Cargando…

Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems

AIMS: Point-of-care (POC) tests for influenza and respiratory syncytial virus (RSV) offer the potential to improve patient management and antimicrobial stewardship. Studies have focused on performance; however, no workflow assessments have been published comparing POC molecular tests. This study com...

Descripción completa

Detalles Bibliográficos
Autores principales: Young, Stephen, Phillips, Jamie, Griego-Fullbright, Christen, Wagner, Aaron, Jim, Patricia, Chaudhuri, Sheena, Tang, Shaowu, Sickler, Joanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7279563/
https://www.ncbi.nlm.nih.gov/pubmed/31826935
http://dx.doi.org/10.1136/jclinpath-2019-206242
_version_ 1783543589496684544
author Young, Stephen
Phillips, Jamie
Griego-Fullbright, Christen
Wagner, Aaron
Jim, Patricia
Chaudhuri, Sheena
Tang, Shaowu
Sickler, Joanna
author_facet Young, Stephen
Phillips, Jamie
Griego-Fullbright, Christen
Wagner, Aaron
Jim, Patricia
Chaudhuri, Sheena
Tang, Shaowu
Sickler, Joanna
author_sort Young, Stephen
collection PubMed
description AIMS: Point-of-care (POC) tests for influenza and respiratory syncytial virus (RSV) offer the potential to improve patient management and antimicrobial stewardship. Studies have focused on performance; however, no workflow assessments have been published comparing POC molecular tests. This study compared the Liat and ID Now systems workflow, to assist end-users in selecting an influenza and/or RSV POC test. METHODS: Staffing, walk-away and turnaround time (TAT) of the Liat and ID Now systems were determined using 40 nasopharyngeal samples, positive for influenza or RSV. The ID Now system requires separate tests for influenza and RSV, so parallel (two instruments) and sequential (one instrument) workflows were evaluated. RESULTS: The ID Now ranged 4.1–6.2 min for staffing, 1.9–10.9 min for walk-away and 6.4–15.8 min for TAT per result. The Liat ranged 1.1–1.8 min for staffing, 20.0–20.5 min for walk-away and 21.3–22.0 min for TAT. Mean walk-away time comprised 38.0% (influenza positive) and 68.1% (influenza negative) of TAT for ID Now and 93.7% (influenza/RSV) for Liat. The ID Now parallel workflow resulted in medians of 5.9 min for staffing, 9.7 min for walk-away and 15.6 min for TAT. Assuming prevalence of 20% influenza and 20% RSV, the ID Now sequential workflow resulted in medians of 9.4 min for staffing, 17.4 min for walk-away, and 27.1 min for TAT. CONCLUSIONS: The ID Now and Liat systems offer different workflow characteristics. Key considerations for implementation include value of both influenza and RSV results, clinical setting, staffing capacity, and instrument(s) placement.
format Online
Article
Text
id pubmed-7279563
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-72795632020-06-15 Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems Young, Stephen Phillips, Jamie Griego-Fullbright, Christen Wagner, Aaron Jim, Patricia Chaudhuri, Sheena Tang, Shaowu Sickler, Joanna J Clin Pathol Original Research AIMS: Point-of-care (POC) tests for influenza and respiratory syncytial virus (RSV) offer the potential to improve patient management and antimicrobial stewardship. Studies have focused on performance; however, no workflow assessments have been published comparing POC molecular tests. This study compared the Liat and ID Now systems workflow, to assist end-users in selecting an influenza and/or RSV POC test. METHODS: Staffing, walk-away and turnaround time (TAT) of the Liat and ID Now systems were determined using 40 nasopharyngeal samples, positive for influenza or RSV. The ID Now system requires separate tests for influenza and RSV, so parallel (two instruments) and sequential (one instrument) workflows were evaluated. RESULTS: The ID Now ranged 4.1–6.2 min for staffing, 1.9–10.9 min for walk-away and 6.4–15.8 min for TAT per result. The Liat ranged 1.1–1.8 min for staffing, 20.0–20.5 min for walk-away and 21.3–22.0 min for TAT. Mean walk-away time comprised 38.0% (influenza positive) and 68.1% (influenza negative) of TAT for ID Now and 93.7% (influenza/RSV) for Liat. The ID Now parallel workflow resulted in medians of 5.9 min for staffing, 9.7 min for walk-away and 15.6 min for TAT. Assuming prevalence of 20% influenza and 20% RSV, the ID Now sequential workflow resulted in medians of 9.4 min for staffing, 17.4 min for walk-away, and 27.1 min for TAT. CONCLUSIONS: The ID Now and Liat systems offer different workflow characteristics. Key considerations for implementation include value of both influenza and RSV results, clinical setting, staffing capacity, and instrument(s) placement. BMJ Publishing Group 2020-06 2019-12-11 /pmc/articles/PMC7279563/ /pubmed/31826935 http://dx.doi.org/10.1136/jclinpath-2019-206242 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Original Research
Young, Stephen
Phillips, Jamie
Griego-Fullbright, Christen
Wagner, Aaron
Jim, Patricia
Chaudhuri, Sheena
Tang, Shaowu
Sickler, Joanna
Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title_full Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title_fullStr Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title_full_unstemmed Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title_short Molecular point-of-care testing for influenza A/B and respiratory syncytial virus: comparison of workflow parameters for the ID Now and cobas Liat systems
title_sort molecular point-of-care testing for influenza a/b and respiratory syncytial virus: comparison of workflow parameters for the id now and cobas liat systems
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7279563/
https://www.ncbi.nlm.nih.gov/pubmed/31826935
http://dx.doi.org/10.1136/jclinpath-2019-206242
work_keys_str_mv AT youngstephen molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT phillipsjamie molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT griegofullbrightchristen molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT wagneraaron molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT jimpatricia molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT chaudhurisheena molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT tangshaowu molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems
AT sicklerjoanna molecularpointofcaretestingforinfluenzaabandrespiratorysyncytialviruscomparisonofworkflowparametersfortheidnowandcobasliatsystems