. VA-LCP® 26%). The analysis of the clinical data as well as the clinical scores showed reduced scoring values of the NCB-group. Only the results of the Lysholm score (p-value: 0,03) and MKQ (Munich Knee Questionnaire) (p-value: < 0,0001) proved to be statistically significant. Regarding the radiological data only the radiologic Rasmussen score had a significant difference in favour of the VA-LCP®-group (p-value 0,0153). CONCLUSION: This study constitutes the first prospective clinical trial to compare the outcome of the VALCP® an NCB-PT® for the treatment of proximal tibia fractures. Despite the limitation of this study, low case numbers and heterogeneity of fracture types, differences regarding the clinical and radiological outcome could be found. The treatment with the VA-LCP® had a significantsuperior outcome in separate clinical scores (Lyshom score/ Munich Knee Questionnaire) as well as in a single radiologic score (radiologic Rasmussen score) in comparison to the treatment with the NCB-PT®. Our data underlines the necessity for an extended study with a higher case number.
format Online
Article
Text
id pubmed-7268569
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-72685692020-06-11 Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial Völk, Dominik Neumaier, Markus Einhellig, Heike Biberthaler, Peter Hanschen, Marc Orthop J Sports Med Article AIMS AND OBJECTIVES: The use of polyaxial locking plates is an established technique for the treatment of proximal tibia fractures. At the moment different polyaxial locking implants from numerous manufactures are available, though at the moment there are no clinical trials regarding their differences. In this prospective clinical trail we compared the NCB-PT® (Zimmer) and the VA-LCP® (Synthes) by analysing primary and secondary quality criteria of the osteosynthesis (clinical and radiological). MATERIALS AND METHODS: This study enrolled 28 patients suffering from a proximal tibia fracture (AO/ASIF 41 B-C). The follow-up examinations were conducted over 12 months after the surgery. Clinical (e.g. range of motion, Rasmussen score, Tegner score) as well as radiological parameters (e.g. primary and secondary loss of reduction, fracture healing) were collected. For the analysis of continuous parametric variables the Student’s t-test was used and for non-parametric variables the Mann-Whitney U test. For binominal variables the Fisher’s exact test was preformed. In all analysis the significance level was set at a p-value <0,05. RESULTS: Comparing the epidemiologic data of both groups only very small or no differences with no statistical significance could be found. The intraoperative data showed a significant longer surgery duration for the NCB-group (NCB-PT® 196,3 min vs. VA-LCP® 121,7 min, p-value 0,0335). Furthermore the median length of implants used in each group proved to be significant longer in the NCB-group (NCB-PT® 8,1 holes vs. VA-LCP® 5,1 holes, p-value 0,0007), most likely because of the imbalance of severe fractures in between the groups (type C fractures: NCB-PT® 78% vs. VA-LCP® 26%). The analysis of the clinical data as well as the clinical scores showed reduced scoring values of the NCB-group. Only the results of the Lysholm score (p-value: 0,03) and MKQ (Munich Knee Questionnaire) (p-value: < 0,0001) proved to be statistically significant. Regarding the radiological data only the radiologic Rasmussen score had a significant difference in favour of the VA-LCP®-group (p-value 0,0153). CONCLUSION: This study constitutes the first prospective clinical trial to compare the outcome of the VALCP® an NCB-PT® for the treatment of proximal tibia fractures. Despite the limitation of this study, low case numbers and heterogeneity of fracture types, differences regarding the clinical and radiological outcome could be found. The treatment with the VA-LCP® had a significantsuperior outcome in separate clinical scores (Lyshom score/ Munich Knee Questionnaire) as well as in a single radiologic score (radiologic Rasmussen score) in comparison to the treatment with the NCB-PT®. Our data underlines the necessity for an extended study with a higher case number. SAGE Publications 2020-05-29 /pmc/articles/PMC7268569/ http://dx.doi.org/10.1177/2325967120S00316 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Völk, Dominik
Neumaier, Markus
Einhellig, Heike
Biberthaler, Peter
Hanschen, Marc
Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title_full Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title_fullStr Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title_full_unstemmed Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title_short Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (VALCP ® vs. NCB-PT®): a prospective randomized clinical trial
title_sort outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures (valcp ® vs. ncb-pt®): a prospective randomized clinical trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7268569/
http://dx.doi.org/10.1177/2325967120S00316
work_keys_str_mv AT volkdominik outcomeafterpolyaxiallockingplateosteosynthesisinproximaltibiafracturesvalcpvsncbptaprospectiverandomizedclinicaltrial
AT neumaiermarkus outcomeafterpolyaxiallockingplateosteosynthesisinproximaltibiafracturesvalcpvsncbptaprospectiverandomizedclinicaltrial
AT einhelligheike outcomeafterpolyaxiallockingplateosteosynthesisinproximaltibiafracturesvalcpvsncbptaprospectiverandomizedclinicaltrial
AT biberthalerpeter outcomeafterpolyaxiallockingplateosteosynthesisinproximaltibiafracturesvalcpvsncbptaprospectiverandomizedclinicaltrial
AT hanschenmarc outcomeafterpolyaxiallockingplateosteosynthesisinproximaltibiafracturesvalcpvsncbptaprospectiverandomizedclinicaltrial