Cargando…

Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification

[Image: see text] Isobaric peptide termini labeling (IPTL) is an attractive protein quantification method because it provides more accurate and reliable quantification information than traditional isobaric labeling methods (e.g., TMT and iTRAQ) by making use of the entire fragment-ion series instead...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Xiaobo, de Vries, Marcel P., Visscher, Susan W. J., Permentier, Hjalmar P., Bischoff, Rainer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7271076/
https://www.ncbi.nlm.nih.gov/pubmed/32319746
http://dx.doi.org/10.1021/acs.analchem.0c01059
_version_ 1783542021425725440
author Tian, Xiaobo
de Vries, Marcel P.
Visscher, Susan W. J.
Permentier, Hjalmar P.
Bischoff, Rainer
author_facet Tian, Xiaobo
de Vries, Marcel P.
Visscher, Susan W. J.
Permentier, Hjalmar P.
Bischoff, Rainer
author_sort Tian, Xiaobo
collection PubMed
description [Image: see text] Isobaric peptide termini labeling (IPTL) is an attractive protein quantification method because it provides more accurate and reliable quantification information than traditional isobaric labeling methods (e.g., TMT and iTRAQ) by making use of the entire fragment-ion series instead of only a single reporter ion. The multiplexing capacity of published IPTL implementations is, however, limited to three. Here, we present a selective maleylation-directed isobaric peptide termini labeling (SMD-IPTL) approach for quantitative proteomics of LysC protein digestion. SMD-IPTL extends the multiplexing capacity to 4-plex with the potential for higher levels of multiplexing using commercially available (13)C/(15)N labeled amino acids. SMD-IPTL is achieved in a one-pot reaction in three consecutive steps: (1) selective maleylation at the N-terminus; (2) labeling at the ε-NH(2) group of the C-terminal Lys with isotopically labeled acetyl-alanine; (3) thiol Michael addition of an isotopically labeled acetyl-cysteine at the maleylated N-terminus. The isobarically labeled peptides are fragmented into sets of b- and y-ion clusters upon LC-MS/MS, which convey not only sequence information but also quantitative information for every labeling channel and avoid the issue of ratio distortion observed with reporter-ion-based approaches. We demonstrate the SMD-IPTL approach with a 4-plex labeled sample of bovine serum albumin (BSA) and yeast lysates mixed at different ratios. With the use of SMD-IPTL for labeling and a narrow precursor isolation window of 0.8 Th with an offset of −0.2 Th, accurate ratios were measured across a 10-fold mixing range of BSA in a background of yeast proteome. With the yeast proteins mixed at ratios of 1:5:1:5, BSA was detected at ratios of 0.94:2.46:4.70:9.92 when spiked at 1:2:5:10 ratios with an average standard deviation of peptide ratios of 0.34.
format Online
Article
Text
id pubmed-7271076
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-72710762020-06-05 Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification Tian, Xiaobo de Vries, Marcel P. Visscher, Susan W. J. Permentier, Hjalmar P. Bischoff, Rainer Anal Chem [Image: see text] Isobaric peptide termini labeling (IPTL) is an attractive protein quantification method because it provides more accurate and reliable quantification information than traditional isobaric labeling methods (e.g., TMT and iTRAQ) by making use of the entire fragment-ion series instead of only a single reporter ion. The multiplexing capacity of published IPTL implementations is, however, limited to three. Here, we present a selective maleylation-directed isobaric peptide termini labeling (SMD-IPTL) approach for quantitative proteomics of LysC protein digestion. SMD-IPTL extends the multiplexing capacity to 4-plex with the potential for higher levels of multiplexing using commercially available (13)C/(15)N labeled amino acids. SMD-IPTL is achieved in a one-pot reaction in three consecutive steps: (1) selective maleylation at the N-terminus; (2) labeling at the ε-NH(2) group of the C-terminal Lys with isotopically labeled acetyl-alanine; (3) thiol Michael addition of an isotopically labeled acetyl-cysteine at the maleylated N-terminus. The isobarically labeled peptides are fragmented into sets of b- and y-ion clusters upon LC-MS/MS, which convey not only sequence information but also quantitative information for every labeling channel and avoid the issue of ratio distortion observed with reporter-ion-based approaches. We demonstrate the SMD-IPTL approach with a 4-plex labeled sample of bovine serum albumin (BSA) and yeast lysates mixed at different ratios. With the use of SMD-IPTL for labeling and a narrow precursor isolation window of 0.8 Th with an offset of −0.2 Th, accurate ratios were measured across a 10-fold mixing range of BSA in a background of yeast proteome. With the yeast proteins mixed at ratios of 1:5:1:5, BSA was detected at ratios of 0.94:2.46:4.70:9.92 when spiked at 1:2:5:10 ratios with an average standard deviation of peptide ratios of 0.34. American Chemical Society 2020-04-22 2020-06-02 /pmc/articles/PMC7271076/ /pubmed/32319746 http://dx.doi.org/10.1021/acs.analchem.0c01059 Text en Copyright © 2020 American Chemical Society This is an open access article published under a Creative Commons Non-Commercial No Derivative Works (CC-BY-NC-ND) Attribution License (http://pubs.acs.org/page/policy/authorchoice_ccbyncnd_termsofuse.html) , which permits copying and redistribution of the article, and creation of adaptations, all for non-commercial purposes.
spellingShingle Tian, Xiaobo
de Vries, Marcel P.
Visscher, Susan W. J.
Permentier, Hjalmar P.
Bischoff, Rainer
Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title_full Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title_fullStr Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title_full_unstemmed Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title_short Selective Maleylation-Directed Isobaric Peptide Termini Labeling for Accurate Proteome Quantification
title_sort selective maleylation-directed isobaric peptide termini labeling for accurate proteome quantification
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7271076/
https://www.ncbi.nlm.nih.gov/pubmed/32319746
http://dx.doi.org/10.1021/acs.analchem.0c01059
work_keys_str_mv AT tianxiaobo selectivemaleylationdirectedisobaricpeptideterminilabelingforaccurateproteomequantification
AT devriesmarcelp selectivemaleylationdirectedisobaricpeptideterminilabelingforaccurateproteomequantification
AT visschersusanwj selectivemaleylationdirectedisobaricpeptideterminilabelingforaccurateproteomequantification
AT permentierhjalmarp selectivemaleylationdirectedisobaricpeptideterminilabelingforaccurateproteomequantification
AT bischoffrainer selectivemaleylationdirectedisobaricpeptideterminilabelingforaccurateproteomequantification