Cargando…

High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections

AIMS AND OBJECTIVES: A major obstacle for the treatment of prosthetic joint infections (PJIs) is the identification of the organism causing it. While the diagnostic criteria ruling PJIs in or out have become ever more accurate, detecting the causative pathogen(s) still relies mostly on conventional...

Descripción completa

Detalles Bibliográficos
Autores principales: Suren, Christian, Feihl, Susanne, Cabric, Sabrina, Banke, Ingo, Haller, Bernhard, Trampuz, Andrej, von Eisenhart-Rothe, Rüdiger, Prodinger, Peter Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273794/
http://dx.doi.org/10.1177/2325967120S00303
_version_ 1783542476971180032
author Suren, Christian
Feihl, Susanne
Cabric, Sabrina
Banke, Ingo
Haller, Bernhard
Trampuz, Andrej
von Eisenhart-Rothe, Rüdiger
Prodinger, Peter Michael
author_facet Suren, Christian
Feihl, Susanne
Cabric, Sabrina
Banke, Ingo
Haller, Bernhard
Trampuz, Andrej
von Eisenhart-Rothe, Rüdiger
Prodinger, Peter Michael
author_sort Suren, Christian
collection PubMed
description AIMS AND OBJECTIVES: A major obstacle for the treatment of prosthetic joint infections (PJIs) is the identification of the organism causing it. While the diagnostic criteria ruling PJIs in or out have become ever more accurate, detecting the causative pathogen(s) still relies mostly on conventional culture. The aim of this study was to evaluate the diagnostic potential of a second generation multiplex PCR assay (Unyvero ITI G2, Curetis AG, Holzgerlingen, Germany) used on synovial fluid specimens. MATERIALS AND METHODS: Prospectively collected frozen joint fluid specimens from 26 patients undergoing arthroplasty revision surgery of the hip or knee for any reason were tested as per the manufacturer’s protocol. The sensitivity and specificity were calculated using the Chi-squared-test and a combination of the serum CRP level, leukocyte count, erythrocyte sedimentation rate, joint fluid culture, tissue biopsy culture, and tissue biopsy histology served as gold standard. RESULTS: Of the 26 cases included in the study, 15 were infected and 11 aseptic. Conventional joint fluid culture showed a sensitivity 0.67 and a specificity of 0.91. Joint fluid multiplex PCR yielded a sensitivity of 0.8 and a specificity of 1.0. CONCLUSION: This is the first study to assess the second generation Unyvero ITI cartridge on joint fluid aspirate for the detection of prosthetic joint infection. In our setting, the method achieved a higher diagnostic accuracy than conventional culture. We conclude that, to improve pathogen detection before revision surgery, this method represents a valuable tool.
format Online
Article
Text
id pubmed-7273794
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-72737942020-06-15 High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections Suren, Christian Feihl, Susanne Cabric, Sabrina Banke, Ingo Haller, Bernhard Trampuz, Andrej von Eisenhart-Rothe, Rüdiger Prodinger, Peter Michael Orthop J Sports Med Article AIMS AND OBJECTIVES: A major obstacle for the treatment of prosthetic joint infections (PJIs) is the identification of the organism causing it. While the diagnostic criteria ruling PJIs in or out have become ever more accurate, detecting the causative pathogen(s) still relies mostly on conventional culture. The aim of this study was to evaluate the diagnostic potential of a second generation multiplex PCR assay (Unyvero ITI G2, Curetis AG, Holzgerlingen, Germany) used on synovial fluid specimens. MATERIALS AND METHODS: Prospectively collected frozen joint fluid specimens from 26 patients undergoing arthroplasty revision surgery of the hip or knee for any reason were tested as per the manufacturer’s protocol. The sensitivity and specificity were calculated using the Chi-squared-test and a combination of the serum CRP level, leukocyte count, erythrocyte sedimentation rate, joint fluid culture, tissue biopsy culture, and tissue biopsy histology served as gold standard. RESULTS: Of the 26 cases included in the study, 15 were infected and 11 aseptic. Conventional joint fluid culture showed a sensitivity 0.67 and a specificity of 0.91. Joint fluid multiplex PCR yielded a sensitivity of 0.8 and a specificity of 1.0. CONCLUSION: This is the first study to assess the second generation Unyvero ITI cartridge on joint fluid aspirate for the detection of prosthetic joint infection. In our setting, the method achieved a higher diagnostic accuracy than conventional culture. We conclude that, to improve pathogen detection before revision surgery, this method represents a valuable tool. SAGE Publications 2020-05-29 /pmc/articles/PMC7273794/ http://dx.doi.org/10.1177/2325967120S00303 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Suren, Christian
Feihl, Susanne
Cabric, Sabrina
Banke, Ingo
Haller, Bernhard
Trampuz, Andrej
von Eisenhart-Rothe, Rüdiger
Prodinger, Peter Michael
High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title_full High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title_fullStr High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title_full_unstemmed High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title_short High Accuracy of Second Generation Unyvero ITI Automated Multiplex PCR Analysis of Joint Fluid Aspirate in Low-Grade Prosthetic Hip and Knee Joint Infections
title_sort high accuracy of second generation unyvero iti automated multiplex pcr analysis of joint fluid aspirate in low-grade prosthetic hip and knee joint infections
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7273794/
http://dx.doi.org/10.1177/2325967120S00303
work_keys_str_mv AT surenchristian highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT feihlsusanne highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT cabricsabrina highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT bankeingo highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT hallerbernhard highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT trampuzandrej highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT voneisenhartrotherudiger highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections
AT prodingerpetermichael highaccuracyofsecondgenerationunyveroitiautomatedmultiplexpcranalysisofjointfluidaspirateinlowgradeprosthetichipandkneejointinfections