Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes

PURPOSE: There are limited clinical data on scanning-beam proton therapy (SPT) in treating locally advanced lung cancer, as most published studies have used passive-scatter technology. There is increasing interest in whether the dosimetric advantages of SPT compared with photon therapy can translate...

Descripción completa

Detalles Bibliográficos
Autores principales: Zou, Zhenwei, Bowen, Stephen R., Thomas, Hannah M.T., Sasidharan, Balu Krishna, Rengan, Ramesh, Zeng, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276696/
https://www.ncbi.nlm.nih.gov/pubmed/32529138
http://dx.doi.org/10.1016/j.adro.2020.03.001
_version_ 1783543004016934912
author Zou, Zhenwei
Bowen, Stephen R.
Thomas, Hannah M.T.
Sasidharan, Balu Krishna
Rengan, Ramesh
Zeng, Jing
author_facet Zou, Zhenwei
Bowen, Stephen R.
Thomas, Hannah M.T.
Sasidharan, Balu Krishna
Rengan, Ramesh
Zeng, Jing
author_sort Zou, Zhenwei
collection PubMed
description PURPOSE: There are limited clinical data on scanning-beam proton therapy (SPT) in treating locally advanced lung cancer, as most published studies have used passive-scatter technology. There is increasing interest in whether the dosimetric advantages of SPT compared with photon therapy can translate into superior clinical outcomes. We present our experience of SPT and photon intensity modulated radiation therapy (IMRT) with clinical dosimetry and outcomes in patients with stage III lung cancer. METHODS AND MATERIALS: Patients with stage III lung cancer treated at our center between 2013 and May 2018 were identified in compliance with our institutional review board (64 patients = 34 SPT + 30 IMRT). Most proton patients were treated with pencil beam scanning (28 of 34), and 6 of 34 were treated with uniform scanning. Fisher exact test, χ(2) test, and Mann-Whitney test were used to compare groups. All tests were 2-sided. RESULTS: Patient characteristics were similar between the IMRT and SPT patients, except for worse lung function in the IMRT group. Mean dose to lung, heart, and esophagus was lower in the SPT group, with most benefit in the low-dose region (lungs, 9.7 Gy vs 15.7 Gy for SPT vs IMRT, respectively [P = .004]; heart, 7 Gy vs 14 Gy [P = .001]; esophagus, 28.2 Gy vs 30.9 Gy [P = .023]). Esophagitis and dermatitis grades were not different between the 2 groups. Grade 2+ pneumonitis was 21% in the SPT group and 40% in the IMRT group (P = .107). Changes in blood counts were not different between the 2 groups. Overall survival and progression-free survival were not different between SPT and IMRT (median overall survival, 41.6 vs 30.7 months, respectively [P = .52]; median progression-free survival, 19.5 vs 14.6 months [P = .50]). CONCLUSIONS: We report our experience with SPT and IMRT in stage III lung cancer. Our cohort of patients treated with SPT had lower doses to normal organs (lungs, heart, esophagus) than our IMRT cohort. There was no statistically significant difference in toxicity rates or survival, although there may have been a trend toward lower rates of pneumonitis.
format Online
Article
Text
id pubmed-7276696
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72766962020-06-10 Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes Zou, Zhenwei Bowen, Stephen R. Thomas, Hannah M.T. Sasidharan, Balu Krishna Rengan, Ramesh Zeng, Jing Adv Radiat Oncol Thoracic Cancer PURPOSE: There are limited clinical data on scanning-beam proton therapy (SPT) in treating locally advanced lung cancer, as most published studies have used passive-scatter technology. There is increasing interest in whether the dosimetric advantages of SPT compared with photon therapy can translate into superior clinical outcomes. We present our experience of SPT and photon intensity modulated radiation therapy (IMRT) with clinical dosimetry and outcomes in patients with stage III lung cancer. METHODS AND MATERIALS: Patients with stage III lung cancer treated at our center between 2013 and May 2018 were identified in compliance with our institutional review board (64 patients = 34 SPT + 30 IMRT). Most proton patients were treated with pencil beam scanning (28 of 34), and 6 of 34 were treated with uniform scanning. Fisher exact test, χ(2) test, and Mann-Whitney test were used to compare groups. All tests were 2-sided. RESULTS: Patient characteristics were similar between the IMRT and SPT patients, except for worse lung function in the IMRT group. Mean dose to lung, heart, and esophagus was lower in the SPT group, with most benefit in the low-dose region (lungs, 9.7 Gy vs 15.7 Gy for SPT vs IMRT, respectively [P = .004]; heart, 7 Gy vs 14 Gy [P = .001]; esophagus, 28.2 Gy vs 30.9 Gy [P = .023]). Esophagitis and dermatitis grades were not different between the 2 groups. Grade 2+ pneumonitis was 21% in the SPT group and 40% in the IMRT group (P = .107). Changes in blood counts were not different between the 2 groups. Overall survival and progression-free survival were not different between SPT and IMRT (median overall survival, 41.6 vs 30.7 months, respectively [P = .52]; median progression-free survival, 19.5 vs 14.6 months [P = .50]). CONCLUSIONS: We report our experience with SPT and IMRT in stage III lung cancer. Our cohort of patients treated with SPT had lower doses to normal organs (lungs, heart, esophagus) than our IMRT cohort. There was no statistically significant difference in toxicity rates or survival, although there may have been a trend toward lower rates of pneumonitis. Elsevier 2020-03-20 /pmc/articles/PMC7276696/ /pubmed/32529138 http://dx.doi.org/10.1016/j.adro.2020.03.001 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Thoracic Cancer
Zou, Zhenwei
Bowen, Stephen R.
Thomas, Hannah M.T.
Sasidharan, Balu Krishna
Rengan, Ramesh
Zeng, Jing
Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title_full Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title_fullStr Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title_full_unstemmed Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title_short Scanning Beam Proton Therapy versus Photon IMRT for Stage III Lung Cancer: Comparison of Dosimetry, Toxicity, and Outcomes
title_sort scanning beam proton therapy versus photon imrt for stage iii lung cancer: comparison of dosimetry, toxicity, and outcomes
topic Thoracic Cancer
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7276696/
https://www.ncbi.nlm.nih.gov/pubmed/32529138
http://dx.doi.org/10.1016/j.adro.2020.03.001
work_keys_str_mv AT zouzhenwei scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes
AT bowenstephenr scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes
AT thomashannahmt scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes
AT sasidharanbalukrishna scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes
AT renganramesh scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes
AT zengjing scanningbeamprotontherapyversusphotonimrtforstageiiilungcancercomparisonofdosimetrytoxicityandoutcomes