Cargando…

Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods

Polar motion (PM) has a close relation to the Earth’s structure and composition, seasonal changes of the atmosphere and oceans, storage of waters, etc. As one of the four major space geodetic techniques, doppler orbitography and radiopositioning integrated by satellite (DORIS) is a mature technique...

Descripción completa

Detalles Bibliográficos
Autores principales: Kong, Qiaoli, Zhang, Linggang, Han, Litao, Guo, Jinyun, Zhang, Dezhi, Fang, Wenhao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7284962/
https://www.ncbi.nlm.nih.gov/pubmed/32429329
http://dx.doi.org/10.3390/s20102823
_version_ 1783544589987086336
author Kong, Qiaoli
Zhang, Linggang
Han, Litao
Guo, Jinyun
Zhang, Dezhi
Fang, Wenhao
author_facet Kong, Qiaoli
Zhang, Linggang
Han, Litao
Guo, Jinyun
Zhang, Dezhi
Fang, Wenhao
author_sort Kong, Qiaoli
collection PubMed
description Polar motion (PM) has a close relation to the Earth’s structure and composition, seasonal changes of the atmosphere and oceans, storage of waters, etc. As one of the four major space geodetic techniques, doppler orbitography and radiopositioning integrated by satellite (DORIS) is a mature technique that can monitor PM through precise ground station positioning. There are few articles that have analyzed the PM series derived by the DORIS solution in detail. The aim of this research was to assess the PM time-series based on the DORIS solution, to better capture the time-series. In this paper, Fourier fast transform (FFT) and singular spectrum analysis (SSA) were applied to analyze the 25 years of PM time-series solved by DORIS observation from January 1993 to January 2018, then accurately separate the trend terms and periodic signals, and finally precisely reconstruct the main components. To evaluate the PM time-series derived from DORIS, they were compared with those obtained from EOP 14 C04 (IAU2000). The results showed that the RMSs of the differences in PM between them were 1.594 mas and 1.465 mas in the X and Y directions, respectively. Spectrum analysis using FFT showed that the period of annual wobble was 0.998 years and that of the Chandler wobble was 1.181 years. During the SSA process, after singular value decomposition (SVD), the time-series was reconstructed using the eigenvalues and corresponding eigenvectors, and the results indicated that the trend term, annual wobble, and Chandler wobble components were accurately decomposed and reconstructed, and the component reconstruction results had a precision of 3.858 and 2.387 mas in the X and Y directions, respectively. In addition, the tests also gave reasonable explanations of the phenomena of peaks of differences between the PM parameters derived from DORIS and EOP 14 C04, trend terms, the Chandler wobble, and other signals detected by the SSA and FFT. This research will help the assessment and explanation of PM time-series and will offer a good method for the prediction of pole shifts.
format Online
Article
Text
id pubmed-7284962
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72849622020-06-15 Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods Kong, Qiaoli Zhang, Linggang Han, Litao Guo, Jinyun Zhang, Dezhi Fang, Wenhao Sensors (Basel) Article Polar motion (PM) has a close relation to the Earth’s structure and composition, seasonal changes of the atmosphere and oceans, storage of waters, etc. As one of the four major space geodetic techniques, doppler orbitography and radiopositioning integrated by satellite (DORIS) is a mature technique that can monitor PM through precise ground station positioning. There are few articles that have analyzed the PM series derived by the DORIS solution in detail. The aim of this research was to assess the PM time-series based on the DORIS solution, to better capture the time-series. In this paper, Fourier fast transform (FFT) and singular spectrum analysis (SSA) were applied to analyze the 25 years of PM time-series solved by DORIS observation from January 1993 to January 2018, then accurately separate the trend terms and periodic signals, and finally precisely reconstruct the main components. To evaluate the PM time-series derived from DORIS, they were compared with those obtained from EOP 14 C04 (IAU2000). The results showed that the RMSs of the differences in PM between them were 1.594 mas and 1.465 mas in the X and Y directions, respectively. Spectrum analysis using FFT showed that the period of annual wobble was 0.998 years and that of the Chandler wobble was 1.181 years. During the SSA process, after singular value decomposition (SVD), the time-series was reconstructed using the eigenvalues and corresponding eigenvectors, and the results indicated that the trend term, annual wobble, and Chandler wobble components were accurately decomposed and reconstructed, and the component reconstruction results had a precision of 3.858 and 2.387 mas in the X and Y directions, respectively. In addition, the tests also gave reasonable explanations of the phenomena of peaks of differences between the PM parameters derived from DORIS and EOP 14 C04, trend terms, the Chandler wobble, and other signals detected by the SSA and FFT. This research will help the assessment and explanation of PM time-series and will offer a good method for the prediction of pole shifts. MDPI 2020-05-16 /pmc/articles/PMC7284962/ /pubmed/32429329 http://dx.doi.org/10.3390/s20102823 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kong, Qiaoli
Zhang, Linggang
Han, Litao
Guo, Jinyun
Zhang, Dezhi
Fang, Wenhao
Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title_full Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title_fullStr Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title_full_unstemmed Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title_short Analysis of 25 Years of Polar Motion Derived from the DORIS Space Geodetic Technique Using FFT and SSA Methods
title_sort analysis of 25 years of polar motion derived from the doris space geodetic technique using fft and ssa methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7284962/
https://www.ncbi.nlm.nih.gov/pubmed/32429329
http://dx.doi.org/10.3390/s20102823
work_keys_str_mv AT kongqiaoli analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods
AT zhanglinggang analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods
AT hanlitao analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods
AT guojinyun analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods
AT zhangdezhi analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods
AT fangwenhao analysisof25yearsofpolarmotionderivedfromthedorisspacegeodetictechniqueusingfftandssamethods