Cargando…

Assisting Vascular Surgery with Smartphone Augmented Reality

Background Augmented reality is a technology that expands on image-guided surgery to allow intraoperative guidance and navigation. Augmented reality-assisted surgery (ARAS) has not been implemented in the vascular field yet. The wealth of sensors found on modern smartphones make them a promising pla...

Descripción completa

Detalles Bibliográficos
Autor principal: Aly, Omar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7282367/
https://www.ncbi.nlm.nih.gov/pubmed/32528759
http://dx.doi.org/10.7759/cureus.8020
_version_ 1783544121461309440
author Aly, Omar
author_facet Aly, Omar
author_sort Aly, Omar
collection PubMed
description Background Augmented reality is a technology that expands on image-guided surgery to allow intraoperative guidance and navigation. Augmented reality-assisted surgery (ARAS) has not been implemented in the vascular field yet. The wealth of sensors found on modern smartphones make them a promising platform for implementing vascular ARAS. However, current smartphone augmented reality platforms suffer from tracking instability, making them unsuitable for precise surgery. Novel algorithms need to be developed to tackle the stability and performance limitations of mobile phone augmented reality. Aim The primary aim was to develop an ARAS system utilizing low-cost smartphone hardware for vascular surgery. The second aim was to assess its performance by evaluating the stability of its tracking algorithms. Methods We designed an ARAS system utilizing standard optical tracking (SOT) and developed a novel tracking algorithm: hybrid gyroscopic and optical tracking (HGOT) for improved tracking stability. We evaluated the stability of both tracking algorithms using a phantom model and calculated tracking errors using root mean square error (RMSE).  Results The novel augmented reality system displayed a three-dimensional (3D) guidance model fused with the patient’s anatomy on a smartphone in real-time. The rotational tracking RMSE was 3.12 degrees for SOT and 0.091 degrees for HGOT. Positional tracking RMSE was 3.3 mm for SOT compared to 0.03 mm for HGOT. Comparing the stability of both tracking techniques showed HGOT to be significantly superior to SOT (p = 0.004). Conclusion We have developed a novel augmented reality system for vascular procedures. The development of HGOT has significantly increased the stability of a low-cost handheld augmented reality solution. 
format Online
Article
Text
id pubmed-7282367
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-72823672020-06-10 Assisting Vascular Surgery with Smartphone Augmented Reality Aly, Omar Cureus Cardiac/Thoracic/Vascular Surgery Background Augmented reality is a technology that expands on image-guided surgery to allow intraoperative guidance and navigation. Augmented reality-assisted surgery (ARAS) has not been implemented in the vascular field yet. The wealth of sensors found on modern smartphones make them a promising platform for implementing vascular ARAS. However, current smartphone augmented reality platforms suffer from tracking instability, making them unsuitable for precise surgery. Novel algorithms need to be developed to tackle the stability and performance limitations of mobile phone augmented reality. Aim The primary aim was to develop an ARAS system utilizing low-cost smartphone hardware for vascular surgery. The second aim was to assess its performance by evaluating the stability of its tracking algorithms. Methods We designed an ARAS system utilizing standard optical tracking (SOT) and developed a novel tracking algorithm: hybrid gyroscopic and optical tracking (HGOT) for improved tracking stability. We evaluated the stability of both tracking algorithms using a phantom model and calculated tracking errors using root mean square error (RMSE).  Results The novel augmented reality system displayed a three-dimensional (3D) guidance model fused with the patient’s anatomy on a smartphone in real-time. The rotational tracking RMSE was 3.12 degrees for SOT and 0.091 degrees for HGOT. Positional tracking RMSE was 3.3 mm for SOT compared to 0.03 mm for HGOT. Comparing the stability of both tracking techniques showed HGOT to be significantly superior to SOT (p = 0.004). Conclusion We have developed a novel augmented reality system for vascular procedures. The development of HGOT has significantly increased the stability of a low-cost handheld augmented reality solution.  Cureus 2020-05-08 /pmc/articles/PMC7282367/ /pubmed/32528759 http://dx.doi.org/10.7759/cureus.8020 Text en Copyright © 2020, Aly et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Aly, Omar
Assisting Vascular Surgery with Smartphone Augmented Reality
title Assisting Vascular Surgery with Smartphone Augmented Reality
title_full Assisting Vascular Surgery with Smartphone Augmented Reality
title_fullStr Assisting Vascular Surgery with Smartphone Augmented Reality
title_full_unstemmed Assisting Vascular Surgery with Smartphone Augmented Reality
title_short Assisting Vascular Surgery with Smartphone Augmented Reality
title_sort assisting vascular surgery with smartphone augmented reality
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7282367/
https://www.ncbi.nlm.nih.gov/pubmed/32528759
http://dx.doi.org/10.7759/cureus.8020
work_keys_str_mv AT alyomar assistingvascularsurgerywithsmartphoneaugmentedreality