A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep

The development of novel biodegradable vascular grafts of a small diameter (<6 mm) is an unmet clinical need for patients requiring arterial replacement. Here we performed a pre-clinical study of new small-caliber biodegradable vascular grafts using a sheep model of carotid artery implantation. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Antonova, Larisa V., Mironov, Andrey V., Yuzhalin, Arseniy E., Krivkina, Evgeniya O., Shabaev, Amin R., Rezvova, Maria A., Tkachenko, Vadim O., Khanova, Mariam Yu., Sergeeva, Tatiana Yu., Krutitskiy, Sergei S., Barbarash, Leonid S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7280958/
https://www.ncbi.nlm.nih.gov/pubmed/32455730
http://dx.doi.org/10.3390/ph13050101
_version_ 1783543819343495168
author Antonova, Larisa V.
Mironov, Andrey V.
Yuzhalin, Arseniy E.
Krivkina, Evgeniya O.
Shabaev, Amin R.
Rezvova, Maria A.
Tkachenko, Vadim O.
Khanova, Mariam Yu.
Sergeeva, Tatiana Yu.
Krutitskiy, Sergei S.
Barbarash, Leonid S.
author_facet Antonova, Larisa V.
Mironov, Andrey V.
Yuzhalin, Arseniy E.
Krivkina, Evgeniya O.
Shabaev, Amin R.
Rezvova, Maria A.
Tkachenko, Vadim O.
Khanova, Mariam Yu.
Sergeeva, Tatiana Yu.
Krutitskiy, Sergei S.
Barbarash, Leonid S.
author_sort Antonova, Larisa V.
collection PubMed
description The development of novel biodegradable vascular grafts of a small diameter (<6 mm) is an unmet clinical need for patients requiring arterial replacement. Here we performed a pre-clinical study of new small-caliber biodegradable vascular grafts using a sheep model of carotid artery implantation. The 4 mm diameter vascular grafts were manufactured using a mix of polyhydroxybutyrate/valerate and polycaprolactone supplemented with growth factors VEGF, bFGF and SDF-1α (PHBV/PCL-GFmix) and additionally modified by a polymer hydrogel coating with incorporation of drugs heparin and iloprost (PHBV/PCL-GFmix(Hep/Ilo)). Animals with carotid artery autograft implantation and those implanted with clinically used GORE-TEX(®) grafts were used as control groups. We observed that 24 h following surgery, animals with carotid artery autograft implantation showed 87.5% patency, while all the PHBV/PCL-GFmix and GORE-TEX(®) grafts displayed thrombosis. PHBV/PCL-GFmix(Hep/Ilo) grafts demonstrated 62.5% patency 24 h following surgery and it had remained at 50% 1 year post-operation. All the PHBV/PCL grafts completely degraded less than 1 year following surgery and were replaced by de novo vasculature without evidence of calcification. On the other hand, GORE-TEX(®) grafts displayed substantial amounts of calcium deposits throughout graft tissues. Thus, here we report a potential clinical usefulness of PHBV/PCL grafts upon their additional modification by growth factors and drugs to promote endothelialization and reduce thrombogenicity.
format Online
Article
Text
id pubmed-7280958
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72809582020-06-15 A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep Antonova, Larisa V. Mironov, Andrey V. Yuzhalin, Arseniy E. Krivkina, Evgeniya O. Shabaev, Amin R. Rezvova, Maria A. Tkachenko, Vadim O. Khanova, Mariam Yu. Sergeeva, Tatiana Yu. Krutitskiy, Sergei S. Barbarash, Leonid S. Pharmaceuticals (Basel) Communication The development of novel biodegradable vascular grafts of a small diameter (<6 mm) is an unmet clinical need for patients requiring arterial replacement. Here we performed a pre-clinical study of new small-caliber biodegradable vascular grafts using a sheep model of carotid artery implantation. The 4 mm diameter vascular grafts were manufactured using a mix of polyhydroxybutyrate/valerate and polycaprolactone supplemented with growth factors VEGF, bFGF and SDF-1α (PHBV/PCL-GFmix) and additionally modified by a polymer hydrogel coating with incorporation of drugs heparin and iloprost (PHBV/PCL-GFmix(Hep/Ilo)). Animals with carotid artery autograft implantation and those implanted with clinically used GORE-TEX(®) grafts were used as control groups. We observed that 24 h following surgery, animals with carotid artery autograft implantation showed 87.5% patency, while all the PHBV/PCL-GFmix and GORE-TEX(®) grafts displayed thrombosis. PHBV/PCL-GFmix(Hep/Ilo) grafts demonstrated 62.5% patency 24 h following surgery and it had remained at 50% 1 year post-operation. All the PHBV/PCL grafts completely degraded less than 1 year following surgery and were replaced by de novo vasculature without evidence of calcification. On the other hand, GORE-TEX(®) grafts displayed substantial amounts of calcium deposits throughout graft tissues. Thus, here we report a potential clinical usefulness of PHBV/PCL grafts upon their additional modification by growth factors and drugs to promote endothelialization and reduce thrombogenicity. MDPI 2020-05-21 /pmc/articles/PMC7280958/ /pubmed/32455730 http://dx.doi.org/10.3390/ph13050101 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Antonova, Larisa V.
Mironov, Andrey V.
Yuzhalin, Arseniy E.
Krivkina, Evgeniya O.
Shabaev, Amin R.
Rezvova, Maria A.
Tkachenko, Vadim O.
Khanova, Mariam Yu.
Sergeeva, Tatiana Yu.
Krutitskiy, Sergei S.
Barbarash, Leonid S.
A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title_full A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title_fullStr A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title_full_unstemmed A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title_short A Brief Report on an Implantation of Small-Caliber Biodegradable Vascular Grafts in a Carotid Artery of the Sheep
title_sort brief report on an implantation of small-caliber biodegradable vascular grafts in a carotid artery of the sheep
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7280958/
https://www.ncbi.nlm.nih.gov/pubmed/32455730
http://dx.doi.org/10.3390/ph13050101
work_keys_str_mv AT antonovalarisav abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT mironovandreyv abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT yuzhalinarseniye abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT krivkinaevgeniyao abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT shabaevaminr abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT rezvovamariaa abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT tkachenkovadimo abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT khanovamariamyu abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT sergeevatatianayu abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT krutitskiysergeis abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT barbarashleonids abriefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT antonovalarisav briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT mironovandreyv briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT yuzhalinarseniye briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT krivkinaevgeniyao briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT shabaevaminr briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT rezvovamariaa briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT tkachenkovadimo briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT khanovamariamyu briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT sergeevatatianayu briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT krutitskiysergeis briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep
AT barbarashleonids briefreportonanimplantationofsmallcaliberbiodegradablevasculargraftsinacarotidarteryofthesheep