Cargando…

Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population

PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valv...

Descripción completa

Detalles Bibliográficos
Autores principales: Osman, Essam A., Alkheraiji, Norah F., Abouammoh, Mohammad A., Mousa, Ahmed, Al-Obeidan, Saleh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276174/
https://www.ncbi.nlm.nih.gov/pubmed/32549723
http://dx.doi.org/10.4103/meajo.MEAJO_249_19
_version_ 1783542911410896896
author Osman, Essam A.
Alkheraiji, Norah F.
Abouammoh, Mohammad A.
Mousa, Ahmed
Al-Obeidan, Saleh
author_facet Osman, Essam A.
Alkheraiji, Norah F.
Abouammoh, Mohammad A.
Mousa, Ahmed
Al-Obeidan, Saleh
author_sort Osman, Essam A.
collection PubMed
description PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valve implant was done in a tertiary care center in Riyadh, Saudi Arabia, between January 2014 and December 2016. Complete success was defined as intraocular pressure (IOP) ≤21 mmHg without medication after a minimum follow-up of 6 months. RESULTS: Eighty-three patients (117 eyes) with intractable glaucoma were evaluated. After a mean follow-up duration of 20.8 ± 3.1 (12–24) months, the overall success rate was achieved in 104 eyes (88.9%). Thirty-six eyes (30.8%) had a complete success rate, whereas 68 eyes (58.1%) had a qualified success rate. Thirteen eyes (11.1%) failed to achieve controlled IOP. The postoperative probability to fail was found to be increasing with time from 0.9% (0.9) in the 1(st) month to 11.1% (9.9) after 1 year. Complications included a hypertensive phase in 25 eyes (21.4%), encapsulation in 10 eyes (8.5%), hyphema in 7 eyes (6%), hypotony in 2 eyes (1.7%), and blood clots in the implanted tube in 2 eyes (1.7%). The presence of hyphema, scleral patch, and coronary heart diseases was found to increase the risk of failure after Ahmed valve implantation (P = 0.006, 0.040, and 0.014, respectively). CONCLUSIONS: Ahmed glaucoma valve implant was safe and effective in treating cases of intractable glaucoma.
format Online
Article
Text
id pubmed-7276174
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-72761742020-06-16 Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population Osman, Essam A. Alkheraiji, Norah F. Abouammoh, Mohammad A. Mousa, Ahmed Al-Obeidan, Saleh Middle East Afr J Ophthalmol Original Article PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valve implant was done in a tertiary care center in Riyadh, Saudi Arabia, between January 2014 and December 2016. Complete success was defined as intraocular pressure (IOP) ≤21 mmHg without medication after a minimum follow-up of 6 months. RESULTS: Eighty-three patients (117 eyes) with intractable glaucoma were evaluated. After a mean follow-up duration of 20.8 ± 3.1 (12–24) months, the overall success rate was achieved in 104 eyes (88.9%). Thirty-six eyes (30.8%) had a complete success rate, whereas 68 eyes (58.1%) had a qualified success rate. Thirteen eyes (11.1%) failed to achieve controlled IOP. The postoperative probability to fail was found to be increasing with time from 0.9% (0.9) in the 1(st) month to 11.1% (9.9) after 1 year. Complications included a hypertensive phase in 25 eyes (21.4%), encapsulation in 10 eyes (8.5%), hyphema in 7 eyes (6%), hypotony in 2 eyes (1.7%), and blood clots in the implanted tube in 2 eyes (1.7%). The presence of hyphema, scleral patch, and coronary heart diseases was found to increase the risk of failure after Ahmed valve implantation (P = 0.006, 0.040, and 0.014, respectively). CONCLUSIONS: Ahmed glaucoma valve implant was safe and effective in treating cases of intractable glaucoma. Wolters Kluwer - Medknow 2020-04-29 /pmc/articles/PMC7276174/ /pubmed/32549723 http://dx.doi.org/10.4103/meajo.MEAJO_249_19 Text en Copyright: © 2020 Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Osman, Essam A.
Alkheraiji, Norah F.
Abouammoh, Mohammad A.
Mousa, Ahmed
Al-Obeidan, Saleh
Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title_full Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title_fullStr Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title_full_unstemmed Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title_short Safety and Efficacy of Ahmed Valve on Intractable Glaucoma in Saudi Population
title_sort safety and efficacy of ahmed valve on intractable glaucoma in saudi population
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276174/
https://www.ncbi.nlm.nih.gov/pubmed/32549723
http://dx.doi.org/10.4103/meajo.MEAJO_249_19
work_keys_str_mv AT osmanessama safetyandefficacyofahmedvalveonintractableglaucomainsaudipopulation
AT alkheraijinorahf safetyandefficacyofahmedvalveonintractableglaucomainsaudipopulation
AT abouammohmohammada safetyandefficacyofahmedvalveonintractableglaucomainsaudipopulation
AT mousaahmed safetyandefficacyofahmedvalveonintractableglaucomainsaudipopulation
AT alobeidansaleh safetyandefficacyofahmedvalveonintractableglaucomainsaudipopulation