Cargando…
Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology
Web-core sandwich panels have gained the popularity in various fields, especially aviation and shipbuilding, etc. Penetration welding was considered as an effective process to manufacture such a structure through a T-joint. To ensure the formation quality and mechanical properties of weld, the weldi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273215/ https://www.ncbi.nlm.nih.gov/pubmed/32397323 http://dx.doi.org/10.3390/s20092691 |
_version_ | 1783542355733774336 |
---|---|
author | Wei, Angang Chang, Baohua Meng, Fanyue Du, Dong Han, Zandong |
author_facet | Wei, Angang Chang, Baohua Meng, Fanyue Du, Dong Han, Zandong |
author_sort | Wei, Angang |
collection | PubMed |
description | Web-core sandwich panels have gained the popularity in various fields, especially aviation and shipbuilding, etc. Penetration welding was considered as an effective process to manufacture such a structure through a T-joint. To ensure the formation quality and mechanical properties of weld, the welding torch needs to be aligned with the T-joint position. However, it is difficult to locate the T-joint position (i.e., the position of core panel) because of the shielding of the face panels. This paper investigated the detection of T-joint position from the face panel side in web-core sandwich panels based on eddy current technology. First, we designed an experimental system for the weld position detection of T-joints from the face panel side. The relationships are investigated between the characteristics of the eddy current detection signal and the primary parameters of the detection system (including excitation frequency, coil outer diameter, and lift off distance) and the T-joint (including thickness of the core panel, gap distance, and thickness of the cover panel). Corresponding experiments were carried out with variable primary parameters, and the influence mechanism of the primary parameters on the detection results in terms of sensitivity and dynamic performance was elaborated to set up the theoretical basis for the detection. Finally, weld position detection experiments were carried out on TC4 titanium alloy T-joint specimens with 3 mm-thick face panel and 5 mm-thick core panel. Results showed that the maximum detection error was 0.482 mm, and the average error was 0.234 mm. This paper provided a possible technical solution to the automatic tracking problem for the welding of T-joints in the web-core sandwich panels. |
format | Online Article Text |
id | pubmed-7273215 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72732152020-06-19 Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology Wei, Angang Chang, Baohua Meng, Fanyue Du, Dong Han, Zandong Sensors (Basel) Article Web-core sandwich panels have gained the popularity in various fields, especially aviation and shipbuilding, etc. Penetration welding was considered as an effective process to manufacture such a structure through a T-joint. To ensure the formation quality and mechanical properties of weld, the welding torch needs to be aligned with the T-joint position. However, it is difficult to locate the T-joint position (i.e., the position of core panel) because of the shielding of the face panels. This paper investigated the detection of T-joint position from the face panel side in web-core sandwich panels based on eddy current technology. First, we designed an experimental system for the weld position detection of T-joints from the face panel side. The relationships are investigated between the characteristics of the eddy current detection signal and the primary parameters of the detection system (including excitation frequency, coil outer diameter, and lift off distance) and the T-joint (including thickness of the core panel, gap distance, and thickness of the cover panel). Corresponding experiments were carried out with variable primary parameters, and the influence mechanism of the primary parameters on the detection results in terms of sensitivity and dynamic performance was elaborated to set up the theoretical basis for the detection. Finally, weld position detection experiments were carried out on TC4 titanium alloy T-joint specimens with 3 mm-thick face panel and 5 mm-thick core panel. Results showed that the maximum detection error was 0.482 mm, and the average error was 0.234 mm. This paper provided a possible technical solution to the automatic tracking problem for the welding of T-joints in the web-core sandwich panels. MDPI 2020-05-08 /pmc/articles/PMC7273215/ /pubmed/32397323 http://dx.doi.org/10.3390/s20092691 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wei, Angang Chang, Baohua Meng, Fanyue Du, Dong Han, Zandong Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title | Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title_full | Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title_fullStr | Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title_full_unstemmed | Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title_short | Research on the Weld Position Detection for the T-Joints in Web-Core Sandwich Panels Based on Eddy Current Technology |
title_sort | research on the weld position detection for the t-joints in web-core sandwich panels based on eddy current technology |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273215/ https://www.ncbi.nlm.nih.gov/pubmed/32397323 http://dx.doi.org/10.3390/s20092691 |
work_keys_str_mv | AT weiangang researchontheweldpositiondetectionforthetjointsinwebcoresandwichpanelsbasedoneddycurrenttechnology AT changbaohua researchontheweldpositiondetectionforthetjointsinwebcoresandwichpanelsbasedoneddycurrenttechnology AT mengfanyue researchontheweldpositiondetectionforthetjointsinwebcoresandwichpanelsbasedoneddycurrenttechnology AT dudong researchontheweldpositiondetectionforthetjointsinwebcoresandwichpanelsbasedoneddycurrenttechnology AT hanzandong researchontheweldpositiondetectionforthetjointsinwebcoresandwichpanelsbasedoneddycurrenttechnology |