Cargando…

Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study

OBJECTIVE: Tracheal sounds were used to detect apnea on various occasions. However, ambient noises can contaminate tracheal sounds which result in poor performance of apnea detection. The objective of this paper was to apply the adaptive filtering (AF) algorithm to improve the quality of tracheal so...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Yanan, Liu, Jing, He, Baolin, Zhang, Xiaotong, Yu, Lu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273493/
https://www.ncbi.nlm.nih.gov/pubmed/32596366
http://dx.doi.org/10.1155/2020/7429345
_version_ 1783542417429889024
author Wu, Yanan
Liu, Jing
He, Baolin
Zhang, Xiaotong
Yu, Lu
author_facet Wu, Yanan
Liu, Jing
He, Baolin
Zhang, Xiaotong
Yu, Lu
author_sort Wu, Yanan
collection PubMed
description OBJECTIVE: Tracheal sounds were used to detect apnea on various occasions. However, ambient noises can contaminate tracheal sounds which result in poor performance of apnea detection. The objective of this paper was to apply the adaptive filtering (AF) algorithm to improve the quality of tracheal sounds and examine the accuracy of the apnea detection algorithm using tracheal sounds after AF. METHOD: Tracheal sounds were acquired using a primary microphone encased in a plastic bell, and the ambient noises were collected using a reference microphone resting outside the plastic bell in quiet and noisy environments, respectively. Simultaneously, the flow pressure signals and thoracic and abdominal movement were obtained as the standard signals to determine apnea events. Then, the normalized least mean square (NLMS) AF algorithm was applied to the tracheal sounds mixed with noises. Finally, the algorithm of apnea detection was used to the tracheal sounds with AF and the tracheal sounds without AF. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Cohen's kappa coefficient of apnea detection were calculated. RESULTS: Forty-six healthy subjects, aged 18-35 years and with BMI < 21.4, were included in the study. The apnea detection performance using tracheal sounds was as follows: in the quiet environment, the tracheal sounds without AF detected apnea with 97.2% sensitivity, 99.9% specificity, 99.8% PPV, 99.4% NPV, 99.5% accuracy, and 0.982 kappa coefficient. The tracheal sounds with AF detected apnea with 98.2% sensitivity, 99.9% specificity, 99.4% PPV, 99.6% NPV, 99.6% accuracy, and 0.985 kappa coefficient. While in the noisy environment, the tracheal sounds without AF detected apnea with 81.1% sensitivity, 96.9% specificity, 85.1% PPV, 96% NPV, 94.2% accuracy, and 0.795 kappa coefficient and the tracheal sounds with AF detected apnea with 91.5% sensitivity, 97.4% specificity, 88.4% PPV, 98.2% NPV, 96.4% accuracy, and 0.877 kappa coefficient. CONCLUSION: The performance of apnea detection using tracheal sounds with the NLMS AF algorithm in the noisy environment proved to be accurate and reliable. The AF technology could be applied to the respiratory monitoring using tracheal sounds.
format Online
Article
Text
id pubmed-7273493
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-72734932020-06-27 Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study Wu, Yanan Liu, Jing He, Baolin Zhang, Xiaotong Yu, Lu Biomed Res Int Research Article OBJECTIVE: Tracheal sounds were used to detect apnea on various occasions. However, ambient noises can contaminate tracheal sounds which result in poor performance of apnea detection. The objective of this paper was to apply the adaptive filtering (AF) algorithm to improve the quality of tracheal sounds and examine the accuracy of the apnea detection algorithm using tracheal sounds after AF. METHOD: Tracheal sounds were acquired using a primary microphone encased in a plastic bell, and the ambient noises were collected using a reference microphone resting outside the plastic bell in quiet and noisy environments, respectively. Simultaneously, the flow pressure signals and thoracic and abdominal movement were obtained as the standard signals to determine apnea events. Then, the normalized least mean square (NLMS) AF algorithm was applied to the tracheal sounds mixed with noises. Finally, the algorithm of apnea detection was used to the tracheal sounds with AF and the tracheal sounds without AF. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Cohen's kappa coefficient of apnea detection were calculated. RESULTS: Forty-six healthy subjects, aged 18-35 years and with BMI < 21.4, were included in the study. The apnea detection performance using tracheal sounds was as follows: in the quiet environment, the tracheal sounds without AF detected apnea with 97.2% sensitivity, 99.9% specificity, 99.8% PPV, 99.4% NPV, 99.5% accuracy, and 0.982 kappa coefficient. The tracheal sounds with AF detected apnea with 98.2% sensitivity, 99.9% specificity, 99.4% PPV, 99.6% NPV, 99.6% accuracy, and 0.985 kappa coefficient. While in the noisy environment, the tracheal sounds without AF detected apnea with 81.1% sensitivity, 96.9% specificity, 85.1% PPV, 96% NPV, 94.2% accuracy, and 0.795 kappa coefficient and the tracheal sounds with AF detected apnea with 91.5% sensitivity, 97.4% specificity, 88.4% PPV, 98.2% NPV, 96.4% accuracy, and 0.877 kappa coefficient. CONCLUSION: The performance of apnea detection using tracheal sounds with the NLMS AF algorithm in the noisy environment proved to be accurate and reliable. The AF technology could be applied to the respiratory monitoring using tracheal sounds. Hindawi 2020-05-21 /pmc/articles/PMC7273493/ /pubmed/32596366 http://dx.doi.org/10.1155/2020/7429345 Text en Copyright © 2020 Yanan Wu et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wu, Yanan
Liu, Jing
He, Baolin
Zhang, Xiaotong
Yu, Lu
Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title_full Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title_fullStr Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title_full_unstemmed Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title_short Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study
title_sort adaptive filtering improved apnea detection performance using tracheal sounds in noisy environment: a simulation study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273493/
https://www.ncbi.nlm.nih.gov/pubmed/32596366
http://dx.doi.org/10.1155/2020/7429345
work_keys_str_mv AT wuyanan adaptivefilteringimprovedapneadetectionperformanceusingtrachealsoundsinnoisyenvironmentasimulationstudy
AT liujing adaptivefilteringimprovedapneadetectionperformanceusingtrachealsoundsinnoisyenvironmentasimulationstudy
AT hebaolin adaptivefilteringimprovedapneadetectionperformanceusingtrachealsoundsinnoisyenvironmentasimulationstudy
AT zhangxiaotong adaptivefilteringimprovedapneadetectionperformanceusingtrachealsoundsinnoisyenvironmentasimulationstudy
AT yulu adaptivefilteringimprovedapneadetectionperformanceusingtrachealsoundsinnoisyenvironmentasimulationstudy