Cylindrical IR-ATR Sensors for Process Analytics

Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitive surface of the element is a crucial issue. An im...

Descripción completa

Detalles Bibliográficos
Autores principales: Lambrecht, Armin, Bolwien, Carsten, Erb, Jochen, Fuhr, Hendrik, Sulz, Gerd
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7284823/
https://www.ncbi.nlm.nih.gov/pubmed/32455667
http://dx.doi.org/10.3390/s20102917
_version_ 1783544558182727680
author Lambrecht, Armin
Bolwien, Carsten
Erb, Jochen
Fuhr, Hendrik
Sulz, Gerd
author_facet Lambrecht, Armin
Bolwien, Carsten
Erb, Jochen
Fuhr, Hendrik
Sulz, Gerd
author_sort Lambrecht, Armin
collection PubMed
description Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitive surface of the element is a crucial issue. An important industrial application is the measurement of isocyanate concentrations. Isocyanates are necessary for the fabrication of polyurethane materials and are among the chemicals with the highest production volume worldwide. For process applications, narrowband photometers or MEMS spectrometers are more appropriate than the use of bulky FTIR instruments frequently encountered in a laboratory environment. Toluene diisocyanate (TDI) and hexamethylene diisocyanate (HDI) concentrations are measured with a planar ATR photometer setup. Using a miniature Fabry–Perot interferometer (FPI), trace concentrations below 100 ppm (m/m) are detected. By employing an ATR element of the cylindrical shape, sensors can be realized with a smooth surface ideally suited for an automatic cleaning system in a process environment. A laboratory setup with sapphire tubes as ATR elements for incorporation in a liquid flow system is described. Reflection and transmission configurations were investigated. Measurements with acetonitrile as a less toxic substitute showed that with cylindrical ATR sensors’ detection limits for isocyanate concentrations below 100 ppm (m/m) are feasible.
format Online
Article
Text
id pubmed-7284823
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72848232020-06-15 Cylindrical IR-ATR Sensors for Process Analytics Lambrecht, Armin Bolwien, Carsten Erb, Jochen Fuhr, Hendrik Sulz, Gerd Sensors (Basel) Article Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitive surface of the element is a crucial issue. An important industrial application is the measurement of isocyanate concentrations. Isocyanates are necessary for the fabrication of polyurethane materials and are among the chemicals with the highest production volume worldwide. For process applications, narrowband photometers or MEMS spectrometers are more appropriate than the use of bulky FTIR instruments frequently encountered in a laboratory environment. Toluene diisocyanate (TDI) and hexamethylene diisocyanate (HDI) concentrations are measured with a planar ATR photometer setup. Using a miniature Fabry–Perot interferometer (FPI), trace concentrations below 100 ppm (m/m) are detected. By employing an ATR element of the cylindrical shape, sensors can be realized with a smooth surface ideally suited for an automatic cleaning system in a process environment. A laboratory setup with sapphire tubes as ATR elements for incorporation in a liquid flow system is described. Reflection and transmission configurations were investigated. Measurements with acetonitrile as a less toxic substitute showed that with cylindrical ATR sensors’ detection limits for isocyanate concentrations below 100 ppm (m/m) are feasible. MDPI 2020-05-21 /pmc/articles/PMC7284823/ /pubmed/32455667 http://dx.doi.org/10.3390/s20102917 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lambrecht, Armin
Bolwien, Carsten
Erb, Jochen
Fuhr, Hendrik
Sulz, Gerd
Cylindrical IR-ATR Sensors for Process Analytics
title Cylindrical IR-ATR Sensors for Process Analytics
title_full Cylindrical IR-ATR Sensors for Process Analytics
title_fullStr Cylindrical IR-ATR Sensors for Process Analytics
title_full_unstemmed Cylindrical IR-ATR Sensors for Process Analytics
title_short Cylindrical IR-ATR Sensors for Process Analytics
title_sort cylindrical ir-atr sensors for process analytics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7284823/
https://www.ncbi.nlm.nih.gov/pubmed/32455667
http://dx.doi.org/10.3390/s20102917
work_keys_str_mv AT lambrechtarmin cylindricaliratrsensorsforprocessanalytics
AT bolwiencarsten cylindricaliratrsensorsforprocessanalytics
AT erbjochen cylindricaliratrsensorsforprocessanalytics
AT fuhrhendrik cylindricaliratrsensorsforprocessanalytics
AT sulzgerd cylindricaliratrsensorsforprocessanalytics