Cargando…

Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study

Objectives  The integration of computer-aided design and manufacturing technologies in diagnosis, treatment planning, and fabrication of prosthetic restoration is changing the way in which prosthodontic treatment is provided to patients. The aim of this study was to compare the accuracy of three-dim...

Descripción completa

Detalles Bibliográficos
Autores principales: Aly, Passent, Mohsen, Cherif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Private Ltd. 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7274830/
https://www.ncbi.nlm.nih.gov/pubmed/32311750
http://dx.doi.org/10.1055/s-0040-1705243
_version_ 1783542670299234304
author Aly, Passent
Mohsen, Cherif
author_facet Aly, Passent
Mohsen, Cherif
author_sort Aly, Passent
collection PubMed
description Objectives  The integration of computer-aided design and manufacturing technologies in diagnosis, treatment planning, and fabrication of prosthetic restoration is changing the way in which prosthodontic treatment is provided to patients. The aim of this study was to compare the accuracy of three-dimensional (3D) printed casts produced from the intraoral scanner using stereolithographic (SLA) 3D printing technique, their digital replicas, and conventional stone casts. Materials and Methods  In this in vitro study, a typodont of maxillary and mandibular arches with full dentate ivory teeth was used as a reference cast. The typodont was digitized using Trios 3Shape intraoral scanner to create digital casts. The digital files were converted into 3D printed physical casts using a prototyping machine that utilizes the stereolithography printing technology and photocurable polymer as printing material. Linear measurements (mesiodistal and occlusocervical) and interarch measurements (intercanine and intermolar) were made for digital and prototyped models and were compared with the original stone casts. The reference teeth were canines, first premolars and second premolars in the maxillary and mandibular arches on the right and left sides. The measurements on printed and conventional casts were done by digital caliper while on digital casts; Geomagic Qualify software was used. Statistical Analysis  One-way analysis of variance (ANOVA) was used to compare measurements among groups. Results  Digital casts showed significantly higher error than the other two groups in all linear and interarch measurements. The mean errors of the digital cast in occlusocervical (OC) and mesiodistal (MD) measurements (0.016 and 0.006, respectively) were higher compared with those in the other two groups (OC, 0.004 and 0.007 and MD, 0.003 and 0.005 [ p < 0.0001 and p = 0.02, respectively]). Also, digital mean error in intermolar width (IMW) and intercanine width (ICW) (0.142 and 0.113, respectively) were greater than the other two groups (IMW, 0.019 and 0.008 and ICW, 0.021 and 0.011 [ p < 0.0001]). However, the errors were within the acceptable clinical range. Conclusion  The 3D printed casts may be considered as a substitute for stone casts with clinically acceptable accuracy that can be used in diagnosis, treatment planning, and fabrication of prosthetic restorations.
format Online
Article
Text
id pubmed-7274830
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical and Scientific Publishers Private Ltd.
record_format MEDLINE/PubMed
spelling pubmed-72748302020-06-10 Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study Aly, Passent Mohsen, Cherif Eur J Dent Objectives  The integration of computer-aided design and manufacturing technologies in diagnosis, treatment planning, and fabrication of prosthetic restoration is changing the way in which prosthodontic treatment is provided to patients. The aim of this study was to compare the accuracy of three-dimensional (3D) printed casts produced from the intraoral scanner using stereolithographic (SLA) 3D printing technique, their digital replicas, and conventional stone casts. Materials and Methods  In this in vitro study, a typodont of maxillary and mandibular arches with full dentate ivory teeth was used as a reference cast. The typodont was digitized using Trios 3Shape intraoral scanner to create digital casts. The digital files were converted into 3D printed physical casts using a prototyping machine that utilizes the stereolithography printing technology and photocurable polymer as printing material. Linear measurements (mesiodistal and occlusocervical) and interarch measurements (intercanine and intermolar) were made for digital and prototyped models and were compared with the original stone casts. The reference teeth were canines, first premolars and second premolars in the maxillary and mandibular arches on the right and left sides. The measurements on printed and conventional casts were done by digital caliper while on digital casts; Geomagic Qualify software was used. Statistical Analysis  One-way analysis of variance (ANOVA) was used to compare measurements among groups. Results  Digital casts showed significantly higher error than the other two groups in all linear and interarch measurements. The mean errors of the digital cast in occlusocervical (OC) and mesiodistal (MD) measurements (0.016 and 0.006, respectively) were higher compared with those in the other two groups (OC, 0.004 and 0.007 and MD, 0.003 and 0.005 [ p < 0.0001 and p = 0.02, respectively]). Also, digital mean error in intermolar width (IMW) and intercanine width (ICW) (0.142 and 0.113, respectively) were greater than the other two groups (IMW, 0.019 and 0.008 and ICW, 0.021 and 0.011 [ p < 0.0001]). However, the errors were within the acceptable clinical range. Conclusion  The 3D printed casts may be considered as a substitute for stone casts with clinically acceptable accuracy that can be used in diagnosis, treatment planning, and fabrication of prosthetic restorations. Thieme Medical and Scientific Publishers Private Ltd. 2020-05 2020-04-20 /pmc/articles/PMC7274830/ /pubmed/32311750 http://dx.doi.org/10.1055/s-0040-1705243 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Aly, Passent
Mohsen, Cherif
Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title_full Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title_fullStr Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title_full_unstemmed Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title_short Comparison of the Accuracy of Three-Dimensional Printed Casts, Digital, and Conventional Casts: An In Vitro Study
title_sort comparison of the accuracy of three-dimensional printed casts, digital, and conventional casts: an in vitro study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7274830/
https://www.ncbi.nlm.nih.gov/pubmed/32311750
http://dx.doi.org/10.1055/s-0040-1705243
work_keys_str_mv AT alypassent comparisonoftheaccuracyofthreedimensionalprintedcastsdigitalandconventionalcastsaninvitrostudy
AT mohsencherif comparisonoftheaccuracyofthreedimensionalprintedcastsdigitalandconventionalcastsaninvitrostudy