Cargando…
Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy
In this paper, we present an architecture of a personalized glucose monitoring system (PGMS). PGMS consists of both invasive and non-invasive sensors on a single device. Initially, blood glucose is measured invasively and non-invasively, to train the machine learning models. Then, paired data and co...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7278000/ https://www.ncbi.nlm.nih.gov/pubmed/32392841 http://dx.doi.org/10.3390/diagnostics10050285 |
_version_ | 1783543249830412288 |
---|---|
author | Anand, Pradeep Kumar Shin, Dong Ryeol Memon, Mudasar Latif |
author_facet | Anand, Pradeep Kumar Shin, Dong Ryeol Memon, Mudasar Latif |
author_sort | Anand, Pradeep Kumar |
collection | PubMed |
description | In this paper, we present an architecture of a personalized glucose monitoring system (PGMS). PGMS consists of both invasive and non-invasive sensors on a single device. Initially, blood glucose is measured invasively and non-invasively, to train the machine learning models. Then, paired data and corresponding errors are divided scientifically into six different clusters based on blood glucose ranges as per the patient’s diabetic conditions. Each cluster is trained to build the unique error prediction model using an adaptive boosting (AdaBoost) algorithm. Later, these error prediction models undergo personalized calibration based on the patient’s characteristics. Once, the errors in predicted non-invasive values are within the acceptable error range, the device gets personalized for a patient to measure the blood glucose non-invasively. We verify PGMS on two different datasets. Performance analysis shows that the mean absolute relative difference (MARD) is reduced exceptionally to 7.3% and 7.1% for predicted values as compared to 25.4% and 18.4% for measured non-invasive glucose values. The Clarke error grid analysis (CEGA) plot for non-invasive predicted values shows 97% data in Zone A and 3% data in Zone B for dataset 1. Moreover, for dataset 2 results echoed with 98% and 2% in Zones A and B, respectively. |
format | Online Article Text |
id | pubmed-7278000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72780002020-06-12 Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy Anand, Pradeep Kumar Shin, Dong Ryeol Memon, Mudasar Latif Diagnostics (Basel) Article In this paper, we present an architecture of a personalized glucose monitoring system (PGMS). PGMS consists of both invasive and non-invasive sensors on a single device. Initially, blood glucose is measured invasively and non-invasively, to train the machine learning models. Then, paired data and corresponding errors are divided scientifically into six different clusters based on blood glucose ranges as per the patient’s diabetic conditions. Each cluster is trained to build the unique error prediction model using an adaptive boosting (AdaBoost) algorithm. Later, these error prediction models undergo personalized calibration based on the patient’s characteristics. Once, the errors in predicted non-invasive values are within the acceptable error range, the device gets personalized for a patient to measure the blood glucose non-invasively. We verify PGMS on two different datasets. Performance analysis shows that the mean absolute relative difference (MARD) is reduced exceptionally to 7.3% and 7.1% for predicted values as compared to 25.4% and 18.4% for measured non-invasive glucose values. The Clarke error grid analysis (CEGA) plot for non-invasive predicted values shows 97% data in Zone A and 3% data in Zone B for dataset 1. Moreover, for dataset 2 results echoed with 98% and 2% in Zones A and B, respectively. MDPI 2020-05-07 /pmc/articles/PMC7278000/ /pubmed/32392841 http://dx.doi.org/10.3390/diagnostics10050285 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Anand, Pradeep Kumar Shin, Dong Ryeol Memon, Mudasar Latif Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title | Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title_full | Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title_fullStr | Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title_full_unstemmed | Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title_short | Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy |
title_sort | adaptive boosting based personalized glucose monitoring system (pgms) for non-invasive blood glucose prediction with improved accuracy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7278000/ https://www.ncbi.nlm.nih.gov/pubmed/32392841 http://dx.doi.org/10.3390/diagnostics10050285 |
work_keys_str_mv | AT anandpradeepkumar adaptiveboostingbasedpersonalizedglucosemonitoringsystempgmsfornoninvasivebloodglucosepredictionwithimprovedaccuracy AT shindongryeol adaptiveboostingbasedpersonalizedglucosemonitoringsystempgmsfornoninvasivebloodglucosepredictionwithimprovedaccuracy AT memonmudasarlatif adaptiveboostingbasedpersonalizedglucosemonitoringsystempgmsfornoninvasivebloodglucosepredictionwithimprovedaccuracy |