Cargando…
Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality
The ectopic renal function estimation based on a manual region of interest (ROI) extraction could be considered as time consuming. It could also affect the clinical interpretation and thus deviate the therapeutic attitude. For this purpose, we propose an advanced tool to evaluate such function throu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7271057/ https://www.ncbi.nlm.nih.gov/pubmed/32566114 http://dx.doi.org/10.1155/2020/6092305 |
_version_ | 1783542018362834944 |
---|---|
author | Njeh, Ines Chtourou, Kalil BenHamida, Ahmed |
author_facet | Njeh, Ines Chtourou, Kalil BenHamida, Ahmed |
author_sort | Njeh, Ines |
collection | PubMed |
description | The ectopic renal function estimation based on a manual region of interest (ROI) extraction could be considered as time consuming. It could also affect the clinical interpretation and thus deviate the therapeutic attitude. For this purpose, we propose an advanced tool to evaluate such function through the dimercaptosuccinic acid (DMSA) kidney scintigraphy scans. Methods. The proposed study has been performed on one hundred patients (fifty cases with normal kidneys and fifty cases with ectopic kidneys). We present our segmentation problems as several cost functions' optimization, each containing two terms: (i) a distribution matching prior, which evaluates a global similarity between distributions, and (ii) a smoothness prior to avoid the occurrence of small, isolated regions in the solution. Obtained following recent bound-relaxation results, the optima of the cost functions yield each kidney region in near real time. The Dice Metric (DM), the Jaccard Index (JI), and the correlation parameter have been adopted as validation parameters in order to evaluate the segmentation results. The obtained relative function of both kidneys has been then compared with that evaluated in clinical routine (planar projection) and then validated statistically by the Bland–Altman plots and the Interclass Correlation Coefficient (ICC). Results. Compared to the expert's manual kidney segmentation, the obtained results have been judged to be acceptable for clinical use with high Mean Dice Metric (MDM) value and high Jaccard Index (JI). The evaluated relative renal function has been different from those calculated by the projection planar method usually used in clinical routines. Conclusion. The proposed system could efficiently extract the renal region. The relative function estimation could be considered as more accurate. In fact, the background noise correction and the attenuation phenomenon, which could yield an error measure for renal ectopia, have been avoided. Our clinical staff members have validated the results and have suggested using such tool in their clinical routines. |
format | Online Article Text |
id | pubmed-7271057 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-72710572020-06-18 Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality Njeh, Ines Chtourou, Kalil BenHamida, Ahmed J Healthc Eng Research Article The ectopic renal function estimation based on a manual region of interest (ROI) extraction could be considered as time consuming. It could also affect the clinical interpretation and thus deviate the therapeutic attitude. For this purpose, we propose an advanced tool to evaluate such function through the dimercaptosuccinic acid (DMSA) kidney scintigraphy scans. Methods. The proposed study has been performed on one hundred patients (fifty cases with normal kidneys and fifty cases with ectopic kidneys). We present our segmentation problems as several cost functions' optimization, each containing two terms: (i) a distribution matching prior, which evaluates a global similarity between distributions, and (ii) a smoothness prior to avoid the occurrence of small, isolated regions in the solution. Obtained following recent bound-relaxation results, the optima of the cost functions yield each kidney region in near real time. The Dice Metric (DM), the Jaccard Index (JI), and the correlation parameter have been adopted as validation parameters in order to evaluate the segmentation results. The obtained relative function of both kidneys has been then compared with that evaluated in clinical routine (planar projection) and then validated statistically by the Bland–Altman plots and the Interclass Correlation Coefficient (ICC). Results. Compared to the expert's manual kidney segmentation, the obtained results have been judged to be acceptable for clinical use with high Mean Dice Metric (MDM) value and high Jaccard Index (JI). The evaluated relative renal function has been different from those calculated by the projection planar method usually used in clinical routines. Conclusion. The proposed system could efficiently extract the renal region. The relative function estimation could be considered as more accurate. In fact, the background noise correction and the attenuation phenomenon, which could yield an error measure for renal ectopia, have been avoided. Our clinical staff members have validated the results and have suggested using such tool in their clinical routines. Hindawi 2020-05-26 /pmc/articles/PMC7271057/ /pubmed/32566114 http://dx.doi.org/10.1155/2020/6092305 Text en Copyright © 2020 Ines Njeh et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Njeh, Ines Chtourou, Kalil BenHamida, Ahmed Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title | Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title_full | Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title_fullStr | Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title_full_unstemmed | Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title_short | Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality |
title_sort | relative ectopic kidney function quantification using dmsa tomoscintigraphy modality |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7271057/ https://www.ncbi.nlm.nih.gov/pubmed/32566114 http://dx.doi.org/10.1155/2020/6092305 |
work_keys_str_mv | AT njehines relativeectopickidneyfunctionquantificationusingdmsatomoscintigraphymodality AT chtouroukalil relativeectopickidneyfunctionquantificationusingdmsatomoscintigraphymodality AT benhamidaahmed relativeectopickidneyfunctionquantificationusingdmsatomoscintigraphymodality |