Cargando…

Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water

Freshwater green algae Chlorella vulgaris was selected as an adsorbent, and a simple, rapid, economical and environmentally friendly method for the detection of heavy metal Cd in water samples based on preconcentration with C. vulgaris combined with energy dispersive X-ray fluorescence (EDXRF) spect...

Descripción completa

Detalles Bibliográficos
Autores principales: Gan, Tingting, Zhao, Nanjing, Yin, Gaofang, Chen, Min, Wang, Xiang, Hua, Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7277290/
https://www.ncbi.nlm.nih.gov/pubmed/32537220
http://dx.doi.org/10.1098/rsos.200182
_version_ 1783543090063081472
author Gan, Tingting
Zhao, Nanjing
Yin, Gaofang
Chen, Min
Wang, Xiang
Hua, Hui
author_facet Gan, Tingting
Zhao, Nanjing
Yin, Gaofang
Chen, Min
Wang, Xiang
Hua, Hui
author_sort Gan, Tingting
collection PubMed
description Freshwater green algae Chlorella vulgaris was selected as an adsorbent, and a simple, rapid, economical and environmentally friendly method for the detection of heavy metal Cd in water samples based on preconcentration with C. vulgaris combined with energy dispersive X-ray fluorescence (EDXRF) spectrometry was proposed.  Chlorella vulgaris could directly and rapidly adsorb Cd(2+) without any pretreatment, and the maximum adsorption efficiency could be obtained when the contact time was 1 min with an optimal pH of 10. The obtained Cd-enriched thin samples after preconcentration with C. vulgaris by suction filtration of reaction solution had very good uniformity, which could be directly measured by EDXRF spectrometry, and the net integral fluorescence intensity of Cd Kα characteristic peak had a very good linear relationship with the initial concentration of Cd in the range of 0.703–74.957 µg ml(−1) with a correlation coefficient of 0.9979. When the Cd thin samples with a Cd-enriched region of 15.1 mm in diameter were formed by the developed preconcentration method with suction filtration of 10 ml reaction solution, the detection limit of this method was 0.0654 µg ml(−1), which was lower than the maximum allowable discharge concentration of Cd in various industrial wastewaters. The proposed method was simple to operate, and could effectively remove the influence of matrix effect of water samples and effectively improve the sensitivity and stability of EDXRF spectrometry directly detecting heavy metals in water samples, which was successfully applied to detect Cd in real water samples with satisfactory results, and the recoveries ranged from 94.80% to 116.94%. Moreover, this method can be applied to the rapid detection and early warning of excessive Cd in discharged industrial wastewaters. This work will provide a methodological basis for the development of rapid and online monitoring technology and instrument of heavy metal pollutants in water.
format Online
Article
Text
id pubmed-7277290
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society
record_format MEDLINE/PubMed
spelling pubmed-72772902020-06-11 Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water Gan, Tingting Zhao, Nanjing Yin, Gaofang Chen, Min Wang, Xiang Hua, Hui R Soc Open Sci Chemistry Freshwater green algae Chlorella vulgaris was selected as an adsorbent, and a simple, rapid, economical and environmentally friendly method for the detection of heavy metal Cd in water samples based on preconcentration with C. vulgaris combined with energy dispersive X-ray fluorescence (EDXRF) spectrometry was proposed.  Chlorella vulgaris could directly and rapidly adsorb Cd(2+) without any pretreatment, and the maximum adsorption efficiency could be obtained when the contact time was 1 min with an optimal pH of 10. The obtained Cd-enriched thin samples after preconcentration with C. vulgaris by suction filtration of reaction solution had very good uniformity, which could be directly measured by EDXRF spectrometry, and the net integral fluorescence intensity of Cd Kα characteristic peak had a very good linear relationship with the initial concentration of Cd in the range of 0.703–74.957 µg ml(−1) with a correlation coefficient of 0.9979. When the Cd thin samples with a Cd-enriched region of 15.1 mm in diameter were formed by the developed preconcentration method with suction filtration of 10 ml reaction solution, the detection limit of this method was 0.0654 µg ml(−1), which was lower than the maximum allowable discharge concentration of Cd in various industrial wastewaters. The proposed method was simple to operate, and could effectively remove the influence of matrix effect of water samples and effectively improve the sensitivity and stability of EDXRF spectrometry directly detecting heavy metals in water samples, which was successfully applied to detect Cd in real water samples with satisfactory results, and the recoveries ranged from 94.80% to 116.94%. Moreover, this method can be applied to the rapid detection and early warning of excessive Cd in discharged industrial wastewaters. This work will provide a methodological basis for the development of rapid and online monitoring technology and instrument of heavy metal pollutants in water. The Royal Society 2020-05-13 /pmc/articles/PMC7277290/ /pubmed/32537220 http://dx.doi.org/10.1098/rsos.200182 Text en © 2020 The Authors. http://creativecommons.org/licenses/by/4.0/ http://creativecommons.org/licenses/by/4.0/http://creativecommons.org/licenses/by/4.0/Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, provided the original author and source are credited.
spellingShingle Chemistry
Gan, Tingting
Zhao, Nanjing
Yin, Gaofang
Chen, Min
Wang, Xiang
Hua, Hui
Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title_full Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title_fullStr Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title_full_unstemmed Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title_short Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
title_sort preconcentration with chlorella vulgaris combined with energy dispersive x-ray fluorescence spectrometry for rapid determination of cd in water
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7277290/
https://www.ncbi.nlm.nih.gov/pubmed/32537220
http://dx.doi.org/10.1098/rsos.200182
work_keys_str_mv AT gantingting preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater
AT zhaonanjing preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater
AT yingaofang preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater
AT chenmin preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater
AT wangxiang preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater
AT huahui preconcentrationwithchlorellavulgariscombinedwithenergydispersivexrayfluorescencespectrometryforrapiddeterminationofcdinwater