Cargando…

Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom

We report on the development of a method for measuring the permittivity and conductivity of fluids inside a sealed tank (or a pipe) by using an embedded coaxial probe. Permittivity and conductivity in the frequency range 600 MHz to 6 GHz are determined from measurements of a complex reflection coeff...

Descripción completa

Detalles Bibliográficos
Autores principales: Gregory, Andrew P., Quéléver, Kristell, Allal, Djamel, Jawad, Ourouk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7285322/
https://www.ncbi.nlm.nih.gov/pubmed/32456139
http://dx.doi.org/10.3390/s20102956
_version_ 1783544673364606976
author Gregory, Andrew P.
Quéléver, Kristell
Allal, Djamel
Jawad, Ourouk
author_facet Gregory, Andrew P.
Quéléver, Kristell
Allal, Djamel
Jawad, Ourouk
author_sort Gregory, Andrew P.
collection PubMed
description We report on the development of a method for measuring the permittivity and conductivity of fluids inside a sealed tank (or a pipe) by using an embedded coaxial probe. Permittivity and conductivity in the frequency range 600 MHz to 6 GHz are determined from measurements of a complex reflection coefficient by using a vector network analyser (VNA) that is connected to the embedded probe via a coaxial cable. Substitution methods for calibration of an inaccessible probe are studied in this paper. These require the VNA with attached cable to be calibrated prior to connecting the cable to the embedded coaxial probe. Measurement of permittivity and conductivity of fluids inside sealed tanks and pipes is needed for monitoring industrial processes, such as fermentation. The authors’ requirement, however, was to allow monitoring of a tissue-equivalent liquid that is contained inside a sealed tank. This tank is a component of a commercial system for rapid, multiple-band measurement of the specific absorption rate (SAR) of mobile phone handsets. Monitoring of permittivity and conductivity is needed to ensure compliance with international standards for SAR measurement. The paper also presents data for a new broadband (600 MHz to 6 GHz) tissue-equivalent liquid that is based on an oil-in-water emulsion. It is demonstrated that over an extended period of time, the liquid is stable, and an embedded coaxial probe enables its properties to be monitored with the required accuracy.
format Online
Article
Text
id pubmed-7285322
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72853222020-06-15 Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom Gregory, Andrew P. Quéléver, Kristell Allal, Djamel Jawad, Ourouk Sensors (Basel) Article We report on the development of a method for measuring the permittivity and conductivity of fluids inside a sealed tank (or a pipe) by using an embedded coaxial probe. Permittivity and conductivity in the frequency range 600 MHz to 6 GHz are determined from measurements of a complex reflection coefficient by using a vector network analyser (VNA) that is connected to the embedded probe via a coaxial cable. Substitution methods for calibration of an inaccessible probe are studied in this paper. These require the VNA with attached cable to be calibrated prior to connecting the cable to the embedded coaxial probe. Measurement of permittivity and conductivity of fluids inside sealed tanks and pipes is needed for monitoring industrial processes, such as fermentation. The authors’ requirement, however, was to allow monitoring of a tissue-equivalent liquid that is contained inside a sealed tank. This tank is a component of a commercial system for rapid, multiple-band measurement of the specific absorption rate (SAR) of mobile phone handsets. Monitoring of permittivity and conductivity is needed to ensure compliance with international standards for SAR measurement. The paper also presents data for a new broadband (600 MHz to 6 GHz) tissue-equivalent liquid that is based on an oil-in-water emulsion. It is demonstrated that over an extended period of time, the liquid is stable, and an embedded coaxial probe enables its properties to be monitored with the required accuracy. MDPI 2020-05-23 /pmc/articles/PMC7285322/ /pubmed/32456139 http://dx.doi.org/10.3390/s20102956 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gregory, Andrew P.
Quéléver, Kristell
Allal, Djamel
Jawad, Ourouk
Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title_full Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title_fullStr Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title_full_unstemmed Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title_short Validation of a Broadband Tissue-Equivalent Liquid for SAR Measurement and Monitoring of Its Dielectric Properties for Use in a Sealed Phantom
title_sort validation of a broadband tissue-equivalent liquid for sar measurement and monitoring of its dielectric properties for use in a sealed phantom
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7285322/
https://www.ncbi.nlm.nih.gov/pubmed/32456139
http://dx.doi.org/10.3390/s20102956
work_keys_str_mv AT gregoryandrewp validationofabroadbandtissueequivalentliquidforsarmeasurementandmonitoringofitsdielectricpropertiesforuseinasealedphantom
AT queleverkristell validationofabroadbandtissueequivalentliquidforsarmeasurementandmonitoringofitsdielectricpropertiesforuseinasealedphantom
AT allaldjamel validationofabroadbandtissueequivalentliquidforsarmeasurementandmonitoringofitsdielectricpropertiesforuseinasealedphantom
AT jawadourouk validationofabroadbandtissueequivalentliquidforsarmeasurementandmonitoringofitsdielectricpropertiesforuseinasealedphantom