A plan template‐based automation solution using a commercial treatment planning system

PURPOSE: The purpose of this study was to develop an auto‐planning platform to be interfaced with a commercial treatment planning system (TPS). The main goal was to obtain robust and high‐quality plans for different anatomic sites and various dosimetric requirements. METHODS: Monaco (Elekta, St. Lou...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Xiaotian, Quan, Hong, Zhao, Bo, Zhou, Wing, Chen, Charles, Chen, Yan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7286016/
https://www.ncbi.nlm.nih.gov/pubmed/32180351
http://dx.doi.org/10.1002/acm2.12848
_version_ 1783544804289806336
author Huang, Xiaotian
Quan, Hong
Zhao, Bo
Zhou, Wing
Chen, Charles
Chen, Yan
author_facet Huang, Xiaotian
Quan, Hong
Zhao, Bo
Zhou, Wing
Chen, Charles
Chen, Yan
author_sort Huang, Xiaotian
collection PubMed
description PURPOSE: The purpose of this study was to develop an auto‐planning platform to be interfaced with a commercial treatment planning system (TPS). The main goal was to obtain robust and high‐quality plans for different anatomic sites and various dosimetric requirements. METHODS: Monaco (Elekta, St. Louis, US) was the TPS in this work. All input parameters for inverse planning could be defined in a plan template inside Monaco. A software tool called Robot Framework was used to launch auto‐planning trials with updated plan templates. The template modifier external to Monaco was the major component of our auto‐planning platform. For current implementation, it was a rule‐based system that mimics the trial‐and‐error process of an experienced planner. A template was automatically updated by changing the optimization constraints based on dosimetric evaluation of the plan obtained in the previous trial, along with the data of the iterative optimization extracted from Monaco. Treatment plans generated by Monaco with all plan evaluation criteria satisfied were considered acceptable, and such plans would be saved for further evaluation by clinicians. The auto‐planning platform was validated for 10 prostate and 10 head‐and‐neck cases in comparison with clinical plans generated by experienced planners. RESULTS: The performance and robustness of our auto‐planning platform was tested with clinical cases of prostate and head and neck treatment. For prostate cases, automatically generated plans had very similar plan quality with the clinical plans, and the bladder volume receiving 62.5 Gy, 50 Gy, and 40 Gy in auto‐plans was reduced by 1%, 3%, and 5%, respectively. For head and neck cases, auto‐plans had better conformity with reduced dose to the normal structures but slightly higher dose inhomogeneity in the target volume. Remarkably, the maximum dose in the spinal cord and brain stem was reduced by more than 3.5 Gy in auto‐plans. Fluence map optimization only with less than 30 trials was adequate to generate acceptable plans, and subsequent optimization for final plans was completed by Monaco without further intervention. The plan quality was weakly dependent on the parameter selection in the initial template and the choices of the step sizes for changing the constraint values. CONCLUSION: An automated planning platform to interface with Monaco was developed, and our reported tests showed preliminary results for prostate and head and neck cases.
format Online
Article
Text
id pubmed-7286016
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-72860162020-06-11 A plan template‐based automation solution using a commercial treatment planning system Huang, Xiaotian Quan, Hong Zhao, Bo Zhou, Wing Chen, Charles Chen, Yan J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The purpose of this study was to develop an auto‐planning platform to be interfaced with a commercial treatment planning system (TPS). The main goal was to obtain robust and high‐quality plans for different anatomic sites and various dosimetric requirements. METHODS: Monaco (Elekta, St. Louis, US) was the TPS in this work. All input parameters for inverse planning could be defined in a plan template inside Monaco. A software tool called Robot Framework was used to launch auto‐planning trials with updated plan templates. The template modifier external to Monaco was the major component of our auto‐planning platform. For current implementation, it was a rule‐based system that mimics the trial‐and‐error process of an experienced planner. A template was automatically updated by changing the optimization constraints based on dosimetric evaluation of the plan obtained in the previous trial, along with the data of the iterative optimization extracted from Monaco. Treatment plans generated by Monaco with all plan evaluation criteria satisfied were considered acceptable, and such plans would be saved for further evaluation by clinicians. The auto‐planning platform was validated for 10 prostate and 10 head‐and‐neck cases in comparison with clinical plans generated by experienced planners. RESULTS: The performance and robustness of our auto‐planning platform was tested with clinical cases of prostate and head and neck treatment. For prostate cases, automatically generated plans had very similar plan quality with the clinical plans, and the bladder volume receiving 62.5 Gy, 50 Gy, and 40 Gy in auto‐plans was reduced by 1%, 3%, and 5%, respectively. For head and neck cases, auto‐plans had better conformity with reduced dose to the normal structures but slightly higher dose inhomogeneity in the target volume. Remarkably, the maximum dose in the spinal cord and brain stem was reduced by more than 3.5 Gy in auto‐plans. Fluence map optimization only with less than 30 trials was adequate to generate acceptable plans, and subsequent optimization for final plans was completed by Monaco without further intervention. The plan quality was weakly dependent on the parameter selection in the initial template and the choices of the step sizes for changing the constraint values. CONCLUSION: An automated planning platform to interface with Monaco was developed, and our reported tests showed preliminary results for prostate and head and neck cases. John Wiley and Sons Inc. 2020-03-16 /pmc/articles/PMC7286016/ /pubmed/32180351 http://dx.doi.org/10.1002/acm2.12848 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Huang, Xiaotian
Quan, Hong
Zhao, Bo
Zhou, Wing
Chen, Charles
Chen, Yan
A plan template‐based automation solution using a commercial treatment planning system
title A plan template‐based automation solution using a commercial treatment planning system
title_full A plan template‐based automation solution using a commercial treatment planning system
title_fullStr A plan template‐based automation solution using a commercial treatment planning system
title_full_unstemmed A plan template‐based automation solution using a commercial treatment planning system
title_short A plan template‐based automation solution using a commercial treatment planning system
title_sort plan template‐based automation solution using a commercial treatment planning system
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7286016/
https://www.ncbi.nlm.nih.gov/pubmed/32180351
http://dx.doi.org/10.1002/acm2.12848
work_keys_str_mv AT huangxiaotian aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT quanhong aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT zhaobo aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT zhouwing aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT chencharles aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT chenyan aplantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT huangxiaotian plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT quanhong plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT zhaobo plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT zhouwing plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT chencharles plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem
AT chenyan plantemplatebasedautomationsolutionusingacommercialtreatmentplanningsystem