Cargando…
Optimization of impedance-measured reflux events in GORD utilizing acid exposure time
BACKGROUND: Combining impedance with pH monitoring improves the detection and characterization of gastro-oesophageal reflux (GOR), yet the two modalities frequently differ in GOR quantification. Ambulatory 24-h pH-impedance monitoring often reveals more significant oesophageal acid exposure than imp...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7281954/ https://www.ncbi.nlm.nih.gov/pubmed/32517709 http://dx.doi.org/10.1186/s12876-020-01321-z |
_version_ | 1783544031897190400 |
---|---|
author | Horton, Anthony J. Clayton, Steven B. |
author_facet | Horton, Anthony J. Clayton, Steven B. |
author_sort | Horton, Anthony J. |
collection | PubMed |
description | BACKGROUND: Combining impedance with pH monitoring improves the detection and characterization of gastro-oesophageal reflux (GOR), yet the two modalities frequently differ in GOR quantification. Ambulatory 24-h pH-impedance monitoring often reveals more significant oesophageal acid exposure than impedance-measured reflux activity in patients with symptomatic gastro-oesophageal reflux disease (GORD). The purpose of this study is to elucidate the discrepancies between these modalities by assessing the predictive accuracy of impedance compared to acid exposure standards. METHODS: A single-institution, retrospective review of sequential 24-h pH-impedance results of 72 patients with symptomatic GOR off anti-secretory therapy was conducted. Reflux events measured by impedance were stratified by patient position and compared to oesophageal acid exposure time (AET). Oesophageal AET limits for GORD detection were utilized as gold standards to generate serial receiver operator characteristics (ROC) curves to assess the sensitivity and specificity of current impedance GORD detection limits and identify optimized impedance standards based on area under the curve (AUC) analysis. RESULTS: Mean total AET time was 10.5% (± 9.9%), and 63.8% of patients had elevated AET. By impedance, median GOR frequency was 43 (IQR 21–68), and 22.2% exceeded conventional GOR frequency limits of normal. ROC curve analysis revealed the current impedance standard of > 73 GOR events has a sensitivity of 32.6% and specificity of 96.5% (AUC 0.74) for GORD detection. By AUC analysis, an impedance threshold of > 41 GOR events is optimal for GORD detection (sensitivity 69.6%, specificity 80.7%, AUC 0.83). CONCLUSION: Conventional impedance standards for abnormal GOR frequency are weakly sensitive for the detection of GORD, providing a possible explanation to discrepancies in AET and impedance interpretation. Lowering impedance-measured GOR frequency limits to > 41 optimizes sensitivity and specificity while increasing congruence between pH and impedance metrics. |
format | Online Article Text |
id | pubmed-7281954 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-72819542020-06-09 Optimization of impedance-measured reflux events in GORD utilizing acid exposure time Horton, Anthony J. Clayton, Steven B. BMC Gastroenterol Research Article BACKGROUND: Combining impedance with pH monitoring improves the detection and characterization of gastro-oesophageal reflux (GOR), yet the two modalities frequently differ in GOR quantification. Ambulatory 24-h pH-impedance monitoring often reveals more significant oesophageal acid exposure than impedance-measured reflux activity in patients with symptomatic gastro-oesophageal reflux disease (GORD). The purpose of this study is to elucidate the discrepancies between these modalities by assessing the predictive accuracy of impedance compared to acid exposure standards. METHODS: A single-institution, retrospective review of sequential 24-h pH-impedance results of 72 patients with symptomatic GOR off anti-secretory therapy was conducted. Reflux events measured by impedance were stratified by patient position and compared to oesophageal acid exposure time (AET). Oesophageal AET limits for GORD detection were utilized as gold standards to generate serial receiver operator characteristics (ROC) curves to assess the sensitivity and specificity of current impedance GORD detection limits and identify optimized impedance standards based on area under the curve (AUC) analysis. RESULTS: Mean total AET time was 10.5% (± 9.9%), and 63.8% of patients had elevated AET. By impedance, median GOR frequency was 43 (IQR 21–68), and 22.2% exceeded conventional GOR frequency limits of normal. ROC curve analysis revealed the current impedance standard of > 73 GOR events has a sensitivity of 32.6% and specificity of 96.5% (AUC 0.74) for GORD detection. By AUC analysis, an impedance threshold of > 41 GOR events is optimal for GORD detection (sensitivity 69.6%, specificity 80.7%, AUC 0.83). CONCLUSION: Conventional impedance standards for abnormal GOR frequency are weakly sensitive for the detection of GORD, providing a possible explanation to discrepancies in AET and impedance interpretation. Lowering impedance-measured GOR frequency limits to > 41 optimizes sensitivity and specificity while increasing congruence between pH and impedance metrics. BioMed Central 2020-06-09 /pmc/articles/PMC7281954/ /pubmed/32517709 http://dx.doi.org/10.1186/s12876-020-01321-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Horton, Anthony J. Clayton, Steven B. Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title | Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title_full | Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title_fullStr | Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title_full_unstemmed | Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title_short | Optimization of impedance-measured reflux events in GORD utilizing acid exposure time |
title_sort | optimization of impedance-measured reflux events in gord utilizing acid exposure time |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7281954/ https://www.ncbi.nlm.nih.gov/pubmed/32517709 http://dx.doi.org/10.1186/s12876-020-01321-z |
work_keys_str_mv | AT hortonanthonyj optimizationofimpedancemeasuredrefluxeventsingordutilizingacidexposuretime AT claytonstevenb optimizationofimpedancemeasuredrefluxeventsingordutilizingacidexposuretime |