Cargando…

The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis

BACKGROUND: Identifying coronary artery disease (CAD) in patients with end-stage renal disease (ESRD) is challenging. Adenosine stress native T1 mapping with cardiovascular magnetic resonance (CMR) may accurately detect obstructive CAD and microvascular dysfunction in the general population. This st...

Descripción completa

Detalles Bibliográficos
Autores principales: Poli, Federica E, Gulsin, Gaurav S, March, Daniel S, Abdelaty, Ahmed MSEK, Parke, Kelly S, Wormleighton, Joanne V, McCann, Gerry P, Burton, James O, Graham-Brown, Matthew PM
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7278072/
https://www.ncbi.nlm.nih.gov/pubmed/32507107
http://dx.doi.org/10.1186/s12968-020-00634-y
_version_ 1783543261314416640
author Poli, Federica E
Gulsin, Gaurav S
March, Daniel S
Abdelaty, Ahmed MSEK
Parke, Kelly S
Wormleighton, Joanne V
McCann, Gerry P
Burton, James O
Graham-Brown, Matthew PM
author_facet Poli, Federica E
Gulsin, Gaurav S
March, Daniel S
Abdelaty, Ahmed MSEK
Parke, Kelly S
Wormleighton, Joanne V
McCann, Gerry P
Burton, James O
Graham-Brown, Matthew PM
author_sort Poli, Federica E
collection PubMed
description BACKGROUND: Identifying coronary artery disease (CAD) in patients with end-stage renal disease (ESRD) is challenging. Adenosine stress native T1 mapping with cardiovascular magnetic resonance (CMR) may accurately detect obstructive CAD and microvascular dysfunction in the general population. This study assessed the feasibility and reliability of adenosine stress native T1 mapping in patients on haemodialysis. METHODS: The feasibility of undertaking rest and adenosine stress native T1 mapping using the single-shot Modified Look-Locker inversion recovery (MOLLI) sequence was assessed in 58 patients on maintenance haemodialysis using 3 T CMR. Ten patients underwent repeat stress CMR within 2 weeks for assessment of test-retest reliability of native T1, stress T1 and delta T1 (ΔT1). Interrater and intrarater agreement were assessed in 10 patients. Exploratory analyses were undertaken to assess associations between clinical variables and native T1 values in 51 patients on haemodialysis. RESULTS: Mean age of participants was 55 ± 15 years, 46 (79%) were male, and median dialysis vintage was 21 (8; 48) months. All patients completed the scan without complications. Mean native T1 rest, stress and ΔT1 were 1261 ± 57 ms, 1297 ± 50 ms and 2.9 ± 2.5%, respectively. Interrater and intrarater agreement of rest T1, stress T1 and ΔT1 were excellent, with intraclass correlation coefficients (ICC) > 0.9 for all. Test-retest reliability of rest and stress native T1 were excellent or good (CoV 1.2 and 1.5%; ICC, 0.79 and 0.69, respectively). Test-retest reliability of ΔT1 was moderate to poor (CoV 27.4%, ICC 0.55). On multivariate analysis, CAD, diabetes mellitus and resting native T1 time were independent determinants of ΔT1 (β = − 0.275, p = 0.019; β = − 0.297, p = 0.013; β = − 0.455; p < 0.001, respectively). CONCLUSIONS: Rest and adenosine stress native T1 mapping is feasible and well-tolerated amongst patients with ESRD on haemodialysis. Although rater agreement of the technique is excellent, test-retest reliability of ΔT1 is moderate to poor. Prospective studies should evaluate the relationship between this technique and established methods of CAD assessment and association with outcomes.
format Online
Article
Text
id pubmed-7278072
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72780722020-06-09 The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis Poli, Federica E Gulsin, Gaurav S March, Daniel S Abdelaty, Ahmed MSEK Parke, Kelly S Wormleighton, Joanne V McCann, Gerry P Burton, James O Graham-Brown, Matthew PM J Cardiovasc Magn Reson Research BACKGROUND: Identifying coronary artery disease (CAD) in patients with end-stage renal disease (ESRD) is challenging. Adenosine stress native T1 mapping with cardiovascular magnetic resonance (CMR) may accurately detect obstructive CAD and microvascular dysfunction in the general population. This study assessed the feasibility and reliability of adenosine stress native T1 mapping in patients on haemodialysis. METHODS: The feasibility of undertaking rest and adenosine stress native T1 mapping using the single-shot Modified Look-Locker inversion recovery (MOLLI) sequence was assessed in 58 patients on maintenance haemodialysis using 3 T CMR. Ten patients underwent repeat stress CMR within 2 weeks for assessment of test-retest reliability of native T1, stress T1 and delta T1 (ΔT1). Interrater and intrarater agreement were assessed in 10 patients. Exploratory analyses were undertaken to assess associations between clinical variables and native T1 values in 51 patients on haemodialysis. RESULTS: Mean age of participants was 55 ± 15 years, 46 (79%) were male, and median dialysis vintage was 21 (8; 48) months. All patients completed the scan without complications. Mean native T1 rest, stress and ΔT1 were 1261 ± 57 ms, 1297 ± 50 ms and 2.9 ± 2.5%, respectively. Interrater and intrarater agreement of rest T1, stress T1 and ΔT1 were excellent, with intraclass correlation coefficients (ICC) > 0.9 for all. Test-retest reliability of rest and stress native T1 were excellent or good (CoV 1.2 and 1.5%; ICC, 0.79 and 0.69, respectively). Test-retest reliability of ΔT1 was moderate to poor (CoV 27.4%, ICC 0.55). On multivariate analysis, CAD, diabetes mellitus and resting native T1 time were independent determinants of ΔT1 (β = − 0.275, p = 0.019; β = − 0.297, p = 0.013; β = − 0.455; p < 0.001, respectively). CONCLUSIONS: Rest and adenosine stress native T1 mapping is feasible and well-tolerated amongst patients with ESRD on haemodialysis. Although rater agreement of the technique is excellent, test-retest reliability of ΔT1 is moderate to poor. Prospective studies should evaluate the relationship between this technique and established methods of CAD assessment and association with outcomes. BioMed Central 2020-06-08 /pmc/articles/PMC7278072/ /pubmed/32507107 http://dx.doi.org/10.1186/s12968-020-00634-y Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Poli, Federica E
Gulsin, Gaurav S
March, Daniel S
Abdelaty, Ahmed MSEK
Parke, Kelly S
Wormleighton, Joanne V
McCann, Gerry P
Burton, James O
Graham-Brown, Matthew PM
The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title_full The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title_fullStr The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title_full_unstemmed The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title_short The reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance T1 mapping in patients on haemodialysis
title_sort reliability and feasibility of non-contrast adenosine stress cardiovascular magnetic resonance t1 mapping in patients on haemodialysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7278072/
https://www.ncbi.nlm.nih.gov/pubmed/32507107
http://dx.doi.org/10.1186/s12968-020-00634-y
work_keys_str_mv AT polifedericae thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT gulsingauravs thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT marchdaniels thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT abdelatyahmedmsek thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT parkekellys thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT wormleightonjoannev thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT mccanngerryp thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT burtonjameso thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT grahambrownmatthewpm thereliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT polifedericae reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT gulsingauravs reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT marchdaniels reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT abdelatyahmedmsek reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT parkekellys reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT wormleightonjoannev reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT mccanngerryp reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT burtonjameso reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis
AT grahambrownmatthewpm reliabilityandfeasibilityofnoncontrastadenosinestresscardiovascularmagneticresonancet1mappinginpatientsonhaemodialysis