Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices
PURPOSE: The purpose of this study was to compare the efficacy and safety of cataract surgery by the phacoemulsification technique with and without the use of ophthalmic viscosurgical devices (OVDs). SETTING: This study was conducted at a tertiary eye care center in a rural area of Central India. DE...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276164/ https://www.ncbi.nlm.nih.gov/pubmed/32549724 http://dx.doi.org/10.4103/meajo.MEAJO_140_19 |
_version_ | 1783542909050552320 |
---|---|
author | Joshi, Rajesh Subhash Naik, Sanoja Rangnath |
author_facet | Joshi, Rajesh Subhash Naik, Sanoja Rangnath |
author_sort | Joshi, Rajesh Subhash |
collection | PubMed |
description | PURPOSE: The purpose of this study was to compare the efficacy and safety of cataract surgery by the phacoemulsification technique with and without the use of ophthalmic viscosurgical devices (OVDs). SETTING: This study was conducted at a tertiary eye care center in a rural area of Central India. DESIGN: This was a prospective, randomized, observational study. METHODS: In this study, 220 patients underwent phacoemulsification for cataract surgery with OVDs (OVD group) or without OVDs (BSS group) (n = 110 in each group). Patients with operable, nuclear Grade 2–4 cataracts were included in the study. The study was conducted from June 2017 to September 2018. The frequency of intraoperative complications, surgical time, and ease of the surgical procedure (easy, difficult, or very difficult) were recorded. RESULTS: There was no statistically significant difference in the nuclear opalescence, axial length, and intraocular lens (IOL) power between the two groups. Capsulorhexis extension was seen in two eyes in the OVD group and none of the eyes in the BSS group. The problems that occurred during IOL implantation included flip (OVD group, 2; BSS group, 1), haptic breakage (OVD group, 1; BSS group, 1), sulcus implantation (OVD group, 0; BSS group, 2), and stuck haptic (OVD group, 1; BSS group, 3). The total surgical time was almost equal in the two groups (OVD group, 9.2 min ± 3; BSS group, 9.5 min ± 3.5; P = 0.521). None of the patients had iris trauma or posterior capsular rupture. CONCLUSIONS: OVD-less phacoemulsification surgery is a safe and effective technique for treating age-related cataracts that requires no additional instrumentation and saves the cost of the OVD. |
format | Online Article Text |
id | pubmed-7276164 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-72761642020-06-16 Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices Joshi, Rajesh Subhash Naik, Sanoja Rangnath Middle East Afr J Ophthalmol Original Article PURPOSE: The purpose of this study was to compare the efficacy and safety of cataract surgery by the phacoemulsification technique with and without the use of ophthalmic viscosurgical devices (OVDs). SETTING: This study was conducted at a tertiary eye care center in a rural area of Central India. DESIGN: This was a prospective, randomized, observational study. METHODS: In this study, 220 patients underwent phacoemulsification for cataract surgery with OVDs (OVD group) or without OVDs (BSS group) (n = 110 in each group). Patients with operable, nuclear Grade 2–4 cataracts were included in the study. The study was conducted from June 2017 to September 2018. The frequency of intraoperative complications, surgical time, and ease of the surgical procedure (easy, difficult, or very difficult) were recorded. RESULTS: There was no statistically significant difference in the nuclear opalescence, axial length, and intraocular lens (IOL) power between the two groups. Capsulorhexis extension was seen in two eyes in the OVD group and none of the eyes in the BSS group. The problems that occurred during IOL implantation included flip (OVD group, 2; BSS group, 1), haptic breakage (OVD group, 1; BSS group, 1), sulcus implantation (OVD group, 0; BSS group, 2), and stuck haptic (OVD group, 1; BSS group, 3). The total surgical time was almost equal in the two groups (OVD group, 9.2 min ± 3; BSS group, 9.5 min ± 3.5; P = 0.521). None of the patients had iris trauma or posterior capsular rupture. CONCLUSIONS: OVD-less phacoemulsification surgery is a safe and effective technique for treating age-related cataracts that requires no additional instrumentation and saves the cost of the OVD. Wolters Kluwer - Medknow 2020-04-29 /pmc/articles/PMC7276164/ /pubmed/32549724 http://dx.doi.org/10.4103/meajo.MEAJO_140_19 Text en Copyright: © 2020 Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Joshi, Rajesh Subhash Naik, Sanoja Rangnath Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title | Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title_full | Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title_fullStr | Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title_full_unstemmed | Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title_short | Intraoperative Evaluation of Phacoemulsification Cataract Surgery with and without the Use of Ophthalmic Viscosurgical Devices |
title_sort | intraoperative evaluation of phacoemulsification cataract surgery with and without the use of ophthalmic viscosurgical devices |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276164/ https://www.ncbi.nlm.nih.gov/pubmed/32549724 http://dx.doi.org/10.4103/meajo.MEAJO_140_19 |
work_keys_str_mv | AT joshirajeshsubhash intraoperativeevaluationofphacoemulsificationcataractsurgerywithandwithouttheuseofophthalmicviscosurgicaldevices AT naiksanojarangnath intraoperativeevaluationofphacoemulsificationcataractsurgerywithandwithouttheuseofophthalmicviscosurgicaldevices |