Cargando…

Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye

PURPOSE: The aim of this study is to investigate the effects of electromagnetic waves (EMWs) emitted by a mobile phone on the intraocular pressure (IOP) in the eyeball. METHODS: This quasi-experimental study was conducted on 166 eyes from 83 individuals in the 40–70 age range who referred to “Khatam...

Descripción completa

Detalles Bibliográficos
Autores principales: Shokoohi-Rad, Saeed, Ansari, Mohammad-Rez, Sabzi, Fatemeh, Saffari, Rahim, Rajaei, Parisa, Karimi, Farshid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276173/
https://www.ncbi.nlm.nih.gov/pubmed/32549718
http://dx.doi.org/10.4103/meajo.MEAJO_20_19
_version_ 1783542911176015872
author Shokoohi-Rad, Saeed
Ansari, Mohammad-Rez
Sabzi, Fatemeh
Saffari, Rahim
Rajaei, Parisa
Karimi, Farshid
author_facet Shokoohi-Rad, Saeed
Ansari, Mohammad-Rez
Sabzi, Fatemeh
Saffari, Rahim
Rajaei, Parisa
Karimi, Farshid
author_sort Shokoohi-Rad, Saeed
collection PubMed
description PURPOSE: The aim of this study is to investigate the effects of electromagnetic waves (EMWs) emitted by a mobile phone on the intraocular pressure (IOP) in the eyeball. METHODS: This quasi-experimental study was conducted on 166 eyes from 83 individuals in the 40–70 age range who referred to “Khatam-al-Anbia Hospital, Mashhad, Iran” in 2016. There were two groups of participants, and the first one consisted of 41 participants who had normal eyes, whereas the second one comprised 42 participants who suffered from open-angle glaucoma disease. The IOP in both groups was measured and recorded by a specialist before and after talking 5 min on the cellphone with the help of the Goldman method. Statistical analysis such as paired t-test and analysis of variance was performed and all tests are statistically significant at (P < 0.05). For this purpose, the SPSS software (version 16) was applied. RESULTS: IOP in the glaucoma eye (42 eyes) ipsilateral to mobile phone before and after the intervention was 18.64 ± 6.7 and 23.53 ± 6.3, respectively (P < 0.001). However, IOP in the control group (41 eyes) ipsilateral to mobile phone before and after the intervention was 12.95 ± 3.5 and 13.39 ± 2.8, respectively (P = 0.063). IOP change in the opposite glaucomatous eye to mobile phone in glaucoma group (39 eyes) and normal group (44 eyes) was not significantly different before and after the phone call (P = 0.065 and P = 0.85, respectively). CONCLUSION: We found that the acute effects of EMWs emitted from the mobile phones can significantly increase the IOP in glaucoma eye, while such changes were not observed in normal eyes.
format Online
Article
Text
id pubmed-7276173
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-72761732020-06-16 Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye Shokoohi-Rad, Saeed Ansari, Mohammad-Rez Sabzi, Fatemeh Saffari, Rahim Rajaei, Parisa Karimi, Farshid Middle East Afr J Ophthalmol Original Article PURPOSE: The aim of this study is to investigate the effects of electromagnetic waves (EMWs) emitted by a mobile phone on the intraocular pressure (IOP) in the eyeball. METHODS: This quasi-experimental study was conducted on 166 eyes from 83 individuals in the 40–70 age range who referred to “Khatam-al-Anbia Hospital, Mashhad, Iran” in 2016. There were two groups of participants, and the first one consisted of 41 participants who had normal eyes, whereas the second one comprised 42 participants who suffered from open-angle glaucoma disease. The IOP in both groups was measured and recorded by a specialist before and after talking 5 min on the cellphone with the help of the Goldman method. Statistical analysis such as paired t-test and analysis of variance was performed and all tests are statistically significant at (P < 0.05). For this purpose, the SPSS software (version 16) was applied. RESULTS: IOP in the glaucoma eye (42 eyes) ipsilateral to mobile phone before and after the intervention was 18.64 ± 6.7 and 23.53 ± 6.3, respectively (P < 0.001). However, IOP in the control group (41 eyes) ipsilateral to mobile phone before and after the intervention was 12.95 ± 3.5 and 13.39 ± 2.8, respectively (P = 0.063). IOP change in the opposite glaucomatous eye to mobile phone in glaucoma group (39 eyes) and normal group (44 eyes) was not significantly different before and after the phone call (P = 0.065 and P = 0.85, respectively). CONCLUSION: We found that the acute effects of EMWs emitted from the mobile phones can significantly increase the IOP in glaucoma eye, while such changes were not observed in normal eyes. Wolters Kluwer - Medknow 2020-04-29 /pmc/articles/PMC7276173/ /pubmed/32549718 http://dx.doi.org/10.4103/meajo.MEAJO_20_19 Text en Copyright: © 2020 Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Shokoohi-Rad, Saeed
Ansari, Mohammad-Rez
Sabzi, Fatemeh
Saffari, Rahim
Rajaei, Parisa
Karimi, Farshid
Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title_full Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title_fullStr Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title_full_unstemmed Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title_short Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye
title_sort comparison of intraocular pressure changes due to exposure to mobile phone electromagnetics radiations in normal and glaucoma eye
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276173/
https://www.ncbi.nlm.nih.gov/pubmed/32549718
http://dx.doi.org/10.4103/meajo.MEAJO_20_19
work_keys_str_mv AT shokoohiradsaeed comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye
AT ansarimohammadrez comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye
AT sabzifatemeh comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye
AT saffarirahim comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye
AT rajaeiparisa comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye
AT karimifarshid comparisonofintraocularpressurechangesduetoexposuretomobilephoneelectromagneticsradiationsinnormalandglaucomaeye