Cargando…

A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor

The foot arch index is an important index to evaluate the health of human feet and the biomechanics line, aiming at addressing the shortcomings of the low efficiency and slow speed of manual foot arch index measurement; in this work, an automatic foot arch index measurement method based on a flexibl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Tao, Yu, Zhiyong, Wang, Jin, Lu, Guodong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7285023/
https://www.ncbi.nlm.nih.gov/pubmed/32443736
http://dx.doi.org/10.3390/s20102892
_version_ 1783544603178172416
author Zheng, Tao
Yu, Zhiyong
Wang, Jin
Lu, Guodong
author_facet Zheng, Tao
Yu, Zhiyong
Wang, Jin
Lu, Guodong
author_sort Zheng, Tao
collection PubMed
description The foot arch index is an important index to evaluate the health of human feet and the biomechanics line, aiming at addressing the shortcomings of the low efficiency and slow speed of manual foot arch index measurement; in this work, an automatic foot arch index measurement method based on a flexible membrane pressure sensor was proposed. The distribution of plantar pressure data was obtained from the flexible membrane pressure sensor and converted into a digital image. The 8-neighborhood correlation pixel method was proposed to remove the interference of isolated noise points. In order to remove the toes’ data without affecting the foot sole data, the row element association algorithm was proposed. The front and back endpoints of the foot were automatically located to obtain the foot length, and the foot arch index was also automatically obtained based on the foot arch pressure area. Whether it was a high arch foot, flat foot or normal foot, the method proposed in this paper could accurately and quickly distinguish them. The prototype was developed, and its feasibility and validity were verified by a series of tests.
format Online
Article
Text
id pubmed-7285023
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72850232020-06-15 A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor Zheng, Tao Yu, Zhiyong Wang, Jin Lu, Guodong Sensors (Basel) Article The foot arch index is an important index to evaluate the health of human feet and the biomechanics line, aiming at addressing the shortcomings of the low efficiency and slow speed of manual foot arch index measurement; in this work, an automatic foot arch index measurement method based on a flexible membrane pressure sensor was proposed. The distribution of plantar pressure data was obtained from the flexible membrane pressure sensor and converted into a digital image. The 8-neighborhood correlation pixel method was proposed to remove the interference of isolated noise points. In order to remove the toes’ data without affecting the foot sole data, the row element association algorithm was proposed. The front and back endpoints of the foot were automatically located to obtain the foot length, and the foot arch index was also automatically obtained based on the foot arch pressure area. Whether it was a high arch foot, flat foot or normal foot, the method proposed in this paper could accurately and quickly distinguish them. The prototype was developed, and its feasibility and validity were verified by a series of tests. MDPI 2020-05-20 /pmc/articles/PMC7285023/ /pubmed/32443736 http://dx.doi.org/10.3390/s20102892 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zheng, Tao
Yu, Zhiyong
Wang, Jin
Lu, Guodong
A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title_full A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title_fullStr A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title_full_unstemmed A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title_short A New Automatic Foot Arch Index Measurement Method Based on a Flexible Membrane Pressure Sensor
title_sort new automatic foot arch index measurement method based on a flexible membrane pressure sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7285023/
https://www.ncbi.nlm.nih.gov/pubmed/32443736
http://dx.doi.org/10.3390/s20102892
work_keys_str_mv AT zhengtao anewautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT yuzhiyong anewautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT wangjin anewautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT luguodong anewautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT zhengtao newautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT yuzhiyong newautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT wangjin newautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor
AT luguodong newautomaticfootarchindexmeasurementmethodbasedonaflexiblemembranepressuresensor